This article presents the results of studies relating to the possibility of the practical use of the preliminary hazard analysis method to assess the risk of damage to the telecommunications copper access network. Use of the PHA method allows the identification and evaluation of risk factors; it enables the comparison of the risk of damage to components of the telecommunications copper access network located in different geographical areas. This generates the possibility of the effective application of a comparative analysis (including the service quality) by the operator for different network areas. The method also allows the setting of benchmarks for improving the effectiveness of the technical services of the operator.
PL
W artykule przedstawiono wyniki badań własnych dotyczących możliwości praktycznego wykorzystania metody Preliminary Hazard Analysis (PHA ) do oceny ryzyka wystąpienia uszkodzeń miedzianej dostępowej sieci telekomunikacyjnej. Zastosowanie metody PHA pozwala na identyfikację i ocenę czynników ryzyka. Umożliwia porównywanie ryzyka uszkodzeń komponentów miedzianej dostępowej sieci telekomunikacyjnej zlokalizowanej na różnych obszarach geograficznych. Generuje to możliwość skutecznego stosowania analizy porównawczej (m.in. jakości obsługi) przez operatora dla różnych obszarów sieci. Pozwala także na benchmarking w zakresie poprawy efektywności m.in. pracy służb technicznych operatora.
EN
The results of simulation tests concerning the cooperation of the nonlinear load with the power system are presented. In numerical experiments we have taken data from the real systems, including the cable and overhead lines. In practice the nonlinear load of high power may be supplied by the overhead or cable lines. The paper presents the comparative analysis, how the applied type of the line influences the level of distortion of the voltages and currents in the power system. The values of the higher harmonics of the voltages and currents as well as THD have been determined in the paper. These values have been estimated for the beginning and ending terminals of the overhead and cable lines supplying the nonlinear load of the inductive character concerning the cooperation of the filtering compensating device and the nonlinear load of high power. All experiments have been performed using MicroCap-8 program. In the paper we have included he exemplary results of the numerical calculations.
EN
The monitoring of the temperature makes possible the introduced to exploitation system VALCAP of the NKT Cables company. The system measures the temperature along the conductor with the regard external temperature (only for overhead lines). The paper presents the applied in the practice method of the analysis of the acceptable load of cable or the conductor of the overhead line in dependence from stepping out external conditions.