Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  optical profilometer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article concerns the evaluation of the possibility of using the optical profilometry method in the analysis of the destruction process of acrylic coatings exposed at a climate station in an industrial-urban atmosphere. It was found that the observed changes do not allow to clearly assess the durability of the tested coatings. It seems that the method used may play a supporting role in assessing the quality of the coatings because the surface maps show the number and size of pores in the coating. Therefore, this method can be used, for example, to help determine the optimal parameters of the coating process (e.g. spray pressure).
PL
Artykuł dotyczy oceny możliwości wykorzystania metody profilometrii optycznej w analizie procesu destrukcji renowacyjnych powłok akrylowych przeznaczonych dla przemysłu motoryzacyjnego eksponowanych na stacji klimatycznej w atmosferze przemysłowo-miejskiej. Stwierdzono, że zaobserwowane zmiany nie pozwalają jednoznacznie ocenić trwałości badanych powłok. Wydaje się, że zastosowana metoda może odgrywać rolę pomocniczą w ocenie jakości powłok, ponieważ mapy powierzchni wyraźnie pokazują liczbę i wielkość porów w powłoce. Można więc zastosować tę metodę przykładowo jako wspomagającą ustalenie optymalnych parametrów procesu nakładania powłok (np. ciśnienia natrysku).
PL
W pracy badano wpływ doboru natężenia oświetlenia na wyniki pomiarów parametrów struktury geometrycznej powierzchni, jak również wpływ tegoż natężenia na liczbę punktów niezmierzonych z wy korzystaniem interferometru światła białego Talysurf CCI Lite. Badaniu poddano powierzchnie próbek: anizotropowe, izotropowe oraz mieszane. Natężenie oświetlenia zmieniano w zakresie od 10 do 90%, każdorazowo co 5%. Określono wpływ zmiany natężenia oświetlenia na jakość pomiaru oraz na zmianę wartości parametrów struktury geometrycznej powierzchni. Parametr Smr oraz parametry z grupy cech są najbardziej wrażliwe na zmianę natężenia oświetlenia, nawet jeśli liczba punktów niezmierzonych nie przekracza 10%.
EN
Ten isotropic, anisotropic and mixed surface topographies were analysed. Surface measurements were made using white light interferometer Talysurf CCI Lite. All surfaces were measured with different light intensity. Light intensity was changed in the range of 10%-90% every time at 5%. Parameters from ISO 25178 group were calculated. Parameters were calculated using the software Talymap Gold, version 6.0. Influence of light intensity on the change of surface topography parameters was analysed. The functional parameter Smr and feature parameters are the most sensitive to light intensity even if number of non-measured points was smaller than 10%.
EN
Several isotropic and anisotropic surface topographies were analysed. Surface measurements were made using white light interferometer Talysurf CCI Lite, version 2.8.2.95. All surfaces were measured with different light intensity. Light intensity was changed in the range 10%–90% every time at 5%. After measurement each surface was levelled and non-measured points were filled up. Parameters from ISO 25178 group and parameters from the Sk family were calculated. Parameters were calculated using the software Talymap Gold, version 6.0. Influence of light intensity on the change of surface topography parameters was analysed.
PL
W pracy badano wpływ doboru natężenia oświetlenia na wyniki pomiarów parametrów chropowatości, jak również wpływ tegoż natężenia na ilość punktów niezmierzonych z wykorzystaniem interferometru światła białego Talysurf CCI light. Badaniu poddano zarówno próbki anizotropowe (szlifowane), jak i izotropowe (kulowane). Natężenie oświetlenia zmieniano w zakresie od 10 do 90% każdorazowo co 5%. Określono wpływ zmiany natężenia oświetlenia na jakość pomiaru oraz na zmianę wartości parametrów chropowatości.
PL
W pracy przedstawiono wyniki badań odporności na korozję elektrochemiczną drutów wykonanych ze stali nierdzewnej X10CrNi 18-8 przeznaczonych dla protetyki stomatologicznej i chirurgii twarzowo-szczękowej. Testy potencjodynamiczne realizowano w roztworze sztucznej śliny. Dokonano oceny wpływu odkształcenia w procesie ciągnienia oraz modyfikacji powierzchni na właściwości korozyjne drutów. Za pomocą profilometru optycznego przeprowadzono pomiar cech geometrycznych drutów po badaniach korozyjnych.
EN
The study presents the results of electrochemical corrosion resistance tests of wires made of stainless steel X10CrNi 18-8 for prosthodontic and facial and dental surgery. Potentiodynamic tests were performed in artificial saliva solution. The influence of strain in drawing process and surface modification on wire corrosion characteristics were evaluated. Optical profilometer was used for measurement of geometrical features of wires after corrosion tests.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.