Aim: The aim of the article is to verify the fire resistance of aluminum-glass construction partitions with a parallel structure. The paper presents the results of tests in a fire chamber of a selected partition, a leading national manufacturer of aluminum-glass systems. The results of the fire tests were used to validate a simple parallel model of the reliability of non-renewable systems. Introduction: Fire-retardant properties of partitions made of glass and aluminum profiles determine their ability to stop the spread of fire by closing the fire in separate zones. Fire resistance of such partitions is measured according to various criteria, in particular the requirements concern: stability R (glass does not break), tightness E, radiation limitation W and insulation I. The tightness requirement E means that the partition effectively protects the fire compartment against flames, smoke and hot gases. The insulating postulate I means that the average temperature of glass and the profiles on the surface of the partition on the protected side does not exceed the contractual value during the nominal duration of the fire. The measure of fire resistance of a partition is time t, expressed in minutes, in which the structure of an aluminum-glass partition meets one or more of the criteria listed. Methodology: The experimental database consists of the results of routine fire resistance tests of system building partitions obtained in the certification process of selected facade systems. Interpretation of the obtained results of laboratory tests was based on simple models of reliability of non-renewable systems. Conclusions: The graphs of average temperature increase on the outer surface of the tested glass are the same in each case in terms of quality and quantity. Up to about 70% of the nominal fire resistance, the temperature increase is linear, followed by a non-linear phase according to a concave curve. The course of the temperature-rise curves on the outer surface of aluminum profiles is qualitatively different. The graphs are non-linear, convex from the beginning of heating, with the inflection point reached after about 20 minutes of the test. The obtained results may indicate that the multi-chamber structure of aluminum profiles does not ensure a parallel reliability structure, because the object has a quasi-parallel structure. The presented results of the temperature-rise curves and their reliability interpretation require confirmation in further laboratory tests of aluminum-glass partitions with a different structure of panes and profiles.
PL
Cel: Celem artykułu jest weryfikacja eksperymentalna odporności ogniowej przegród budowlanych aluminiowo-szklanych o strukturze równoległej. W pracy przedstawiono wyniki badań w komorze ogniowej na przykładzie przegrody wiodącego krajowego producenta systemów aluminiowo-szklanych. Wyniki testów ogniowych wykorzystano do walidacji prostego modelu równoległego niezawodności systemów nieodnawialnych. Wprowadzenie: Właściwości ognioochronne wykonanych ze szkła i profili aluminiowych przegród budowlanych określają ich zdolność do zatrzymania rozprzestrzeniania się ognia poprzez zamknięcie pożaru w wydzielonych strefach. Odporność ogniowa takich przegród jest mierzona wg różnych kryteriów. W szczególności wymagania dotyczą: stabilności R (szkło nie pęka), szczelności E, ograniczenia promieniowania W i izolacyjności I. Postulat szczelności E oznacza, że przegroda skutecznie chroni strefę wydzielenia pożarowego przed płomieniami, dymem i gorącymi gazami. Z kolei postulat izolacyjności I świadczy o tym, że średnia temperatura szyb i profili na powierzchni przegrody po stronie chronionej nie przekracza umownej wartości w nominalnym czasie trwania pożaru. Miarą odporności ogniowej przegrody jest czas t wyrażony w minutach, w którym konstrukcja przegrody aluminiowo-szklanej spełnia jedno lub kilka z wymienionych kryteriów. Metodologia: Bazę danych doświadczalnych stanowią wyniki rutynowych badań odporności ogniowej systemowych przegród budowlanych otrzymane w procesie certyfikacji wybranych systemów fasadowych. Interpretację wyników badań laboratoryjnych oparto na prostych modelach niezawodności systemów nieodnawialnych. Wnioski: Wykresy przyrostu temperatury średniej na zewnętrznej powierzchni badanych szyb są w każdym wypadku jakościowo i ilościowo takie same. Do momentu osiągnięcia około 70% nominalnej ogniochronności przyrost temperatury jest liniowy, po czym następuje faza nieliniowa wg krzywej wklęsłej. Jakościowo inny jest przebieg krzywych przyrostu temperatury na zewnętrznej powierzchni profili aluminiowych. Wykresy są od początku nagrzewania nieliniowe, wypukłe, z punktem przegięcia osiągniętym już po około 20 minutach testu. Otrzymane rezultaty mogą wskazywać, że wielokomorowość profili aluminiowych nie zapewnia struktury niezawodnościowej równoległej, ponieważ obiekt ma strukturę quasi-równoległą. Przedstawione wyniki krzywych przyrostu temperatury i ich interpretacja niezawodnościowa wymagają potwierdzenia w dalszych badaniach laboratoryjnych przegród aluminiowo-szklanych o innej konstrukcji szyb i profili.
