Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  płaska płyta
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Nanofluids have found widespread practical applications in heat transfer, including cooling oils for diverse uses like automobile radiators, solar and nuclear power systems, biomedical devices, ventilation, heating, air conditioning, refrigeration, engine cooling, and transformers. Extensive scientific studies have investigated the impact of exotic fluids when combined with traditional heat transfer fluids, revealing that this combination enhances heat transfer performance beyond that of conventional working fluids. Collectively, these studies demonstrate the impressive heat transfer abilities of nanofluids. To optimize the efficiency of flat plate solar collectors, a comprehensive approach integrating theory and experimentation is essential. The results of such research highlight that increasing both the mass flow rate and concentration of nanofluids can lead to significant efficiency improvements, with potential enhancements ranging from 20% to 85%.
PL
Nanociecze znalazły szerokie praktyczne zastosowanie w wymianie ciepła. Oleje chłodzące w tym oleje stosowane są w różnych zastosowaniach, takich jak chłodnice samochodowe, systemy energii słonecznej i jądrowej, urządzenia biomedyczne, wentylacja, ogrzewanie, klimatyzacja, chłodnictwo, chłodzenie silników i transformatorów. Celem szeroko zakrojonych badań naukowych było zbadanie wpływu egzotycznych cieczy w połączeniu z tradycyjnymi cieczami przenoszącymi ciepło, ujawniając, że ta kombinacja poprawia wydajność wymiany ciepła w porównaniu z konwencjonalnymi cieczami roboczymi. Badania wykazały imponujące zdolności przenoszenia ciepła przez nanociecze. Optymalizacja wydajności płaskich kolektorów słonecznych polega na kompleksowym podejściu łączącym metody teoretyczne oraz badania eksperymentalne. Wyniki takich badań podkreślają, że zwiększenie zarówno masowego natężenia przepływu, jak i stężenia nanocieczy może prowadzić do potencjalnej poprawy wydajności w zakresie od 20% do 85%. Celem tego artykułu jest zaprezentowanie osiągnięć naukowych w zakresie implementacji nanocieczy do zwiększenia efektywności cieplnej płaskich kolektorów słonecznych.
EN
The paper experimentally and theoretically considers the issues of assessing the robustness and resistance to progressive collapse of a flat slab with a sudden removal of the central support. The results of testing two scale models of a fragment of a flat ceiling in the case of removal of the central support under static (specimen FS-1) and dynamic (specimen FS-2) loading are presented and analyzed. A theoretical approach to the quantitative assessment of robustness was tested, which is based on the provisions of the energy balance of a damaged structural system in an accidental design situation.
EN
The paper presents the results of punching shear values with reinforcement based on calculations of two and four storey cast–in–place reinforced concrete flat plate system buildings with spans of 4 and 7 m in accordance with Armenian, Russian, European and American building codes under seismic action. The effect of punching shear on both interior and edge columns was carried out. All calculations by LIRA, Design Expert and RCM ACI–builder softwares were implemented. In contrast to Eurocode 2 (EN 2) and American Concrete Institute (ACI), the building codes of the Republic of Armenia (SNiP) do not include the influence of bending moment in shear stress equation. To analyze the systems finite element method (FEM) was used. The results of comparison analyses shown that according to SNiP the shear stresses do not exceed the limit even without reinforcement, whereas by foreign standards the differences between peak shear stresses with reinforcement and permissible shear reinforcement are marginal. To conclude, in shear stress condition the internal bending moments have a significant role, especially in seismic regions.
PL
W artykule przedstawiono wyniki pomiarów wytrzymałości na ścinanie w oparciu o obliczenia dla dwu i czteropiętrowych budynków żelbetowych o rozpiętości 4 i 7 m, zgodnie z ormiańskimi, rosyjskimi, europejskimi i amerykańskimi normami budowlanymi, w strefie oddziaływań sejsmicznych. Przeprowadzono badania dotyczące przebicia zarówno dla słupów wewnętrznych, jak i narożnych. Wszystkie obliczenia wykonano w programach LIRA, Design Expert i RCM ACI–builder. W przeciwieństwie do Eurokodu 2 (EN 2) oraz American Concrete Institute (ACI) przepisy budowlane Republiki Armenii (SNiP) nie uwzględniają wpływu momentu zginającego na równanie dla naprężeń stycznych. Do analizy układów konstrukcyjnych wykorzystano metodę elementów skończonych (MES). Wyniki analiz porównawczych wykazały, że zgodnie z SNiP naprężenia ścinające nie przekraczają wartości granicznych nawet bez użycia zbrojenia, podczas gdy według norm obcojęzycznych różnice pomiędzy ekstremalnymi naprężeniami ścinającymi z użyciem zbrojenia a dopuszczalnym ścinaniem zbrojenia są marginalne. Podsumowując, dla warunków dotyczących naprężenia ścinającego wewnętrzne momenty zginające mają duże znaczenie, zwłaszcza na obszarach objętych oddziaływaniami sejsmicznymi.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.