Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  peak load
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The subject matter of coefficient factors is not a frequent object of analysis in the scientific literature. However, because of the use of this term in engineering tasks and because of the constantly changing manner of energy use (resulting from the dissemination of new appliances), there is a need for current analysis and possible revision of the approach based on coefficient factors. The aim of the paper is to draw attention to the problem of the need to update these coefficients and compare currently recommended values of this coefficient in Poland. The coincidence factor method is based on two parameters: coefficient factor as a function of the number of users and base value (average peak power of one user). Both parameters should be revised over time.
PL
Zagadnienie wyznaczania współczynników jednoczesności szczytów obciążeń użytkowanej mocy nie jest częstym przedmiotem analizy w literaturze naukowej. Ze względu na wykorzystywanie metody opartej na tych współczynnikach w zadaniach inżynierskich oraz ze względu na zmiany w sposobie użytkowania energii przez odbiorców, istnieje potrzeba bieżącej analizy i ewentualnej rewizji odpowiednich wartości. Metoda współczynnika jednoczesności opiera się na dwóch parametrach: współczynniku w funkcji liczby użytkowników oraz mocy szczytowej jednego użytkownika. Oba te parametry powinny podlegać aktualizacji w obowiązujących standardach. Celem artykułu jest zwrócenie uwagi na problem konieczności aktualizacji współczynników oraz porównanie obecnie zalecanych w Polsce ich wartości.
2
EN
The increase in energy consumption and energy bills in Jordan have been escalating rapidly, which requires a special concern as a large percent of the energy is imported. The need for the reducing peak demand of the distribution network is essential to decrease the overall electricity generation cost. This study was aimed at presenting a model for a home that manages its energy consumption, and the maximum savings possible if the load shifting to off-peak times was applied. It also introduced a tariff that is more concerned in time of use rather than consumption only. The power consumption profile is collected for a sample house. The profile for a week was registered and graphed. The pricing suggested was calculated per day. Moreover, some samples applied worldwide were discussed to find a suitable model. It was found that a saving rate of 16% is achievable if the time of use charge is applied. Additionally, a peak load reduction of 3.5 kWH average per day (in the peak hours) is possible.
3
Content available remote Experimental study of spot weld parameters in resistance spot welding process
EN
Resistance spot welding is a comparatively clean and efficient welding process that is widely used in sheet metal joining. This process involves electrical, thermal and mechanical interactions. Resistance spot welding primarily takes place by localized melting at the inter-face of the sheets followed by its quick solidification under sequential control of water cooled electrode pressure and ?ow of required electric current for certain duration. In this experimental work the tensile tests and the spot weld diameter were studied. The objectives of this analysis is to understand the physics of the process and to show the influence of the electrical current, weld time and the type material in resistance spot welding process.
PL
Jednym ze sposobów poprawy elastyczności bloków energetycznych pracujących jako podszczytowe jest wykorzystanie akumulacji ciepła w układzie parowo-wodnym. Układy z zasobnikami wody zasilającej zapewniają stabilne warunki pracy kotła przy pracy elektrowni z obciążeniami elektrycznymi różnymi od znamionowego. Pozwala to na zwiększenie produkcji elektryczności w szczycie obciążenia systemu elektroenergetycznego i tym samym poprawia ekonomikę produkcji energii elektrycznej w blokach węglowych. W czasie doliny w systemie elektroenergetycznym lub obniżonego lokalnie zapotrzebowania na energię elektryczną zmniejsza się strumień pary dopływającej do skraplacza turbiny, a zwiększają się strumienie pary z upustów regeneracji niskoprężnej, które wykorzystuje się do podgrzewania zimnej wody zasilającej zmagazynowanej w dolnej części zasobnika. Podgrzaną wodę zasilającą gromadzi się w górnej części zasobnika. W okresie szczytu w systemie elektroenergetycznym lub zwiększonego lokalnie zapotrzebowania na elektryczność, część (lub całość) regeneracji niskoprężnej może być zamknięta, a podgrzana woda zasilająca jest pozyskiwana poprzez rozładowanie zasobników. W efekcie uzyskuje się zwiększenie produkcji szczytowej energii elektrycznej.
