Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  oddziaływanie sejsmiczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the results of punching shear values with reinforcement based on calculations of two and four storey cast–in–place reinforced concrete flat plate system buildings with spans of 4 and 7 m in accordance with Armenian, Russian, European and American building codes under seismic action. The effect of punching shear on both interior and edge columns was carried out. All calculations by LIRA, Design Expert and RCM ACI–builder softwares were implemented. In contrast to Eurocode 2 (EN 2) and American Concrete Institute (ACI), the building codes of the Republic of Armenia (SNiP) do not include the influence of bending moment in shear stress equation. To analyze the systems finite element method (FEM) was used. The results of comparison analyses shown that according to SNiP the shear stresses do not exceed the limit even without reinforcement, whereas by foreign standards the differences between peak shear stresses with reinforcement and permissible shear reinforcement are marginal. To conclude, in shear stress condition the internal bending moments have a significant role, especially in seismic regions.
PL
W artykule przedstawiono wyniki pomiarów wytrzymałości na ścinanie w oparciu o obliczenia dla dwu i czteropiętrowych budynków żelbetowych o rozpiętości 4 i 7 m, zgodnie z ormiańskimi, rosyjskimi, europejskimi i amerykańskimi normami budowlanymi, w strefie oddziaływań sejsmicznych. Przeprowadzono badania dotyczące przebicia zarówno dla słupów wewnętrznych, jak i narożnych. Wszystkie obliczenia wykonano w programach LIRA, Design Expert i RCM ACI–builder. W przeciwieństwie do Eurokodu 2 (EN 2) oraz American Concrete Institute (ACI) przepisy budowlane Republiki Armenii (SNiP) nie uwzględniają wpływu momentu zginającego na równanie dla naprężeń stycznych. Do analizy układów konstrukcyjnych wykorzystano metodę elementów skończonych (MES). Wyniki analiz porównawczych wykazały, że zgodnie z SNiP naprężenia ścinające nie przekraczają wartości granicznych nawet bez użycia zbrojenia, podczas gdy według norm obcojęzycznych różnice pomiędzy ekstremalnymi naprężeniami ścinającymi z użyciem zbrojenia a dopuszczalnym ścinaniem zbrojenia są marginalne. Podsumowując, dla warunków dotyczących naprężenia ścinającego wewnętrzne momenty zginające mają duże znaczenie, zwłaszcza na obszarach objętych oddziaływaniami sejsmicznymi.
EN
In this article, the seismic shakedown FEM analysis of reinforced concrete and composite spatial frame structures on the deformable foundation, taking into account the elastic-plastic and brittle behavior of structures elements, is presented. A foundation consists of group of the piles in the soil. The behavior of soil is described here using and the elastic half-space theory. The pile deformation model is assumed to be elastic-perfectly plastic, where the bearing capacity is determined by the results of testing the soils or the piles themselves. An example of seismic shakedown limit analysis is presented.
PL
W niniejszym artykule za pomocą metody elementów skończonych przedstawiona analiza przystosowania sejsmicznego przestrzennych układów ramowych na podłożu odkształcanym, biorąc pod uwagę sprężysto-plastyczne i kruche zachowanie elementów układu. Podłoże składa się z grupy pal w gruncie. Grunt zachowuje się jako sprężyste ciało półprzestrzenne. W modelu odkształcenia pali założono zachowanie idealnie sprężysto-plastyczne, a nośność graniczna pali określa się na podstawie wyników badań podłoża lub samych pal. Przedstawiono przykład przystosowania sejsmicznego dla opisanego wyżej układu ramowego.
PL
Artykuł przedstawia analizę stanu wytężenia żelbetowego komina pod obciążeniem sejsmicznym przy jednoczesnym uwzględnieniu jego wstępnego pochylenia związanego z wpływem górniczych deformacji podłoża. Komin obciążono ciężarem własnym i wiatrem zgodnie z lokalizacją oraz obciążeniem sejsmicznym. Przeprowadzono analizę wpływu pochylenia komina na jego odpowiedź dynamiczną przy wymuszeniu znanym akcelerogramem El Centro z 1940 r. Odpowiedź sejsmiczną oceniono, wykorzystując dodatkowo wybrane kryteria bezpiecznej pracy budowli sformułowane w Eurokodzie 8. Analizę uzupełniono wynikami w przypadku obciążenia zapisem silnego wstrząsu górniczego oraz projektowego modelu wstrząsu górniczego metodą spektrum odpowiedzi.
