Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ozone concentration
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Research of the energy parameters of the vibro-ozonation complex
EN
In the system of technological operations of post-harvest processing of grain, the most important place belongs to drying. High-quality drying not only ensures the storage of the harvested crop, prevents its loss, but in some cases also improves the quality of the finished product. It is at this stage that up to 80% of all the energy of the post-harvest processing of grain is spent, and the useful use of energy in the grain dryers is up to 40…45%. The direction of improvement of grain drying technologies is: reduction of energy costs for moisture removal, ensuring environmental safety of the dried product, development of highly efficient grain drying equipment. A significant intensification of the grain drying process can be achieved by using the vibration effect on the processed material with simultaneous treatment with ozone as part of the drying agent, which additionally reduces the energy costs of the operation and allows obtaining a high-quality final material. The energy parameters of the developed vibro-ozonation complex, depending on the mode parameters of the studied process of drying grain raw materials, were experimentally investigated in the article.
PL
W systemie operacji technologicznych pozbiorczej obróbki ziarna najważniejsze miejsce zajmuje suszenie. Wysokiej jakości suszenie nie tylko zapewnia przechowywanie zebranego plonu, zapobiega jego utracie, ale w niektórych przypadkach poprawia również jakość gotowego produktu. To właśnie na tym etapie zużywa się do 80% całej energii na pozbiorczą obróbkę ziarna, a użyteczne wykorzystanie energii w suszarniach zbożowych sięga 40…45%. Kierunkiem doskonalenia technologii suszenia ziarna jest: obniżenie kosztów energii na odwilgocenie, zapewnienie bezpieczeństwa ekologicznego suszu, rozwój wysokowydajnych urządzeń do suszenia ziarna. Znaczne zintensyfikowanie procesu suszenia ziarna można uzyskać poprzez wykorzystanie efektu wibrowania obrabianego materiału przy jednoczesnym działaniu ozonu jako składnika suszenia, co dodatkowo obniża koszty energetyczne operacji i pozwala na uzyskanie wysokiej jakości materiału końcowego . W artykule zbadano eksperymentalnie parametry energetyczne opracowanego kompleksu wibro-ozonowania w zależności od parametrów modowych badanego procesu suszenia surowców zbożowych.
EN
In this research paper, the problem of studying the effectiveness of ozone in the process of water treatment was considered. In the course of the scientific work, a review of domestic and foreign literature was conducted; its advantages and disadvantages were considered. The research paper presented the theoretical and practical methods of water purification with ozone. The main factors influencing the efficiency of the technology in the process of water purification were also considered. It was established that as a technological method of water purification, the efficiency of the ozonation process includes not only the cost of electricity, but also the efficiency of its mixing, ozone dissolution in treated water. In addition, special attention is paid to the final stage of mixing the ozone-air mixture with treated water. From the results obtained, it can be seen that after primary ozonation, the concentrations of chromium, oxidation of permanganate, iron, petroleum products, metal ions and other pollutants significantly decreased. During further water purification, organic and inorganic pollutants are removed in the future (completely or up to the requirements of the standard). However, calcium, magnesium, sulfates, chlorides, pH value, alkalinity and hardness practically do not change. The water quality after primary ozonation according to bacteriological indicators met the requirements of the standard.
3
Content available remote Methods for measuring ozone concentration in ozone-treated water
EN
The ozone measurements are gaining in importance as the area of environmental ozone applications to liquids and especially to water grows. Some a few methods can be enumerated, and each of them has only limited area of applications. The comparison of the methods shows that there still is a need for rugged, reliable, ozone-specific, direct measurement methods and sensors for measuring ozone concentration in ozonated water.
PL
Przyrządy i metody do pomiaru stężenia ozonu w cieczach, a zwłaszcza w wodzie, nabierają coraz większego znaczenia w miarę rozszerzania się obszarów zastosowań ozonu ze względu na ochronę środowiska. Porównano kilka współcześnie stosowanych metod i wykazano, że każda z nich posiada tylko ograniczony obszar przydatności.