EN
One of the methods to improve flexibility of power units working as intermediate-load ones is heat storage application in a steam and water system. Such systems equipped with feed water storage tanks ensure stable operational conditions of a boiler when a power plant is working with loads different from the rated one. This allows to increase the production of electricity during peak loads and as a result to improve economics of coal-fired power plants. During off-peak loads of a power system or a local power demand decrease the steam flux to a condenser is reduced while the regenerative steam fluxes are increased. This way the cold feed water from the bottom part of a heat storage tank is heated up and the preheated water is then accumulated in the top part of the heat storage. During peak loads or a local power demand increase the whole (or a part) of the low-pressure regenerative system can be closed and the preheated water is transported from the heat storage to a feed water tank. As a result an increase in a peak load electricity production can be achieved.
EN
DSR resources able to participate effectively in peak demand balancing in Poland become necessary because of the predicted lack of generation adequacy. The most difficult hours for the demand balancing of polish power system in 2012 were analysed, the volume assessment of the DSR resources able in such hours to lower the high prices for balancing energy was evaluated and the concept of tariff containing the critical peak rate to control the DSM resources connected on low voltage level was presented.
PL
Tworzenie zasobów po stronie popytu zdolnych do uczestnictwa w bilansowaniu szczytowego zapotrzebowania w KSE staje się konieczne ze względu na przewidywany brak wystarczalności generacji. Przeanalizowano najtrudniejsze momenty w bilansowaniu polskiego systemu w roku 2012, dokonano oceny ilościowej zasobów DSR dla obniżenia wysokich cen energii bilansującej w godzinach krytycznych i przedstawiono koncepcję taryfy z krytyczną stawką cenową dla sterowania tymi zasobami przyłączonymi na poziomie niskiego napięcia.
PL
Omówiono jakość wyników uzyskiwanych przy wykorzystaniu uproszczonej metody wyznaczania szczytowych obciążeń stacji transformatorowych SN/nN.
EN
The paper discusses the quality of results obtained using simplified method, of determination of peak load of MV/LV transformer stations.
7
Content available remote Koncepcja rozwoju sieci terenowej średniego napięcia
PL
W artykule przedstawia się metodę wyznaczania obciążeń szczytowych stacji transformatorowych SN/nn pracujących w sieciach terenowych. Metoda ta będzie miała zastosowanie do badania rozwoju sieci terenowej SN. Omawia się koncepcję wyznaczania strategii rozwoju sieci SN metodą programowania dynamicznego. Jako funkcję kryterium przyjmuje się sumę zdyskontowanych kosztów rocznych w okresie T=5 lat.
EN
The method of determining peak loads of MV/LV transformer substations operating in terrain networks have been presented in the paper. The method will be used for investigation of MV terrain network development. Conception of determining the development strategy of MV networks by dynamic programming method has been discussed. The sum of discounted annual costs in the period of T = 5 years has been chosen as the criterion function.
PL
W pracy przedstawiono modele przydatne do wyznaczania rocznego obciążenia szczytowego wiejskiej stacji transformatorowej 15/0,4 kV, w postaci regresyjnych zależności pomiędzy obciążeniem szczytowym stacji, a zużyciem energii elektrycznej przez odbiorców zasilanych za jej pośrednictwem. Praca zawiera także analizę dobowej, tygodniowej i rocznej zmienności obciążeń odbiorców wiejskich oraz wyniki obliczeń rocznego czasu użytkowania mocy szczytowej, dokonanych w oparciu o wyniki ciągłej rejestracji poboru mocy czynnej w wybranych wiejskich stacjach transformatorowych.
EN
Paper presents the models useful to determination of annual peak load of a 15/0.4 kV rural transformer station, in form of regression dependences between the station peak load and consumption of electrical energy by the customers being supplied with energy through that station. Paper includes also an analysis of daily, weekly and annual variations in rural consumers' loads, as well as the calculations of yearly peak power use duration, based on the results of continuous recording of active power consumption in selected rural transformer stations.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.