Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 52

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  partition
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
PL
W artykule przedstawiono zasady określania parametrów fizykalnych i oceny złączy budowlanych oraz wpływu mostków cieplnych w całkowitych stratach ciepła.
EN
The article presents the principles of determining physical parameters and assessing building joints, as well as the impact of thermal bridges on total heat losses.
2
Content available On the path partition of graphs
EN
Let G be a graph of order n. The maximum and minimum degree of G are denoted by Δ and δ, respectively. The path partition number μ(G) of a graph G is the minimum number of paths needed to partition the vertices of G. Magnant, Wang and Yuan conjectured that [formula]. In this work, we give a positive answer to this conjecture, for Δ ≥ 2δ.
3
Content available remote Całkowite przenikanie ciepła przez elementy obudowy budynku
PL
W artykule przedstawiono procedury obliczeniowe wraz z przykładem obliczeniowym w zakresie określania strat ciepła przez przenikanie przez elementy obudowy budynku.
EN
The article presents calculation procedures together with a calculation example in the field of determining heat loss by penetration through elements of the building envelope.
4
Content available remote Budownictwo modułowe w kontekście wymagań akustycznych
PL
Artykuł omawia zagadnienia dotyczące akustyki w budownictwie modułowym. Na przykładzie budynku wykonanego w technologii modułowej pokazano, że taki budynek może charakteryzować się bardzo dobrymi parametrami akustycznymi, porównywalnymi, a nawet lepszymi od tradycyjnego budynku murowanego lub żelbetowego, i może spełniać wszystkie obowiązujące prawnie wymagania akustyczne.
EN
The article discusses acoustics in modular construction. The example of a building made in modular technology shows that such a building can have very good acoustic parameters, comparable or even better than a traditional brick or reinforced concrete building, and can meet all legally applicable acoustic requirements.
EN
With the rapid development of urban area of Xi’an in recent years, the contradiction between ecological environmental protection and urban development has become prominent. The traditional remote sensing classification method has been unable to meet the accuracy requirements of urban vegetation monitoring. Therefore, how to quickly and accurately conduct dynamic monitoring of urban vegetation based on the spectral component characteristics of vegetation is urgent. This study used the data of Landsat 5 TM and Landsat 8 OLI in 2011, 2014 and 2017 as main information source and LSMM, region of variation grid analysis and other methods to analyse the law of spatial-temporal change of vegetation components in Xi’an urban area and its influencing factors. The result shows that: (1) The average vegetation coverage of the study area from 2011 to 2017 reached more than 50 %, meeting the standard of National Garden City (great than 40 %). The overall vegetation coverage grade was high, but it had a decreasing trend during this period. (2) The vegetation in urban area of Xi’an experienced a significant change. From 2011 to 2017, only 30 % of the low-covered vegetation, 24.39 % of the medium-covered vegetation and 20.15 % of the high-covered vegetation remained unchanged, while the vegetation in the northwest, northeast, southwest and southeast of the edge of the city’s third ring changed significantly. (3) The vegetation quality in urban area of Xi’an has decreased from 2011 to 2014 with 6.9 % of vegetation coverage reduced; while from 2014 to 2017, the overall vegetation quality of this area has improved with 2.1 % of the vegetation coverage increased, which was mainly attributed to urban construction and Urban Green Projects. This study not only can obtain the dynamic change information of urban vegetation quickly, but also can provide suggestions and data support for urban planning of ecological environmental protection.
6
Content available Improving LUT count of FPGA-based sequential blocks
EN
Very often, a digital system includes sequential blocks which can be represented using a model of the finite state machine (FSM). It is very important to improve such FSM characteristics as the number of used logic elements, operating frequency and consumed energy. The paper proposes a novel technology-dependant design method targeting LUT-based Mealy FSMs. It belongs to the group of structural decomposition methods. The method is based on encoding the product terms of Boolean functions representing the FSM circuit. To diminish the number of LUTs, a partition of the set of internal states is constructed. It leads to three-level logic circuits of Mealy FSMs. Each function from the first level requires only a single LUT to be implemented. The method of constructing the partition with the minimum amount of classes is proposed. There is given an example of FSM synthesis with the proposed method. The experiments with standard benchmarks were conducted. They show that the proposed method can improve such FSM characteristics as the number of used LUTs. This improvement is accompanied by a decrease in performance. A positive side effect of the proposed method is a reduction in power consumption compared with FSMs obtained with other design methods.
PL
Przedstawiono historię ruchu stowarzyszeniowego polskich elektrotechników w czasie zaborów. Opisano rozwój elektrotechnicznych zrzeszeń w sześciu miastach, w których zdołały się ukonstytuować do odzyskania niepodległości, w ramach stowarzyszeń ogólnotechnicznych. Podkreślono udział poszczególnych elektrotechników w działalności tych zrzeszeń, omówiono także tematykę elektrotechniczną na Zjazdach Techników Polskich.
