Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  optimal sizing
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article discusses a method of assessing the of dependence of the number of batteries that would be needed to achieve energy balance in distributed generation systems with wind turbines on ambient temperature and on the error involved in predicting the parameters of wind flow (wind speed). To describe the relationship between current rate and capacity in a given current range, Peukert’s law is used. Dependence of the Peukert's constant on ambient temperature for the lead-acid battery HZB12-180FA is calculated. Taking the lead-acid battery and wind turbine VE-2 as a reference, dependence of area of controlled operation of the battery on the wind speed forecasting error is calculated. The technique of considering ambient temperature, depth of discharge, and wind speed forecasting error when deciding the size of energy storage of the balancing system (the number of batteries and their capacity) is provided. A family of curves representing the dependence of the number of batteries constituting the balancing system on the ambient temperature and the wind speed forecasting error are presented. It is shown that as the wind speed forecasting error increases from 0% to 15% and the ambient temperature decreases from 20 °C to 20 °C, the number of batteries should be increased by approximately 2.81 times in order to maintain the same area of controlled operation of a battery.
EN
This paper presents the optimal sizing of PV/Wind/Fuel Cell/Battery Hybrid Energy System for energizing a Small Scale Industrial Application or a village domestic load of 200 kW. HOMER software is used for simulation of the complete system. The solar radiation data and wind speed data used in this paper are for the place of Coimbatore, Tamil Nadu, India which is located 11.0183° N longitude and 76.9725° E latitude. The optimized sizes of components of Hybrid Power System (HPS) are found based on Levelised Cost of Energy (LCE) and total Net Present Cost (NPC). The results are presented and compared for five different combinations of HPS components. Suggestions are also presented to choose the low cost system which produces energy at low LCE.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.