Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  płaskie kolektory słoneczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The subject of the work is an analysis of two types of solar collectors: flat-plate and evacuated tube collectors in the same, natural working conditions during the period from 1st May 2017 to 30th September 2017. The scope of work includes a descriptive presentation of a measuring setup, located on the roof of the building of the Construction University of Warmia and Mazury in Olsztyn, and also the research methodology, as well as an analysis of the results and conclusions obtained. The measurements allow a comparison of the efficiency of the flat-plate and evacuated tube collectors by calculating heat yields, based on the following variants: average hourly irradiation, outdoor air temperature, temperature of the medium supplying the collectors and temperature of the returning medium. An analysis of the heat yield was made in relations to the individual absorber surface, to determine which of the tested collectors showed higher efficiency under real operating conditions during the spring-summer period.
PL
W artykule przedstawiono algorytm obliczeń cieplnych związanych z konwersją promieniowania cieplnego oraz analizę efektów pracy instalacji solarnej przy użyciu metody korelacyjnej f-chart. Zaprezentowany algorytm obliczeń cieplnych oraz omówiona w artykule podstawowa odmiana metody f-chart zostały poparte przykładem obliczeniowym dla instalacji solarnej, która wykorzystana jest do wspomagania układu przygotowania c.w. dla potrzeb budynku jednorodzinnego, zlokalizowanego w trzeciej strefie klimatycznej Polski. W prowadzonych obliczeniach zakładano najbardziej niekorzystny wariant obliczeniowy, który wpływał na zwiększenie strat cieplnych kolektora. Obliczenia przeprowadzono dla normatywnego zużycia c.w. przy jej zapotrzebowaniu 75 l/dzień przez osobę i założeniu, że przyjęty do rozważań budynek zamieszkiwany jest przez rodzinę czteroosobową. Algorytm obliczeniowy przeprowadzono dla instalacji solarnej z płaskimi kolektorami cieczowymi, przy wyborze których kierowano się popularnością oraz jednoznacznie określoną powierzchnią czynną.
EN
In the paper presented is the algorithm for thermal calculation and the analysis of the effects of installation with solar collectors using f-chart methods. The presented algorithm and the basic version of the f-chart method, which in the article was presented too, were supported by sample calculation for the selected solar installation. This system is used to power control of hot domestic water for the needs of single-family building. The building which was adopted into consideration is located in the third climate zone in Poland. For the calculation the worst variant of conditions was assumed. It generates the most heat losses of the solar collector. Calculations were carried out for the standard water consumption equal 75 l/day per person and assumed that the building is inhabited by four people. Calculations were carried out for the installation with flat-plate collectors. Selection of such collectors was determined by their popularity and precisely defined surface.
PL
W artykule przedstawiono wyniki porównania efektywności cieplnej płaskich kolektorów słonecznych wyposażonych w absorbery wykonane z miedzi oraz aluminium. Zaprezentowano wyniki analizy CFD rozkładu temperatury na powierzchni miedzianych i aluminiowych absorberów i omówiono wpływ współczynnika przewodzenia ciepła absorbera na efektywność cieplną płaskich kolektorów słonecznych.
EN
Paper presents the comparison of thermal efficiency of solar collectors witch copper and aluminum absorbers. CFD results of temperature distribution on copper and aluminum absorber surface have been shown in order to explain the influence of thermal conductivity coefficient on solar collector efficiency.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.