Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  odczynnik
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
For the first time, the impact of the composition of gossypol resin and IB-1 reagent, prepared in a 3:1 ratio and conventionally named HS-1, on the corrosion rate in hydrogen sulfide formation water has been investigated under laboratory conditions. Concentrations of 20, 40, 60, 80 mg/l of the new composition were used. During the experiments, a formation water sample taken from well No. 1082 of “Bibiheybatneft” OGPD, SOCAR, served as the electrochemical corrosion medium for the study. To conduct a comparative analysis, gossypol resin, IB-1 inhibitor, and HS-1 composition were used. Concentrations of 50, 100, 150, 200 mg/l of gossypol resin and 10, 15, 20, and 25 mg/l of IB-1 inhibitor were employed in the experiments. Numerous laboratory experiments revealed that the optimal consumption rate for the HS-1 inhibitor is 100 mg/l, for gossypol resin it is 200 mg/l, and for the IB-1 inhibitor it is 25 mg/l. These experiments were conducted under dynamic conditions over six hours. It was determined that the newly developed HS-1 composition offers superior protection in an aggressive medium containing hydrogen sulfide compared to its constituent components, gossypol resin, and IB-1 inhibitor. Specifically, as the concentration of gossypol resin in formation water increases from 50 to 200 mg/l, the corrosion protection effect ranges from 60–82%. When the concentration of IB-1 inhibitor varies between 10–25 mg/l in a hydrogen sulfide medium, the protection effect lies between 65-90%. In the aggressive medium of hydrogen sulfide formation water, increasing the concentration of the new HS-1 composition from 30–80 mg/l results in an enhancement of its electrochemical corrosion protection effect, ranging from 74–98%. Upon analyzing the results of numerous laboratory experiments, it was found that the optimal consumption rate of gossypol resin for corrosion protection in an aggressive medium with hydrogen sulfide is 200 mg/l, the consumption rate of IB-1 inhibitor is 25 mg/l, and for the HS-1 composition is 80 mg/l. The corrosion rates for gossypol resin in the concentrations of 50, 100, 150, 200 mg/l is 1.72, 1.38, 1.12, 0.78 g/m2  · h and retardation coefficient is 2.50, 3.10, 3.84, 5.51, respectively. Corrosion rate of IB-1 inhibitor concentration in the amount of 10, 15, 20, and 25 mg/l is 1.5, 1.12, 0.78, 0.43, and retardation coefficient is 2.86, 3.84, 5.51, 10.0, respectively. The corrosion rates for the new HS-1 composition at concentrations of 20, 40, 60, 80 mg/l is 1.12, 0.73, 0.34, 0.08, and the retardation coefficient is 3.84, 5.89, 12.64, 53.75, respectively. Comparing the corrosion rate values obtained for all three reagents with the corrosion rate for hydrogen sulphide formation water shows that new HS-1 composition has a higher effectiveness compared to its constituent components.
PL
Po raz pierwszy w warunkach laboratoryjnych zbadano wpływ składu żywicy gossypolowej i odczynnika IB-1, przygotowanej w stosunku 3:1 i umownie nazwanej HS-1, na szybkość korozji w wodzie złożowej zawierającej siarkowodór. Zastosowano stężenia 20, 40, 60, 80 mg/l nowego składu. Podczas eksperymentów jako elektrochemiczne medium korozyjne do badań posłużyła próbka wody złożowej pobrana z odwiertu nr 1082 "Bibiheybatneft" OGPD, SOCAR. W celu przeprowadzenia analizy porównawczej w doświadczeniach wykorzystano żywicę gossypolową, inhibitor IB-1 oraz komponent HS-1. Pobrano 50, 100, 150, 200 mg/l żywicy oraz 10, 15, 20 i 25 mg/l inhibitora IB-1. Liczne badania laboratoryjne wykazały, że optymalne zużycie inhibitora HS-1 wynosi 100 mg/l, żywicy gossypolowej 200 mg/l, a inhibitora IB-1 25 mg/l. Doświadczenia te prowadzono w warunkach dynamicznych przez sześć godzin. Stwierdzono, że nowo opracowana kompozycja HS-1 zapewnia lepszą ochronę w agresywnym środowisku