EN
The history of the association movement of Polish electrotechnics during the partitions was presented. The development of electrotechnical associations in six cities was described, in which they managed to establish the independent electrotechnics associations within the framework of general engineering associations. The participation of individual electrotechnics in the activities of these associations was emphasized, and the electrotechnics at the Congresses of Polish Technicians were also discussed.
PL
Artykuł dotyczy wpływu niepewności pomiaru gęstości betonu o dwóch wskaźnikach wodno-cementowych na izolacyjność akustyczną przegrody betonowej. Wyznaczono rozkłady gęstości betonów dla wskaźników w/c = 0,5 oraz 0,4. Następnie, stosując wzór określający zależność izolacyjności akustycznej od masy powierzchniowej oraz twierdzenie o funkcji zmiennej losowej, wyznaczono parametry rozkładu izolacyjności akustycznej ściany betonowej o grubości 18 cm. Porównano wpływ wskaźnika wodno-cementowego betonu na odchylenie standardowe izolacyjności akustycznej.
EN
The article discusses the influence of concrete density uncertainty – based on two water-cement indicators – on the acoustic insulation of the concrete partition. Concrete density distributions were determined for the ratios w/c = 0.5 and 0.4. The parameters of concrete density normal distribution were determined by means of Pearson test. Then, using the formula determining the dependence of acoustic insulation on the area mass and the theorem of the random variable function, the parameters of the acoustic insulation distribution for the 18 cm thick concrete wall were determined. The influence of the water-cement indicator on the standard deviation of the acoustic insulation was compared.
PL
W artykule przedstawiono wyniki badań próbek z betonu komórkowego o klasie gęstości 500 kg/m3. Próbki poddano intensywnemu działaniu wody, a następnie suszono w warunkach laboratoryjnych, tj. w temperaturze ok. 20°C i wilgotności względnej ok. 30%. Proces suszenia trwał sześć miesięcy. W kolejnych miesiącach trwania procesu przedstawiano zmienne profile zawartości wilgoci. Proces suszenia dostarcza informacji o materiale w szerokim zakresie wilgotności względnych – od zakresu higroskopijnego do zakresu nasyconego. Jednakże nie ma norm dotyczących badania tego procesu. Nie ma określonego parametru materiałowego, który należałoby wyznaczać. W literaturze można jedynie znaleźć propozycje określania parametrów suszenia.
EN
The article presents the results of an experiment which were conducted on the samples of aerated concrete of density class 500 kg/m3. The samples were previously exposed to excess moisture and then dried in laboratory conditions i.e. at the temperature of approximately 20°C and at the relative humidity of approximately 30%. The drying process has lasted six months. In the following months of the experiment the variable profiles of moisture content through partition thickness were recreated. The drying experiment provides information about the material in a wide range of relative humidity – from the hygroscopic to the supersaturated range. However, there are no standards for testing this process. There is no specific material parameter that should be determined. Only proposals for determining drying parameters are given in the literature.
PL
W pracy przedstawiono analizę możliwości wykorzystania betonów lekkich zawierających odpadowe kruszywa lekkie do wykonania elementów konstrukcyjnych budynku (stropu) oraz ich wybrane właściwości fizyczne i mechaniczne. Przedstawiono wyniki obliczeń obciążenia stropów oraz współczynnika przenikania ciepła przegród budowlanych wykonanych z omawianych w pracy betonów lekkich. Na podstawie przeprowadzonych obliczeń oceniono wpływ poszczególnych parametrów na wytrzymałość i izolacyjność cieplną ścian i stropów. Beton wykonany na kruszywie pollytag miał najniższą gęstość oraz współczynnik przewodzenia ciepła.
EN
The work presents the possibility of using lightweight concrete made of waste lightweight aggregates for constructions elements (floor loading ) as well as their physical and mechanical properties. It includes results of calculations concerning floor loading and heat transfer coefficient of building elements made of the presented lightweight concretes. Calculations provided the basis for assessing the impact of particular parameters on compressive strength and thermal insulation of walls and floors. The paper additionally describes concretes made of waste aggregates in the form of lytag (Pollytag) and slag. Based on the research, it was found that concrete containing Pollytag had the lowest density value and thermal conductivity coefficient.
PL
Drgania mechaniczne stropów w budynkach przeznaczonych na stały pobyt ludzi (np. biura, mieszkania) jak i poziom hałasu panujący w pomieszczeniu mają znaczący wpływ na subiektywne odczucie komfortu osoby eksponowanej na te zjawiska. W polskich przepisach dopuszczalne wartości dla prędkości zarówno drgań, jak i poziomu ciśnienia akustycznego A-ważonego są podawane przez osobne dokumenty i stanowią osobny przedmiot oceny. Niniejszy artykuł stanowi analizę, przy użyciu metod uproszczonych, sprzężenia mechano-akustycznego, jakim jest generowanie hałasu w pomieszczeniu przez drgające przegrody ograniczające to pomieszczenie z wykorzystaniem wartości progowych odczuwania drgań.