EN
High concentration of ozone, up to 400 µg/m3, was observed in the air of an urban area during summer 2003 in Wroclaw, south-western Poland. In ozone episods, commonly lasting three days, its peak concentration increased from the first to the third day. This coincided with an increasing atmosphere instability near the ground after sunrise and a weaker nocturnal inversion in the following days. Four-hour averaged ozone concentration (09:00-13:00) showed positive association with the height of mixing layer and negative one with the environmental lapse rate in the surface layer at noon. These two independent variables explained 61% of a total variation with a standard error of 26 ?g/m3. It was not a local traffic activity that was responsible for high ozone concentration, but a positive feedback between the weakening of a high-pressure system and the increasing importance of vertical mixing (e.g., higher efficiency of ozone production, vertical transport of aged air masses from upper altitudes), which was supported by well-documented episodes and backward trajectory analysis.
PL
Podczas lata 2003 obserwowano duże stężenia ozonu, do 400 µg/m3, w atmosferze Wrocławia, południowo-zachodnia Polska. Epizody te trwały zazwyczaj trzy dni, a maksymalne stężenia wzrastały sukcesywnie od pierwszego do trzeciego dnia. Zachowanie takie było zbieżne ze zwiększeniem się chwiejności atmosfery po wschodzie słońca i słabszą inwersją radiacyjną podczas kolejnych dni. Średnie 4-godzinne stężenie ozonu (09:00 - 13:00) było dodatnio skorelowane z wysokością warstwy mieszania, a ujemnie -z gradientem temperatury w warstwie powierzchniowej w południe. Te dwie zmienne niezależne tłumaczyły 61% całkowitej zmienności stężeń ozonu z błędem standardowym 26 u.g/m3. Wyjaśnieniem dużych stężeń ozonu nie była lokalna emisja gazów spalinowych ze środków transportu, lecz dodatnie sprzężenie między słabnięciem systemu podwyższonego ciśnienia a wzrostem znaczenia procesów mieszania (m.in. wyższa wydajność tworzenia ozonu w atmosferze miejskiej, pionowy transport dojrzałych mas powietrza z dużych wysokości), co zostało potwierdzone przez dobrze udokumentowane epizody i analizę trajektorii wstecznych.
PL
Zbadano możliwości zastosowania różnych typów sieci neuronowych do modelowania stężenia ozonu przy powierzchni ziemi. W obliczeniach wykorzystano dane zarejestrowane w 1996 r. na stacji pomiarowej monitoringu powietrza w Zabrzu. Analizowany zbiór danych stanowiły zmierzone w godzinach dziennych wartości stężeń 03, NO." natężenia promieniowania słonecznego, temperatury i prędkości wiatru uśrednione w okresach 60-minutowych. Do utworzenia modeli regresyjnych, uzależniających stężenie ozonu od stężenia NO" temperatury, natężenia promieniowania słonecznego i prędkości wiatru, wykorzystano sztuczne sieci neuronowe o strukturze perceptronu. W badaniach ograniczono się do trzech typów modeli neuronowych: liniowych, perceptronu trójwarstwowego, perceptronu czterowarstwowego. Jako kryterium oceny otrzymanych modeli przyjęto wartość pierwiastka z błędu średniokwadratowego RMSE, wynikającego z rozbieżności między wartościami obliczonymi a wartościami rzeczywistymi stężenia 03. Na podstawie przeprowadzonej analizy stwierdzono, że modele neuronowe wykorzystujące strukturę perceptronu trójwarstwowego i czterowarstwowego są zdecydowanie lepsze (dokładniejsze) od modeli liniowych. Dokładność modeli neuronowych wykorzystujących strukturę perceptronu trójwarstwowego i czterowarstwowego jest podobna. Liczba neuronów w warstwach ukrytych perceptronów nie decyduje o dokładności modelu. Prędkość wiatru może być pomijana w modelowaniu stężenia ozonu w godzinach dziennych.
