Opisano konstrukcję atmosferycznych zbiorników produktów naftowych oraz warunki ich eksploatacji w warunkach obciążeń katastroficznych, stale stosowane na te zbiorniki, łącznie ze stalami o wysokiej granicy plastyczności – HSS, spawalność stali HSS oraz systemy monitorowania w czasie rzeczywistym jakości złączy konstrukcji zbiorników.
EN
The paper presents the design of atmospheric storage tanks for petroleum products and their operating conditions in catastrophic conditions, the steels used for the storage tanks, including high-yield-strength steels – HSS, the weldability of HSS steels, and systems for the real-time monitoring of the quality of tanks welded joints.
EN
The aim and scope of this work included the design and practical implementation of a digital monitoring system for the polyacrylonitrile (PAN) fibre spinning process line used for the creation of different PAN based fibres doped with silver (Ag), polyaniline (PANI), carbon nanotubes (CNT) and 2,3,5-triphenyltetrazolium chloride (TTC). After the collecting and processing of process parameters, including bath temperatures and the rotational speed of the feeding-receiving points, available in the form of digital data, they were compared with the appearance of fibres obtained (their surface structure and cross-section shape) and with the results of the fibre specific strength (WtP). Archiving of speed and temperature measurement data allowed to create a database combining the process parameters with the parameters of the fibres obtained. Online monitoring of the parameters enabled programmable change of the speed and temperature in important parts of the process in order to develop appropriate production profiles.
PL
Celem i zakresem prac było zaprojektowanie i praktyczna realizacja cyfrowego systemu monitorowania linii technologicznej przędzenia włókien poliakrylonitrylowych (PAN) używanej do tworzenia różnych włókien opartych na PAN domieszkowanych srebrem (Ag), polianiliną (PANI), nanorurkami węglowymi (CNT) i chlorkiem 2,3,5-trifenylotetrazoliowy (TTC). Po zebraniu i przetworzeniu parametrów procesu, w tym temperatur kąpieli i prędkości obrotowych punktów rozciągających, dostępnych w postaci danych cyfrowych, porównano je z wyglądem uzyskanych włókien (ich strukturą powierzchni i kształtem przekroju poprzecznego) oraz z wynikami wytrzymałości właściwej włókien (WTP). Archiwizacja danych pomiaru prędkości i temperatury pozwala na stworzenie bazy danych łączącej parametry procesu przędzenia z parametrami uzyskanych włókien. Monitoring parametrów on-line umożliwia programowalną zmianę prędkości i temperatury w ważnych częściach procesu w celu opracowania odpowiednich profili produkcyjnych.
PL
W artykule opisano podstawy nowoczesnego systemu dedykowanego pod wentylatory międzystopniowych chłodnic powietrza, rekuperatorów w obiegach turbozespołu gazowego oraz chłodniach wentylatorowych w obiegach parowych. System ten opiera się na numerycznych algorytmach, których zadaniem jest monitorowanie pracy oraz określenie stopnia degradacji najbardziej wytężonych elementów konstrukcji. Rozszerzeniem kompetencji jest dobór optymalnych warunków pracy, sprzężonych ściśle z aktualnymi parametrami obiegu turbozespołu gazowego. System wyposażony jest w autorskie procedury będące wynikiem długoletnich prac wykonywanych w IMP PAN w Gdańsku.
EN
In this papers I have been presented fundamental of news monitoring system dedicated by the fans of intercooler and recuperative heat exchangers from the cycle of gas turbine and cooling tower from cycle of steam turbine. This system based on the numerical algorithm. The goal of this algorithm is monitoring work and calculation level of damage highly loaded elements parts in machines. Extension of the competences it is selection of optimal boundary of works, which is precisely linked from actual parameters of thermodynamic cycle. System is used by authorial procedures as a result of many years worked in IMP PAN.
EN
High temperature (low oxygen) corrosion processes in coal-fired boilers are intensified primarily by the use of low-emission (NOx) combustion techniques, that are associated with production of a reducing gas atmosphere near evaporator walls. For over 10 years a diagnostic system for corrosion risks determination was developed, based on continuous measurement of the composition of the flue gas in the boundary layer and artificial intelligence techniques. This paper presents the experience with the implementation of such a diagnostic system on the OP-230 hard coal fired boiler to identify the corrosion hazard of one of the evaporator walls. The obtained results indicate that it is possible to significantly simplify the measuring system by reducing the number of measurement points on the boiler wall which reduces costs of installation and exploitation. This is possible through the use of neural networks to visualize the measurement results. Comparisons of the O2 and CO concentration maps in the boundary layer obtained from measurements at 26 measurement points and results from the Rachel software based on neural network performance and 5-point measurement showed a high compatibility of obtained results. At present, on-line electrical resistance corrosion probes are included in the monitoring system to allow an assessment of the actual corrosion rate of entire evaporator tubes.
PL
Monitoring on-line wysokonapięciowych izolatorów przepustowych nie znalazł dotychczas powszechnej akceptacji z powodu niepewności mierzonych wskaźników izolacji. Integracja monitoringu z systemami stacyjnymi znacznie poprawia uzyskiwane rezultaty. W systemach zintegrowanych możliwe jest wdrażanie rozbudowanych algorytmów monitorowania, uwzględniających zdarzenia stacyjne. Dokładniejsze pomiary umożliwiają wnioskowanie o stanie izolatorów przepustowych, wykorzystujące korelacje zmian współczynnika strat dielektrycznych tgδ oraz temperatury.
