Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  passive-carbon layer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Purpose: The aim of the work was determination of influence of the selected methods and parameters of bone union electrostimulation on corrosion of stainless steel implants coated with passive and passive-carbon layer. Design/methodology/approach: The semi-invasive and capacitively coupled electrical field methods of electrostimulation (without constant component) in rabbits were applied. The influence of electrostimulation on corrosion of implants was evaluated on the basis of the mass measurements and surface observations. Findings: On the basis of the research no corrosion on the implants stabilizing the bone fracture was observed. Research limitations/implications: Lack of visible and measurable corrosion requires the change of the methodology. Further research should be focused on the amount of metallic ions dissolved from the implants. Furthermore, it should be emphasized that the absence of corrosion of the electrostimulated implants is only one of many criteria describing the usefulness of electrostimulation parameters. The basic criterion is the biological effect obtained as the result of the electrostimulation. Practical implications: The obtained results are the basis for selection of methods and current parameters of the bone union electrostimulation in further clinical research. In case of positive results, the bone union electrostimulation with the use of implants coated with the passive and passive-carbon layers would be valuable method in treatment of pathological bone fractures. Originality/value: The paper is a continuation of the research on determining safe parameters of bone union electrostimulation of implants coated with the passive and passive-carbon layers.
PL
W pracy zbadano przydatność warstwy pasywno-węglowej wytworzonej na powierzchni stentów wieńcowych ze stali Cr-Ni-Mo dla potrzeb kardiologii zabiegowej. W szczególności przeprowadzono badania odporności na korozję wżerową w sposób uwzględniający technikę implantacji. Przydatność warstwy oceniano również w warunkach zmiennych cykli obciążeń. Dla potrzeb pracy wykonano stanowisko do badań zmęczeniowych stentów stymulujące pracę serca. Badania zmęczeniowe prowadzono przez okres 3 miesięcy w środowisku płynu fizjologicznego Tyrode'a z częstotliwością 180 cykli na minutę. Po zakończeniu badań implanty poddano również ocenie odporności korozyjnej. Ponadto zbadano topografię warstwy węglowej stosując metodę mikroskopii sił atomowych. Uzyskane w pracy wyniki wskazują na przydatność wytworzonej warstwy pasywno-węglowej do uszlachetniania powierzchni stentów wieńcowych.
EN
In the work the usefulness of passive-carbon layer deposited on surface of coronary stents made from Cr-Ni-Mo steel has been investigated. Particularly, investigations of pitting corrosion resistance in conditions which are taking into consideration the technique of stents implantation have been carried out. Usefulness of the layer has also been evaluated in conditions of changing of cyclic loading. Special device for fatigue tests of the stents was made for better simulation of heart's work. Fatigue tests were carried out by 3 months in Tyrode's physiologic solution with frequency of 180 cycles per minute. After finishing that investigations for corrosion resistance tests of the implants have been additionally performed. Moreover, the topography of carbon layer by the use of atomic force microscopy method has been investigated. The obtained results have pointed out on the usefulness of passive-carbon layer for quality improvement of coronary stents surface.
3
Content available remote Biomateriały metaliczne z warstwami pasywno-węglowymi dla kardiologii zabiegowej
PL
W pracy przedstawiono zakres badań, który zdaniem autorów pozwoli na kompleksową ocenę przydatności klinicznej zaproponowanej postaci użytkowej stentu wieńcowego z naniesioną warstwą pasywno-diamentową. Badania obejmują etap optymalizacji cech geometrycznych stentu wieńcowego i własności mechanicznych biomateriału metalicznego, badania odporności korozyjnej w warunkach symulujących środowisko tkankowe oraz badania w tkankach zwierząt doświadczalnych. Autorzy prognozują, że uzyskane już doświadczenia badawcze, interdyscyplinarne umożliwią opracowanie nowej postaci użytkowej stentu wieńcowego.
EN
The paper presents the program of the investigations that will be carried out to develop a new design of the coronary stent with the passive-carbon layer applied. Basing on the clinical experiennces gathered so far, the working properties of stents will be identified (geometrical properties, optimum metallic biomaterial, as well as the physical and chemical properties of their surface). Physical models of stents will be developed and the stress and strain state will be determined for the stationary boundary conditions that will make it possible to select the mechanical prperties of the metallic materials. Stent manufacturing technology will be developed and technology of refining their surface to improve their corrosion resistance, and therefore, to improve their biotolerance in contact with blood and artery wells. For refining the stent surfaces, techniques will be used that were developed by the authors within the framework of their research projects on implants for the osteous surgery (electrolytic polishing, chemical passivation, coating with the passive-carbon layers). Manufactured stents will be tested "in vitro" in the simulated laboratory conditions and subjected to verification in the tissues of the laboratory animals. To evaluate their quality, methods will be used that make it possible to determine the biochemical characteristics of stents, resistance of the metallic biomaterials to corrosion (pitting, crevice, and fatigue corrosion) and of their bio-tolerance (angiography, histopathological, and morphometric tests, as well as their hemocompatibility).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.