EN
Possibility of neural networks application to the surface ozone concentration modelling was examined. The data gathered in 1996 at the air monitoring station in Zabrze (Upper Silesia, Poland) were used in calculations. The analysed data set was built of 60-minutes' averages of temperature, insolation and wind speed as well as 03 and NO, concentrations measured at the daytime hours. Neural networks were used for generation of multiple regression models, conditioning ozone concentration by temperature, insolation, wind speed and NO, concentration. Three types of neural networks were tested: linear, non-linear perceptrons with one hidden layer and non-linear perceptrons with two hidden layers. The value of root mean square error RMSE resulting from divergences between model input and real 03 concentration values was assumed as the criterion of each model estimation. It was stated that the non-linear models are decidedly better than the linear regression models. Accuracies of non-linear perceptron models with one and two hidden layers are similar. Number of neurons in hidden layers does not influence on model accuracy. Wind speed may be omitted as the input variable in neural models.
PL
Prognozowanie stężeń ozonu w przyziemnej warstwie atmosfery realizowane jest w oparciu o modele matematyczne uwzględniające przemiany fotochemiczne zanieczyszczeń. O przydatności modelu matematycznego do prognozowania stężeń zanieczyszczeń wtórnych (np. ozonu) w analizowanym obszarze świadczy przede wszystkim jego skuteczność, objawiająca się dużym współczynnikiem zgodności wyników obliczeniowych z wartościami pomiarowymi, obserwowanymi na stacjach kontroli jakości powietrza. W artykule przedstawiono analizę dokładności wyników prognozowania stężeń opartą na ocenie jakościowej i ilościowej (statystycznej). Ocenę dokładności wyników prognozowania stężeń ozonu przeprowadzono na przykładzie danych pochodzących z eksperymentu zrealizowanego w dniach 1-3 lipca 1993 r. w Nowym Sączu.
EN
Ozone concentrations in the ground atmospheric layer forecast is realized basing on the mathematical models taking into consideration the photochemical transformations of the air pollutants. Usefulness of the mathematical model for the forecast of the secondary pollutant (for example ozone) concentrations in a tested area is testified by its efficacy. The efficacy is revealed by good coefficient compliance between the computational results and the measurements (the values observed in the air pollution control stations). In the paper an accuracy analysis of the forecast results basing on the qualitative and the quantitative (statistic) estimation were presented. The accuracy estimation of the ozone concentration forecast was carried out for the hypothetical data derived from the Nowy Sącz experiment, 1-3 July, 1993.
PL
Badania przeprowadzono na podstawie danych zarejestrowanych w okresie 1995-1996 na stacjach sieci monitoringu powietrza w Krakowie. W obliczeniach wykorzystano dane zebrane w postaci 2-godzinnych średnich stężeń O3 i NOx. Sporządzono tygodniowy przebieg zmienności stężeń zanieczyszczeń i ozonu dla jednej stacji monitoringu powietrza pracującej w centrum miasta (Rynek) oraz dla drugiej stacji usytuowanej na przedmieściach (ul. Balicka), oddzielnie dla sezonu grzewczego i niegrzewczego. Stwierdzono dla obu sezonów, że w niedziele, w porównaniu z innymi dniami tygodnia, na obu stacjach pomiarowych występuje efekt podwyższenia minimalnych dobowych stężeń ozonu. Podobny, chociaż znacznie słabszy, efekt może wystąpić w soboty i poniedziałki.
EN
Summary Analysis was performed of data derived from the air monitoring network in Cracow in the years 1995-1996. 2-hours' averages of O3 and NOx concentrations were used in the calculations. The weekly courses of these pollutants concentrations were analyzed for two chosen measuring stations, separately for the heating season and for the non-heating one. It was assumed that on Sundays in comparison with the other weekdays the effect of relative increasing of the daily ozone concentration minimum was appeared in both measuring stations. Similar, but considerably weaker effect, may occur on Saturdays and Mondays.
