The results of measurements of Kerr constant in castor oil, obtained by dynamic-polarimetric method are presented. Variable optical path length and four measurement setup configurations were used. They differed by the orientation of polarizer and of quarterwave plate and therefore they were non-equivalent when other, unwanted effects occurred. It was shown that the Kerr constant measurement performed with use of only one system configuration and one length of optical path may be strongly affected by other effects, however taking the arithmetic mean of two results obtained from appropriate system configurations significantly reduces this error. Theoretical dependences were fitted to the experimental results, which allowed for approximation of other constants, like dichroism, linear birefringence and optical activity induced by external electric field (electrogyration).
PL
Przedstawiono wyniki pomiarów stałej Kerra w oleju rycynowym metodą polaryzacyjno-optyczną dla różnych długości drogi światła w próbce przy czterech konfiguracjach pomiarowych, nierównoważnych pod względem wpływu innych niepożądanych efektów, które różnią się orientacjami polaryzatora i płytki ćwierćfalowej. Pokazano, że pomiar stałej Kerra przeprowadzony dla tylko jednej konfiguracji pomiarowej przy jednej długości drogi światła w próbce może być obciążony znacznym wkładem kilku innych niepożądanych efektów, jednakże obliczenie średniej arytmetycznej z pomiarów w dwóch odpowiednio dobranych konfiguracjach pomiarowych pozwala na znaczne zredukowanie błędów pomiarowych. Do wyników doświadczalnych dopasowano zależności teoretyczne, co oprócz pomiaru stałej Kerra pozwoliło także na zgrubne oszacowanie innych wielkości takich jak dichroizm, liniowa dwójłomność i aktywność optyczna indukowana polem elektrycznym (elektrożyracja).
EN
A technique for measurement of very weak linear birefringence of the order of 10-7 and dichroism in liquids is proposed. The method is based on the polarimetric technique. A characteristic feature is that the experimental setup enables the measurement of linear birefringence combined with electro-optic effect as well as the measurement of dichroism combined with electro-optic effect. The combination of the effect which does not show rapid changes with the effect which depends on alternating electric field allows to improve the sensitivity of the method (in comparison to the earlier static method). This was achieved by use of lock-in amplifier that measures only the selected harmonic with very high selectivity. The theoretical considerations are illustrated by the results of measurements for castor oil.
PL
Zaproponowano metodę pomiaru bardzo słabej dwójłomności liniowej rzędu 10-7 i dichroizmu w cieczach opartą na technice polaryzacyjno-optycznej. Cechą charakterystyczną metody jest taki wybór konfiguracji układu, w którym możliwy jest pomiar kombinacji dwójłomności liniowej i efektu elektro-optycznego oraz kombinacji dichroizmu z efektem elektro-optycznym. Połączenie efektów niewykazujących szybkich zmian w czasie z efektem zależnym od zmiennego pola modulującego pozwoliło na poprawę czułości metody (w porównaniu do starszej metody statycznej) przez zastosowanie woltomierzy typu lock-in, które mierzą z wysoką selektywnością tylko wybraną harmoniczną. Rozważania teoretyczne zostały zilustrowane wynikami pomiarów dla oleju rycynowego.