Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pectus excavatum
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper discusses a new Implant Safety Tool, used to assess the safety of patients with metal implants exposed to radio-frequency (RF) fields. This specialist tool is discussed on the example of pectus patients with titanium bar-implant inserted during the minimally invasive Nuss procedure. The authors created a 3D realistic model of a 34-year-old male patient with a Nuss bar-implant. A numerical analysis based on the finite-difference time-domain (FDTD) method was performed for a far field source in the form of a plane wave with the frequency of 64 MHz, which corresponds to the RF exposure generated by MRI devices at 1.5 T. The obtained results allow concluding that the concave Nuss bar-implant poses no risk during environmental and occupational RF field exposures.
EN
The paper discusses results of experimental research involving new generation of plate stabilizers used for the treatment of deformation of the front chest wall. Previous clinical monitoring revealed instances of minimal rotation, which caused destabilization of the anastomosis and pain in patients. In order to prevent this, transverse stabilizing plates were introduced to the structure of the stabilizer. The new structure of stabilizers was tested using two specially prepared research posts: 1 – which enables fastening of the plate stabilizers to a platform simulating human ribs, 2 – using a pig chest, to which plates were fastened according to the stabilization conditions in the stabilizer–chest structure. The tests recorded displacement values in selected areas of the plates in response to applied loading forces.
3
Content available The finite element model of the human rib cage
EN
In the paper, finite element analysis of the rib cage model is applied to recognize stress distributions and to determine the rate of bone fractures (especially for pathologically changed bones). Two thorax models are considered and the role of the implant is illustrated and discussed. The simulation result shows a good agreement wit h the cadaver test data.
PL
Artykuł przedstawia analizę wytrzymałościową klatki piersiowej metodą elementów skończonych. Przeprowadzone badania pozwalają na poznanie rozkładu naprężeń i odkształceń w klatce piersiowej oraz na ocenę miejsc najbardziej narażonych na złamania. Rozpatrzono dwa modele klatki piersiowej: pierwszy człowieka zdrowego oraz drugi człowieka po chirurgicznej operacji lejkowatej klatki piersiowej z zastosowaniem implantu. Opisano wpływ implantu na wytrzymałość klatki piersiowej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.