Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pH sensor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Optical pH detector based on LTCC and sol-gel technologies
EN
Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okolna 2, 50-422 Wrocław, Poland This paper presents an investigation on using sol-gel thin film as a material for sensors application in LTCC (Low Temperature Co-fired Ceramics) technology. This material gives the opportunity to make new, low-cost highly integrated optoelectronic devices. Sensors with optical detection are a significant part of these applications. They can be used for quick and safe diagnostics of some parameters. Authors present a pH detector with the optical detection system made of the LTCC material. The main part of the device is a flow channel with the chamber and sol-gel active material. The silica sol-gel with bromocresol green indicator was used. As the absorbance of sol-gel layer changes with the pH value of a measured medium, the transmitted light power was measured. The pH detector was integrated with the electronic components on the LTCC substrate.
2
Content available remote Miniaturized textile-based multi-layer pH-sensor for wound monitoring applications
EN
Wound assessment has become an important issue in the wound treatment procedure. One important indicator of the wound status is the pH value. Our approach to assess this quantity is through use of a fiber sensor coated with a pH-responsive hydrogel, which functions as a sensitive layer for impedance measurements. An advantage of this is its integratability into wound dressings using standard textile technologies. The pH characteristic shows a pH-dependent behavior of the absolute impedance at certain frequencies. The fabrication technology and sensor characteristics are discussed. The values of almost 14% impedance change demonstrate the potential for improvement by optimizing fabrication technologies. The presented sensor meets all requirements necessary for wound pH assessment.
3
Content available remote Planar ruthenium oxide sensors for cell-on-a-chip metabolic studies
EN
While the use of indium oxide electrodes for neuronal stimulation and pH sensing is continuously increasing, ruthenium oxide is a material less familiar in biomedicine. However, ruthenium oxide deposited by reactive sputtering glass or ceramic substrate with a platinum contact layer is shown to yield sensors well suitable for a extracellular recording of cell-mediated pH changes in cell culture media. Ruthenium oxide was directly grown with MCF-7 and L 929 cells and is fully biocompatible. The pH sensitivity ranges between 52 and 58 mV/pH. it is approximately linear between pH 5.5 and pH 11. The drift typically ranges between I and 2 mV h-1 With increasing thickness of the ruthenium oxide layer, drift decreases and response time increases. A practicable tradeoff is a thickness of 1-2 um. A pronounced redox cross-sensitivity of ruthenium oxide is a limiting factor in situations where concentration of dissolved oxygen is not constant or cannot be determined independently. The observed sensitivity to dissolved oxygen is ≈ 0.2 mV/hPa. Ruthenium oxide spots on ceramic sensor chips were used for an exemplary cell based assay with MCF-7 cells and showed a response of extracellular acidification rate to the alkaloid drug cytocha-lasin B.
PL
Zastosowanie elektrod wykorzystujących tlenek irydu w neuronowej stymulacji i pomiarach pH wzrasta, lecz tlenek rutenu jest mniej powszechnie spotykany w biomedycynie. Niemniej, wykazano, że tlenek rutenu osadzony w wyniku napylania na szklanym lub ceramicznym substracie z kontaktem platynowym może tworzyć czujniki przydatne do pozakomórkowego rejestrowania regulowanych przez komórkę zmian pH w kulturach komórkowych. Tlenek rutenu jest w pełni kompatybilny z komórkami MCF-7 i L 929. Czułość pH waha się w granicach miedzy 52 a 58 mV/pH, i jest w przybliżeniu liniowa między pH 5,511. Dryft zwykle jest zawarty w granicach l do 2 mV h-1. Wzrost grubości warstwy tlenku rutenu powoduje zmniejszenie dryftu i przedłużenie czasu odpowiedzi. Optymalna grubość wartswy wynosi 1-2 urn. Interferencje redoks są istotnym czynnikiem ograniczającym stosowanie czujników gdy stężenie rozpuszczonego tlenu jest zmienne lub gdy nie może być niezależnie określone. Zaobserwowana czułość na rozpuszczony tlen wynosi ≈ 0,2 mV/hPa. Kropki tlenku rutenu w ceramicznych czujnikach były stosowane z komórkami MCF-7 i pozwaliły obserwować wpływ leku cytochalazyny B na szybkość pozakomórkowego zakwaszania.
4
Content available remote Different approaches of pH measurements
EN
This paper compares different approaches of pH measurements and concerned pH sensors. Apart of the conventional glass electrode there are described principles and the advantages of other type of pH sensors such an electrode based on polymeric membrane, a semiconductive ISFET and a fibre-optic pH sensor. The ability of sensor's miniaturization was discussed as one of the main factor in further applications.
PL
Artykuł porównuje różne sposoby pomiarów pH i odpowiednie czujniki pH. Obok konwencjonalnej, szklanej elektrody pH opisano zasady działania i zalety innych typów czujników pH, takich jak elektroda z polimerową membraną, półprzewodnikowy tranzystor polowy typu ISFET oraz światłowodowy czujnik pH. Jako jeden z głównych parametrów czujnika pH w dalszych zastosowaniach omówiono możliwości jego miniaturyzacji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.