PL
Przedmiotem artykułu są wybrane wymagania i właściwości charakteryzujące konstrukcje przegród z ogrzewaniem podłogowym. Autor analizuje wymagania odnoszące się do ochrony cieplnej podłóg oraz izolacyjność cieplną podłóg ogrzewanych. Podaje także charakterystykę podłóg pod względem odczuć komfortu cieplnego.
EN
The subject of this article is selected requirements and properties characterizing the construction of partitions with underfloor heating. The author analyzes the requirements for thermal protection of floors and thermal insulation of heated floors. It also gives the characteristics of the floors in terms of the feeling of thermal comfort.
3
Content available remote Projektowanie cieplne przegród stykających się z gruntem
PL
Artykuł stanowi kontynuację cyklu pt. „Fizyka cieplna budowli w projektowaniu, wznoszeniu i eksploatacji budynków”, w którym prezentowane są zagadnienia praktyczne współczesnego budownictwa. Tym razem przedstawiono zasady dotyczące projektowania przegród stykających się z gruntem. Opisano również metodologię obliczania strat ciepła wg polskich norm i rozporządzenia w sprawie warunków technicznych.
EN
The article is a continuation of the cycle entitled “Thermal physics of buildings in the design, construction and operation of buildings”, in which practical issues of modern construction are presented. This time, the principles of designing partitions in contact with the ground were presented. The methodology of calculating heat losses according to Polish standards and the ordinance on technical requirements was also described.
PL
Przedmiotem artykułu jest jakość cieplna przegród i złączy budowlanych budynków z uwzględnieniem wymagań obowiązujących od 1 stycznia 2021 r. Autor przytacza przepisy prawne w zakresie jakości cieplnej elementów obudowy budynków, a następnie omawia jakość cieplną poszczególnych elementów budynku, takich jak: ściany zewnętrzne, przegrody stykające się z gruntem, dachy i stropodachy, przegrody przezroczyste oraz złącza budowlane.
EN
The subject of the article is the thermal quality of building partitions and joints in buildings, taking into account the requirements in force since January 1, 2021. The author cites legal provisions regarding the thermal quality of building envelope elements, and then discusses the thermal quality of individual building elements, such as: external walls, partitions in contact with the ground, roofs and flat roofs, transparent partitions and construction joints.
EN
In the paper we investigate an algorithmic associative binary operation * on the set ℒℛ1 of Littlewood-Richardson tableaux with entries equal to one. We extend * to an algorithmic nonassociative binary operation on the set ℒℛ1 × ℕ and show that it is equivalent to the operation of taking the generic extensions of objects in the category of homomorphisms from semisimple nilpotent linear operators to nilpotent linear operators. Thus we get a combinatorial algorithm computing generic extensions in this category.
6
Content available remote Graphical Partitions and Graphical Relations
EN
We generalize the well-known correspondence between partitions and equivalence relations on a set to the case of graphs and hypergraphs. This is motivated by the role that partitions and equivalence relations play in Rough Set Theory and the results provide some of the foundations needed to develop a theory of rough graphs. We use one notion of a partition of a hypergraph, which we call a graphical partition, and we show how these structures correspond to relations on a hypergraph having additional properties. In the case of a hypergraph with only nodes and no edges these properties are exactly the usual reflexivity, symmetry and transitivity properties required for equivalence relations on a set. We present definitions for upper and lower approximations of a subgraph with respect to a graphical partition. These generalize the well-known approximations in Rough Set Theory. We establish fundamental properties of our generalized approximations and provide examples of these constructions on some graphs.
7
Content available remote On some partition functions related to some mock theta function
EN
We show that some partitions related to two of Ramanujan's mock theta functions are related to indefinite quadratic forms and real quadratic fields. In particular, we examine a third order mock theta function and a fifth order mock theta function.