EN
The high voltage bushing on-line monitoring has not found universal acceptance so far, because of high uncertainty of measured insulation parameters. The monitoring integration in station systems greatly improves the obtained results. It is possible to implement complex monitoring algorithms in integrated systems, taking into account the substation events. The new conclusion rules can be also elaborated basing on the power dissipation factor and temperature correlation.
EN
The research about on-line monitoring of transformer winding deformation based on Short-Circuit Reactance is studied, then a method is put forward to calculate the leakage reactance of power transformer quickly. The equivalent resistance can be got from the ratio of voltage difference and current at the peak of current. Also, the equivalent inductance can be got from the ratio of voltage difference and current differential when current is zero. At the same time, it is helpful for improving the resolution of the algorithm to the maximum precision of AD acquisition card by magnifying the voltage difference of primary and secondary voltage before being gathered to AD card. The system designed by the two technologies above is tested on the laboratory platform and a criterion is proposed to help to judge the state of winding. The article provides an effective method to monitor on-line monitor the winding deformation of transformer.
PL
W artykule przedstawiono metodę monitorowania w trybie on-line deformacji uzwojeń transformatora. Do analizy wykorzystano pomiar reaktancji w stanie krótkotrwałego zwarcia. Określana jest też zastępcza rezystancja i indukcyjność uzwojenia. Badania eksperymentalne potwierdziły skuteczność metody.
EN
This paper presents a distributed measuring system for on-line monitoring of dielectric loss factor tan δ, and capacitance of HV apparatus. The method employs the Discrete Fourier Transform (DFT) which is performed on the scaled down analog voltage and current signals obtained using digital signal processing (DSP) technology. The measuring unit of the on-line monitoring system takes a series of measures in the hardware circuit design to improve the effectiveness of the DFT algorithm. The lab test results of measuring unit show that the measuring unit has high precision of measurement based on the DFT method. Field tests at a regional substation to evaluate the insulation of two groups of 220kV current transformer units using the developed system.
PL
W artykule opisano system pomiaru rozproszonego do monitorowania on-line współczynnika strat dielektrycznych i pojemności w aparatach HV. W metodzie wykorzystano Dyskretną Transformatę Fouriera. W celu poprawy dokładności i skuteczności DFT, dokonywana jest seria pomiarów. Wyniki badań laboratoryjnych oraz w rzeczywistej podstacji, wykazały wysoką precyzję rozwiązania.
EN
This paper describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1 % for dissipation factor. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and dissipation factor of HV bushings. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
PL
Artykuł opisuje nowe metody pomiaru on-line pojemności i współczynnika strat przepustów wysokonapięciowych na potrzeby, monitorowania przepięć w sieci i wyładowań niezupełnych w transformatorach energetycznych. Według statystyk awaryjności przepusty WN są jedną z głównych przyczyn awarii transformatorów, co motywuje operatorów do ciągłego monitoringu on-line stanu układów izolacyjnych. Na potrzeby wiarygodnej diagnostyki wymagana jest dokładność pomiaru pojemności rzędu 5 pF i współczynnika strat rzędu 0,1%. Aby uzyskać taką rozdzielczość, wskutek braku symetrii w sieci, nie wystarczy względne porównanie prądów mierzonych w zaciskach pomiarowych w przepustach trzech faz. Dodatkowo, ten sposób pomiaru nie pozwala identyfikować procesu starzenia przebiegającego w trzech fazach ze zbliżonym tempem. W artykule przedstawiono metodę pomiaru rzeczywistych wartości pojemności i współczynnika strat przepustów WN. Pozwala ona uzyskać dokładność podobną do pomiarów off-line nawet w warunkach eksploatacyjnych. Wyładowania niezupełne są wczesnym wskaźnikiem zbliżającego się przebicia w izolacji WN. Ich pomiar na zacisku przepustu WN umożliwia wykrycie defektów w izolacji przepustu oraz transformatora. Podobnie jak w pomiarach off-line, rozróżnienie zakłóceń od rzeczywistych wyładowań wewnętrz izolacji jest kluczem do poprawnej diagnostyki. Opisano strategie czułego pomiaru wyładowań niezupełnych w warunkach on-line, z uwzględnieniem zakresu UHF.
EN
Light and Water are often associated with rainbows - inspiring songs..., but normally not with information. But indeed - a lot of information concerning organic impurities is hidden in this system. COD and TOC parameters are consisting of humic substances: proteins, detergents and other chemical compounds of households, tannins / lignins of the paper industry, organic impurities of the chemical industry and carbohydrates of dairies. Most of these substances can be measured by UV - spectroscopy. The ensemble of all these substances leads to a spectrum with an absorption of about 254 nm. This absorption is measured as the ISO/DIN SAC = Spectral Absorption Coefficient. New continuously working on-line probe systems are able to measure this SAC and the integral absorption close to 254 nm. This scanning UV/VIS - probe offers you an individual signal which is very close to the COD and TOC depending on your wastewater. The resulting parameters offer the advantage of delivering on-line data within minutes. When problems are signalled, event-triggered samples can be taken by automatic samplers for further detailed analysis and diagnosis, e.g. river - monitoring or outlet - monitoring of a WWTP. However, the range of possible applications is not confined to sewage outlets. This probe system measures a useful parameter at nearly each step of a wastewater treatment process. Environment friendliness, rapid availability in continuous operation, ease of use, flexibility, the absence of sample pre - treatment and the resulting avoiding of errors and costs are strong arguments for this system. The instruments and their investment costs should automatically (more than) pay for themselves by skilful, active utilisation of the information obtained. Somewhere, after the treatment, water is blue...