EN
The article presents capacity and dynamic response analysis of a reinforced concrete chimney under simultaneous seismic actionand initial leaning of the chimney. The chimney was subjected to dead load and local wind effects as well as the seismic excitations. An analysis of the effect of leaning of the chimney and its dynamic response was carried out using the familiar El Centro, 1940 accelerogram. The seismic response due simultaneous action of leaning and seismic excitations was analyzed using Eurocode 8 specific safety criteria. In addition response to strong mine tremor record and design response spectrum load of the mine quakes was computed and analyzed.
PL
Artykuł ilustruje problem związany z wpływem efektu P-Delta na wieżowe obiekty o jednym stopniu swobody, które zlokalizowane są na obszarach sejsmicznych. Przedstawiono parametryczną analizę wpływu efektu P-Delta na siły wewnętrzne i przemieszczenia prostego układu o jednym stopniu swobody poddanym oddziaływaniu sejsmicznemu.
EN
The article illustrates problems associated with P-Delta effect on tower objects with single degree of freedom located on seismic areas. Parametric analysis of internal forces and displacements of simple single degree of freedom system with P-Delta effect subjected to seismic loads was presented.
5
Content available remote Kształtowanie węzłów ram stalowych narażonych na oddziaływania sejsmiczne
EN
Seismic resistant steel structures are usually designed to allow for the dissipation of the seismic energy input in specially selected zones of structures. In moment resisting steel frames subjected to seismic actions, beam to column connections can play an important role, influencing the localization of dissipative zones. Designing of reinforced moment-resisting connections or reduced beam sections moment connections creates dissipative zones in the ends of the beams. Designing of semi-rigid, partial-strength joints permits to create of dissipative zones also in the connections. In this case the cyclic behaviour of beam-to-column connections is affected by the type of components engaged in the plastic range. The proper choice of the dissipative component and suitable detailing of the connection are key elements of seismic design.
EN
The paper presents a review of seismic structural interventions applied to historical masonry buildings, as they were developed and/or tested at the University of Padova. Safeguard of historical buildings from the seismic risk is a difficult task regarding first the prevention, and then the whole process from building assessment through design and execution of interventions. The adoption of the same classes of predictive models developed for new constructions can mislead about the real behaviour of the structures, and can bring to the choice of useless or even harmful interventions for their seismic protection as outlined in the Italian guidelines. The recent seismic events confirmed limits and consequences of some type of interventions, concurrently corroborated also by extensive experimental researches, but also the effectiveness of new methods based on the use of both traditional and innovative materials and techniques.
PL
Artykuł przedstawia przegląd antysejsmicznych interwencji konstrukcyjnych, odnoszących sił do historycznych budynków murowanych, jakie były opracowane i / lub testowane na Uniwersytecie w Padwie. Zabezpieczenie historycznych budynków przed zagrożeniem sejsmicznym jest trudnym zadaniem uwzględniającym najpierw zapobieganie,a następnie cały proces, od oceny budynku poprzez projektowanie i wykonanie interwencji. Adaptowanie tych samych kategorii modeli przewidujących,jakie opracowano dla nowych budynków, może być mylące, jeżli chodzi o prawdziwe zachowanie sił konstrukcji, i może doprowadzić do wyboru bezużytecznych lub nawet szkodliwych interwencji dla sejsmicznej ochrony budynków, jak nakreólono we włoskich zaleceniach. Niedawne wydarzenia sejsmiczne potwierdziły ograniczenia i konsekwencje niektórych typów interwencji, jednocześnie potwierdzone również przez obszerne badania doświadczalne,ale potwierdziły równieo skuteczność nowych metod, bazujących na zastosowaniu zarówno tradycyjnych,jak i nowatorskich materiałów i technik.
first rewind previous Strona / 1 next fast forward last