Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  osady żelaziste
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This work presents preliminary results of mineralogical, geochemical and microbiological investigations carried out in the Polish part of the Muskau Arch. As a result of sulphide oxidation in this abandoned mining area, highly acidified Fe-rich waters have been formed. Ferruginous precipitates composed mainly of schwertmannite, goethite, jarosite and gypsum accompany them. Both the water chemistry and the rate of the sediments formation vary significantly due to seasonal weather changes and microbiological activity.
PL
W pracy przedstawiono wstępne wyniki badań mineralogicznych, geochemicznych i mikrobiologicznych wykonywanych w polskiej części Łuku Mużakowa. W wyniku utleniania siarczków w tym opuszczonym obszarze górnictwa tworzą się wody bardzo zakwaszone oraz bogate w żelazo. Osady żelaziste składają się głównie z schwertmannitu, goethytu, jarosytu oraz gipsu. Zarówno chemia wody oraz tempo powstawania osadów różnią się znacząco ze względu na sezonowe warunki pogodowe i aktywność mikrobiologiczną.
EN
A rural water supply system was contaminated with crude oil along a length of several kilometres. The tap water had a disagreeable odour and carried oil spills on its surf ace. Prewashing with water was found to be insufficient. Analysis of pipe samples showed that crude oil had occluded on the iron-containing incrustation. On the basis of laboratory tests, a procedure was established for the removal of the oil-contaminated incrustation layer. The procedure involved a solution which was made up of NaHSO4, TPF and Roksol MS (a mixed nonionic and anionic surfactant). The pipeline was washed stepwise. The said solution was passed to particular pipe sections, and mixing was provided via air supply. After 24 hours of treatment, the pipe section was rinsed, and the effluent was collected in tanks before it was sent to the wastewater treatment plant. The rinsing procedure was discontinued after the concentration of anionic and nonionic surfactans decreased to the value of 0.1 g/m[3] and 0.2 g/m[3], respectively, and the tap water was free of benzene and of the typical crude oil odour.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.