PL
Przeprowadzono ocenę emisji zanieczyszczeń z kotłów opalanych węglem, biomasą, gazem ziemnym, lekkimi olejami opałowymi oraz z pomp ciepła. Wyliczono całkowite zużycie paliwa do wytwarzania energii oraz wielkość emisji zanieczyszczeń towarzyszącej procesowi spalania. Najniższą emisję obserwowano w przypadku kotła na gaz ziemny.
EN
Pollutant emission anal. was carried out for coal-fired, biomass-fired, natural gas or light fuel oil-fired boilers and a heat pump. The total fuel consumption for generation primary and final energy and the emission of pollutants accompanying its combustion were calculated. The lowest emission was obsd. for supplying energy by using a natural gas boiler.
PL
W artykule przedstawiono wyniki analizy energetycznej dla domu jednorodzinnego. Zbadano wpływ zmiany lokalizacji na wielkość obciążenia cieplnego poddając analizie wspomniany wcześniej dom, zlokalizowany w różnych rejonach Polski. Łącznie zbadano sześć przypadków, dbając o to, aby wybrane lokalizacje znajdowały się w różnych strefach klimatycznych Polski. Na podstawie wielkości obciążenia cieplnego wybrano dwa skrajne przypadki, dla których dokonano dalszej analizy polegającej na określeniu rocznego zapotrzebowania cieplnego na cele grzewcze i przygotowania ciepłej wody, określeniu rocznego zużycia paliwa w zależności od rozpatrywanej technologii spalania tzn. technologia oparta o węgiel kamienny, olej opałowy lub gaz ziemny oraz kosztów zakupu paliwa. Kolejnym etapem pracy było określenie rocznych udziałów emisji poszczególnych związków szkodliwych m.in. CO2, SO2, NOx i metali ciężkich powstających ze spalenia w instalacji indywidualnej paliwa niezbędnego do zaspokojenia zapotrzebowania cieplnego dla omawianego domu. Zbadano również, jaki wpływ na ludzkie zdrowie oraz roślinność ma zaspokojenie potrzeb energetycznych tego budynku z zakładu elektrociepłowni. W celu oszacowania negatywnych efektów emisji zanieczyszczeń gazowych posłużono się programem EcoSense Web. Wartości wyrządzonych szkód przedstawiono w postaci monetarnej, jako koszty pokrycia lub naprawy zaistniałych szkód. Analizę zewnętrznych kosztów środowiskowych wykonano dla wybranych lokalizacji w Polsce, natomiast wyniki przedstawiono w dwóch wariantach tylko dla Polski oraz łącznie dla grupy krajów europejskich.
EN
In this article, the results of the energy analysis for a detached house are presented. Also, the impact of changing localization on a size of the heat demand was examined. The aforementioned house was analyzed in various parts of the Poland - altogether six cases were examined. All of the localizations were located in five different climate zones which we can meet in Poland. Based on the size of the thermal load, two extreme cases were selected. For this two cases, further analysis was made. The primary task of this analysis was to determine the annual heat demand for heating and domestic hot water needs. Annual fuel consumption has been calculated depending on the technology, such as boilers based on coal, heating gas oil or natural gas. Moreover, the assessment of fuel costs was performed. The next stage of the study consists of the determination of the annual emission of each harmful compounds. The harmful compounds including CO2, SO2, NOx and heavy metals, results from fuel combustion necessary to cover the heat demand for the house in the single installation of combustion. The impact on human health and crops was also examined. Influence on this factors was caused by producing energy requirement to cover analyzed building needs. The required energy is generated by CHP plant. EcoSense Web software were used to estimate the negative effects of the emission of pollutants. The value of damages is expressed by monetary costs as the cost of coverage or repair the damage. The analysis of external environmental costs was made for Poland with the distinction of the losses in Polish vicinity and the damage caused by all other analyzed areas.
EN
The paper presents an economic and energetic comparative analysis of a system with a heat pump and ground-source heat exchangers, and a conventional heating system relying on the combustion of natural gas. Tests were carried out between 2011 and 2014 in a house of 160m2 floor surface with an installed 8 kW heat pump, in a breakdown by individual heating seasons. Results demonstrated that heating a building using renewable resources is less expensive than a conventional gas heating system by about 48%, but more expensive in terms of investment costs by 33-40% (depending on the type of ground-source heat exchanger). Return on investment costs is achieved after about 5-7 years of heat pump use. On average, ca. 85.09 GJ of energy were generated during a single heating season, average consumption of electrical energy to support heat pump operation was ca. 5085 kWh, and the average cost of system use per heating season was ca. PLN 2881.
PL
Przedstawiono porównawczą analizę ekonomiczno-energetyczną systemu wyposażonego w pompę ciepła oraz gruntowe wymienniki ciepła oraz tradycyjnego systemu opartego na spalaniu gazu ziemnego. Badania dotyczyły budynku mieszkalnego o powierzchni 160m2, pompy ciepła o mocy 8kW i prowadzono je w okresie od 2011 do 2014 roku z podziałem na poszczególne sezony grzewcze. Uzyskane wyniki świadczą o tym, iż ogrzewanie budynku z wykorzystaniem źródeł odnawialnych jest tańsze w stosunku do tradycyjnego systemu gazowego o ok 48% lecz droższe w kwestii kosztów inwestycyjnych o 33-40% (w zależności od rodzaju wymiennika gruntowego). Zwrot kosztów inwestycyjnych następuje po ok 5-7 latach eksploatacji pompy ciepła. W ciągu jednego sezonu grzewczego pozyskano średnio ok. 85,09 GJ a średnie zużycie energii elektrycznej niezbędnej za posilania pompy ciepła wyniosło ok. 5085 kWh, a średni koszt eksploatacji systemu wyniósł w ciągu jednego sezonu grzewczego ok. 2881 PLN.
PL
W artykule przedstawiono podstawowe rozwiązania kotłowni gazowych możliwe do zastosowania w domach jednorodzinnych. Przeanalizowano wielkość zapotrzebowania na ciepło do produkcji ciepłej wody w przeciętnym domu jednorodzinnym, opisano też układy hydrauliczne kotłowni i współpracę źródła ciepła z układem przygotowania ciepłej wody.
EN
The paper presents basic solutions of gas boiler-rooms for one-family houses. The value of heat demand for hot water preparation in average one-family house is analysed. Hydraulic systems in boiler-room as well as cooperation between boiler and hot water preparation system are also shown in this paper.