PL
Pomieszczenia inwentarskie są niszami ekologicznymi wytwarzającymi specyficzny mikroklimat stwarzający warunki do zasiedlenia, życia i proliferacji różnorodnych mikroorganizmów. Drobnoustroje powodują rozkład i korozję materiałów budowlanych, ale przede wszystkim stwarzają zagrożenie zdrowotno-toksykologiczne. Problem wydaje się szczególnie istotny w niektórych systemowych technologiach wznoszenia budynków dla zwierząt. Ocenę stanu mikrobiologicznego przeprowadzono na ścianach bezściołowej tuczarni trzody chlewnej, wykonanych z elementów drewnopochodnych i wykończonych od wewnątrz twardymi płytami pilśniowymi. Materiał badawczy z przegród uzyskano wykorzystując metodę wymazów, które pobrano w dwóch seriach. Analiza mykologiczna pozwoliła stwierdzić obecność grzybów pleśniowych i drożdżopodobnych. Ponadto wymazy ze ścian wykazały obecność bakterii z rodzajów Saphylococcus, Streptococcus, Bacillus oraz pałeczek z grupy coli.
EN
Farm buildings are ecological niches producing specific microclimate, where various microorganisms can populate, live and proliferate. Microorganisms cause decay and corrosion of construction materials, but most of all they pose health and toxicological threat. The problem seems to be particularly important in certain system technologies of erecting buildings for animals. The microbiological condition evaluation was done on the walls of bedding-free pig fattening house, made of wood-like elements and finished from the inside with hardboard. The tested material from the partitions was obtained by using smear tests done in two series. Mycological analysis allowed for detecting the presence of mould and yeast-like fungi. Moreover, smear tests from the walls detected the presence of Saphylococcus, Streptococcus, Bacillus and coliform bacteria.
PL
Szklarnie są lekkimi budynkami z przegrodami o znacznym wpływie warunków klimatu zewnętrznego na zużycie energii cieplnej i mikroklimat. W referacie przedstawiono wyniki badań przeprowadzonych w trzech obiektach rzeczywistych z różnymi sposobami kształtowania budynków szklarniowych w aspekcie oszczędności energii. Pomiary wykonano dla szklarni wielonawowej i dwóch szklarni wolnostojących z różnymi typami ekranów termoizolacyjnych oraz uzupełniono o pomiar dla całego kompleksu szklarniowego. Zastosowanie ruchomych ekranów zmienia charakterystykę termiczną prze-gród zewnętrznych. Ekrany termoizolacyjne niwelują wpływ zmian temperatury zewnętrznej na wahania temperatury wewnątrz szklarni. Przebiegi zmian zużycia energii cieplnej w badanych szklarniach zblokowanej i wolnostojącej są istotnie różne. Wyniki tych badań prezentują zmienność zużycia energii cieplnej zależną od właściwości termicznych przegród zewnętrznych i warunków klimatu zewnętrznego.
EN
Hothouses are lightweight structures with partitions, with significant influence of the external climate on heat energy consumption and microclimate. The paper presents the results of research conducted in three real facilities with various methods of shaping hothouse facilities as regards energy saving. The measurements were performed for one multiaisle hothouse and one detached hothouse with various types of thermal insulation screens; the measurements were supplemented by the measurement for the whole hothouse complex. Using movable screens changes the thermal characteristics of external partitions. Thermal insulation screens level off the influence of the external temperature changes on the fluctuations of temperature inside the hothouse. The courses of heat energy consumption in the tested hothouses: grouped and detached are sig-nificantly different. The results of this research presents variability of heat energy consumption depending upon the thermal properties of the internal partitions and the external climate conditions.
10
Content available Probes for fault localization in computer networks
EN
Fault localization is a process of isolating faults responsible for the observable malfunctioning of the managed system. This paper reviews some existing approaches of this process and improves one of described techniques - the probing. Probes are test transactions that can be actively selected and sent through the network. Suggested innovations include: mixed (passive and active) probing, partitioning used for probe selection, logical detection of probing results, and adaptive, sequential probing.
first rewind previous Strona / 1 next fast forward last