16
Content available Hubtic number in graphs
EN
he maximum order of partition of the vertex set V(G) into hub sets is called hubtic number of G and denoted by [formula]. In this paper we determine the hubtic number of some standard graphs. Also we obtain bounds for [formula]. And we characterize the class of all (p, q) graphs for which[formula].
17
Content available Hardware reduction for LUT-based mealy FSMs
EN
A method is proposed targeting a decrease in the number of LUTs in circuits of FPGA-based Mealy FSMs. The method improves hardware consumption for Mealy FSMs with the encoding of collections of output variables. The approach is based on constructing a partition for the set of internal states. Each state has two codes. It diminishes the number of arguments in input memory functions. An example of synthesis is given, along with results of investigations. The method targets rather complex FSMs, having more than 15 states.
18
Content available remote Ocena głębokości zwęglenia elementów drewnianych w ustrojach powierzchniowych
PL
Problem obliczeniowego wyznaczania nośności drewnianych elementów powierzchniowych w warunkach pożaru jest ważnym zagadnieniem bezpieczeństwa pożarowego. Specyficzne interakcje elementów nośnych konstrukcji z ich okładzinami i wypełnieniem (lub jego brakiem) powodują, że ocena i modelowanie przebiegu utraty nośności w czasie pożaru takich konstrukcji sprawia istotne trudności. Otoczenie elementów nośnych ma szczególnie duży wpływ na zwiększenie warstwy zwęglonej elementów nośnych, a co za tym idzie tempa utraty ich nośności. W artykule przedstawiono dwa podejścia do tego zagadnienia stosowane w Europie i na świecie: uwzględniające Eurokody oraz dokument Fire safety in timber buildings – Technical guideline for Europe. Przedstawiono podstawy teoretyczne, zakresy stosowania i ograniczenia w przypadku tych podejść. Jako przykład praktyczny zaprezentowano porównanie wyników procedur obliczeniowych z badaniem przeprowadzonym w Laboratorium Badań Ogniowych ITB w Pionkach.
EN
The problem of establishing load bearing capacity of wooden surface elements in the case of fire is an important problem of fire safety. Particular interactions between load bearing members and their claddings and insulations (or the lack thereof) render modelling and assessment of load bearing failure in the case of a fire a troublesome task. In particular, surroundings of the load bearing members have important influence on the charring layer development, and what follows - on the rate of load bearing capacity loss. In the paper two approaches to this problem utilised in Europe and in the World are presented: one included in current Eurocodes, and one from a document Fire safety in timber buildings – Technical guideline for Europe. Theoretical basis, range of applicability and shortcomings of these approaches are presented. As a practical example a comparison of results from tests conducted in Pionki Fire Research Laboratory with results of calculation procedures are presented.
19
Content available remote Buforowanie wilgoci przez innowacyjne przegrody wewnętrzne
PL
W artykule przedstawiono wyniki z badań dotyczących tzw. buforowania wilgoci MBV (z ang. Moisture Buffer Value) przez przegrody, w których zastosowano higroskopijne biomateriały, powstałe na bazie surowców odnawialnych. Wszystkie z przebadanych konstrukcji ściennych, przy zmiennym obciążeniu wilgocią (50 – 80%), wykazały się „dobrą” klasą buforowania wilgoci w odniesieniu do skali zaproponowanej przez Rode [11]. Przedstawione wyniki potwierdzają, że na potencjał buforowania wilgoci przez poszczególne przegrody wpływ mają zastosowane w nich materiały, w szczególności skład surowcowy.
EN
In this paper, the results of Moisture Buffering Test (MBV) of the internal walls with a range of different internal and external layers, made from renewable, hygroscopic row-materials were presented. All of the investigated wall assemblies, with varying moisture loads in the range (50 – 80%), showed “good” moisture buffering value in relation to the buffer class proposed by Rode [11]. The presented results confirmed that the moisture buffer potential of the assemblies is influenced by used materials especially theirs material composition and structure.
PL
W artykule przedstawiono szczegóły nowelizacji PN-B-02151-3 w zakresie wymaganej izolacyjności akustycznej od dźwięków powietrznych i uderzeniowych przegród wewnętrznych budynków mieszkalnych oraz użyteczności publicznej. Omówiono wady i zalety nowego sposobu określenia wymagań zastosowanego w nowelizacji normy. Wyszczególniono także merytoryczne podstawy zakresu nowelizacji.
EN
The article presents the details of the amendment to the PN-B-02151-3 in the scope of the required of airborne and impact sound insulation of internal partitions of residential and public buildings. It is discussed the pros and cons of a new method of determining the requirements used in the amendment of the standard. It details the substantive grounds for the scope of the amendment are presented.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.