PL
Wykorzystano dane pochodzące z lat 1994--1996, zarejestrowane w postaci 30-minutowych stężeń na kilku stacjach monitoringu powietrza pracujących w Aglomeracji Górnośląskiej oraz w rejonie Kędzierzyna-Koźla. Analizie poddano dobowe zmiany wartości stężeń utleniaczy atmosferycznych O3, NO2 i Ox (Ox = O3 + NO2). W pracy porównano zmiany stężeń O3 i Ox w epizodach dobowych w celu rozstrzygnięcia, czy na terenach zurbanizowanych stężenie Ox jest, w porównaniu ze stężeniem samego O3, wielkością lepiej opisującą potencjał oksydacyjny atmosfery i fotochemiczne zagrożenie środowiska. Analizując zmiany stężeń obu gazów podczas wybranych epizodów wykazano, że poziom stężenia ozonu może być mylącym kryterium oceny zagrożenia środowiska. Wskazano również możliwość powstawania w silnie zanieczyszczonym spalinami powietrzu dużych ilości NO2 według innego mechanizmu niż utlenianie NO przez ozon lub rodniki nadtlenkowe.
EN
Analysis was performed of data gathered in years 1994-1996 at some measuring stations in Upper Silesia, Southem Poland. Diurnal changes of concentrations of atmospheric oxidants like O3, NO2 i Ox (Ox = O3 + NO2) were analysed. The concentration changes of O3 and Ox in twenty-four hours episodes were compared in order to decide, whether Ox concentration is, in comparison with O3 concentration, the better parameter describing oxidation potential of atmosphere and photochemical threat of environment in the urban areas. Analysis of concentration changes of both of the oxidants during chosen episodes shows, that level of ozone concentratian can be a wrong criterion of estimation of threat to environment. It was pointed the possibility of NO2 formation in fumes according to other mechanism than oxidatian with ozone or peroxide radicals.
PL
Przedstawiono analizę danych, pochodzących z sieci automatycznego Regionalnego Systemu Monitoringu Zanieczyszczeń Powietrza działającego na obszarze aglomeracji górnośląskiej. Dokonano obliczeń częstości przekroczeń dopuszczalnych wartości stężenia ozonu na wybranych stacjach monitoringu powietrza pracujących w latach 1994-1998. Uwzględniono dopuszczalne wartości stężenia ozonu obowiązujące do maja 1998 r. oraz obowiązujące obecnie. Wykazano, że na terenach oddalonych od większych źródeł emisji (Kuźnia Nieborowska, Olkusz) występuje wyższa częstość przekroczeń wartości dopuszczalnych niż na terenach silnie zurbanizowanych (Katowice, Zabrze).
EN
The data obtained from selected air monitoring measurement stations located in agglomeration of Upper Silesia were analyzed. They were collected in the period 1994-1998. In this work the evaIuation of permissible values of O3 concentration was carried out. Comparison of exceeds of permissible concentration was made based on present and previous regulations in Poland. Results presented in the article suggested that previous regulations were more restrictive than the new ones. The higher frequency of standards exceeds was noticed in "dean" sites (Kuźnia Nieborowska, Olkusz) than in typical urban areas (Katowice and Zabrze).
PL
Badania przeprowadzono na podstawie danych pochodzących z sieci monitoringu powietrza w województwie katowickim z okresu od 1994 do 1996 roku. W obliczeniach wykorzystano dane zebrane w postaci 2-godzinnych średnich stężeń 03, NOx, CO, S02 oraz temperatury i natężenia promieniowania słonecznego. Sporządzono tygodniowy przebieg zmienności stężeń zanieczyszczeń i ozonu w wybranych stacjach kontrolno-pomiarowych, oddzielnie dla sezonu grzewczego i niegrzewczego. Stwierdzono, że w niedziele, w porównaniu z innymi dniami tygodnia, na wszystkich stacjach pomiarowych występuje efekt podwyższenia minimalnych dobowych stężeń ozonu, szczególnie dobrze widoczny w sezonie niegrzewczym. Podobny, chociaż znacznie słabszy efekt, występuje w soboty i poniedziałki.
EN
Studies were performed on the ground of data derived from the regional air monitoring network in Katowice. 2-hours' averages of 03, NOx, CO, S02 concentrations as well as temperature and solar radiation from the period 1994-1996 were used in calculations. The weekly courses of these pollutants concentrations were prepared for three chosen measuring stations, separately for the heating season and for the non-heating one. It was assumed that on Sundays in comparison with the other weekdays the effect of relative increasing of the daily ozone concentration minimum was appeared in all measuring stations. That is apparent particularly in the non-heating season. Similar, but considerably weaker effect, occurs on Saturdays and Mondays.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.