Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  płyty płaskie
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Linear, nonlinear and test comparison analyses of flat plate slabs with shear reinforcement are presented in the article. Analyses of slabs with and without shear reinforcement by nonlinear simulations are introduced. The calculations of slabs without and with 0.16 m eccentricities were performed. For analyses finite element method were used. Design models of flat slab with column by “Lira SAPR” software were carried out. After the calculations whole results with experimental investigations were compared. The comparison analyses were shown, that presence of shear reinforcement far increase the capacity of slabs. Furthermore, the presence of shear reinforcement depends on eccentricity increases the axial force approximately 25%. Moreover, the difference between tests and nonlinear analyses results are about 6.4%.
PL
W artykule przedstawiono liniowe, nieliniowe i doświadczalne analizy porównawcze płaskich płyt stropowych ze zbrojeniem na ścinanie. Przeprowadzono analizy płyt ze wzmocnieniem i bez zbrojenia z wykorzystaniem symulacji nieliniowych. Wykonano obliczenia płyt bez mimośrodów i z mimośrodami 0,16 m. Do analiz wykorzystano metodę elementów skończonych. Wykonano modelowanie płaskiej płyty ze słupem za pomocą oprogramowania "Lira SAPR". Po zakończeniu obliczeń porównano wyniki z badaniami eksperymentalnymi. Analizy porównawcze wykazały, że obecność zbrojenia na ścinanie znacznie zwiększa zdolność płyt do przenoszenia obciążeń. Ponadto obecność zbrojenia na ścinanie zależy od mimośrodowości, a siła osiowa wynosi około 25%. Co więcej, różnica pomiędzy testami i wynikami analiz nieliniowych wynosi około 6,4%.
EN
The four storey in situ reinforced concrete frame-wall building by flat plate system is presented in the article, which under static and seismic loads was calculated. Only the middle column of the building in the paper was reviewed and all computations by LIRA were done. The calculations according to Armenian and Russian building codes were implemented and satisfied these conditions. The supremum and infimum bending moments and axial forces of column for flat plate analyses were determined and compared. At the same time there were carried out computations taking into account the punching shear action of slabs. The results are shown that the differences of axial forces between static and dynamic loads are negligible, however of the volume of punching shear is huge enough.
PL
W artykule przedstawiono istniejący budynek czterokondygnacyjny o żelbetowej konstrukcji szkieletowej słupowo-płytowej, do którego obliczeń przyjęto wpływ obciążeń statycznych oraz sejsmicznych. W opracowaniu omówiono słup środkowy, a analizy obliczeniowej dokonano za pomocą programu obliczeniowego LIRA. Analizę wykonano na podstawie norm armeńskich oraz rosyjskich, a otrzymane wyniki spełniają założenia obu norm. W celu przeprowadzenia analiz płyty płaskiej określono i porównywano obwiednie momentów zginających oraz sił osiowych słupa. Przeprowadzono również obliczenia mające na celu sprawdzenie nośności płyty na przebicie. W wyniku analizy stwierdzono, że różnice sił osiowych wyznaczonych przy uwzględnieniu obciążeń statycznych oraz dynamicznych są niewielkie, jednakże róż- nice wielkości nośności na przebicie są dość duże.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.