Content available Systems of heat pumps in water
EN
The number of words in abstract should be placed in a range between 100 and 300 words. It should be justified, Times New Roman font 12 pt., spacing before 10 pt., spacing between lines 1pt. The text should be clear and complex and involve the base problems of a paper, information about methodology and results, a conclusion is crucial.
EN
HVAC systems use a substantial part of the whole energy usage of buildings. The optimizing of their operation can greatly affect the power use of a building, making them an interesting subject when trying to save energy. However, this should not affect the comfort of the people inside. Many approaches aim to optimize the operation of the heating and cooling system; in this paper, we present an approach to steer the heat pumps to reduce energy usage while aiming to maintain a certain level of comfort. For this purpose, we employ a market-based distributed method for power-balancing. To maintain the comfort level, the market-based distributed system assigns each device a cost-curve, parametrized with the current temperature of the room. This allows the cost to reflect the urgency of the HVAC operation. This approach was tested in a real-world environment: we use 10 heat pumps responsible for temperature control in 10 comparable-sized rooms. The test was performed for 3 months in summer. We limited the total peak power, and the algorithm balanced the consumption of the heat pumps with the available supply. The experiments showed that the system successfully managed to operate within the limit (lowering peak usage), and - to a certain point – reduce the cost without significantly deteriorating the working conditions of the occupants of the rooms. This test allowed us to estimate the minimal peak power requirement for the tested set-up that will still keep the room temperatures in or close to comfortable levels. The experiments show that a fully distributed market-based approach with parametrized cost functions can be used to limit peak usage while maintaining temperatures.
PL
W artykule opisano studium przypadku zastosowania systemu WLHP w budynku biurowo-usługowym o pow. 7500 m2 jako efektywnego energetycznie i ekologicznego systemu zapewniającego komfort cieplny przy niskich kosztach eksploatacyjnych. Opisano proces projektowy i zasady projektowania układów z pompami ciepła na reprezentatywnej kondygnacji budynku.
EN
The article describes a case study of the WLHP system in an office building with an area of 7500 m2 as an energy-efficient and ecological system ensuring thermal comfort and low operating costs. The design process and principles of designing systems with heat pumps on one of the representative floors of the building has been described.
PL
Chłodnictwo jest obecnie w bardzo trudnym momencie. W związku z globalnym ociepleniem klimatu wprowadza się kolejne ograniczenia w używaniu syntetycznych czynników chłodniczych. Ograniczenia te dotyczą nie tylko Polski, ale całej Unii Europejskiej. Jednym z problemów jest to, że czynniki o niskim GWP są często palne. W rezultacie nieopłacalna kiedyś pętla wodna staje się technologią w centrum zainteresowań. Dlaczego właśnie teraz? Jak to działa? Jakie są wady i zalety tego rozwiązania? Warto przeczytać w poniższym artykule.
PL
Przedstawiono analizę sposobu doboru pomp ciepła woda-powietrze w układzie pętli wodnej oraz różnych sposobów zagospodarowania zysków ciepła. Podstawą analizy jest bilans ciepła pomieszczeń i całego budynku.
EN
An analysis is presented concerning a selection method of hot water-air pumps operating in a water loop system. Various ways of utilisation of heat gains are included. The basis of the analysis is the heat balance for rooms and for the total building.