zawierającym siarkowodór w porównaniu z jej składnikami, żywicą gossypolową i inhibitorem IB-1. Zatem gdy stężenie żywicy gossypolowej w wodzie złożowej wzrośnie o 50–200 mg/l, efekt ochrony przed korozją przyjmuje wartość w przedziale 60–82%. Gdy stężenie inhibitora IB-1 waha się w granicach 10–25 mg/l w środowisku siarkowodorowym, efekt ochronny wynosi 65–90%. W agresywnym środowisku wód złożowych zawierających siarkowodór zwiększenie stężenia nowej mieszaniny HS-1 w zakresie 30–80 mg/l powoduje wzrost jej elektrochemicznego efektu antykorozyjnego w granicach 74–98%. Analizując wyniki licznych eksperymentów laboratoryjnych stwierdzono, że optymalne zużycie żywicy gossypolowej do ochrony przed korozją w agresywnym środowisku z siarkowodorem wynosi 200 mg/l, zużycie inhibitora IB-1 25 mg/l, a stopień zużycia kompozycji HS-1 80 mg/l. Szybkość korozji żywicy gossypolowej w stężeniach 50, 100, 150, 200 mg/l wynosi 1,72; 1,38; 1,12; 0,78 g/m2  ·h, a współczynnik opóźnienia wynosi odpowiednio 2,50; 3,10; 3,84; 5,51. Szybkość korozji przy stężeniu inhibitora IB-1 w ilościach 10, 15, 20 i 25 mg/l wynosi 1,5; 1,12; 0,78; 0,43, a współczynnik opóźnienia wynosi odpowiednio 2,86, 3,84, 5,51, 10,0. Szybkość korozji nowego składu HS-1 w stężeniach 20, 40, 60, 80 mg/l wynosi 1,12; 0,73; 0,34; 0,08, a współczynnik opóźnienia wynosi odpowiednio 3,84; 5,89; 12,64; 53,75. Porównanie wartości szybkości korozji uzyskanych dla wszystkich trzech odczynników z szybkością korozji w wodzie złożowej zawierającej siarkowodór wskazuje, że nowa kompozycja HS-1 ma wyższą skuteczność w porównaniu do jej poszczególnych składników.
EN
The corrosion protection effect of the new S-1 reagent in media with the pH values of 2.0, 4.0, 6.0, as well as carbon dioxide and hydrogen sulfide added separately and combined to the mentioned media, was first tested under laboratory conditions. The protective effect of reagent S-1 was weak in the corrosion medium without hydrogen sulfide and carbon dioxide. However, as the acidity of the medium and the concentration of the reagent increases, the corrosion protection efficiency of the inhibitor also increases. The highest effect is observed at pH = 2.0 and reagent concentration of 30 mg/l. The corrosion protection effect of the reagent reaches 97% under these conditions. In the media with pH = 4.0 and pH = 6.0 without carbon dioxide and hydrogen sulfide, the protective effect of the inhibitor at the optimal concentration of 30 mg/l is 66% and 64%, respectively. In the medium with added carbon dioxide, the protective effect of inhibitor S-1 decreases at pH = 2.0 and, on the contrary, increases at the values of pH = 4.0 and pH = 6.0. Also, as the pressure of carbon dioxide in the medium increases, the protective effect of inhibitor S-1 increases. When hydrogen sulfide is added to the medium, it causes an increase in the corrosion rate and the protection efficiency of inhibitor S-1. However, in the medium without inhibitor, the increase of hydrogen sulfide concentration only up to CH2S = 400 mg/l is accompanied by an increase in the corrosion rate at all values of pH. The addition of 1000 mg/l of hydrogen sulfide to the corrosion medium leads to the decrease in the corrosion rate in the medium without inhibitors and a slight decrease in the protective effect at the concentration of the inhibitor Cinh = 10 mg/l. As the concentration of inhibitor S-1 increases in the medium with the addition of carbon dioxide and hydrogen, its corrosion protection effect also increases. In the range of Cinh = 10–30 mg/l, when PCO2 = 0.5 atm and CH2S = 200 mg/l, the protective effect is estimated at 38–99%, and when CH2S = 1000 mg/l, it is estimated at 17–79%. At PCO2 = 1.0 atm, the value of protective effect is 22–95% and 14–76%, and finally at PCO2 = 2.0 atm, the value of the corrosion protection effect of inhibitor S-1 is estimated at 44–92% and 15–75%, respectively. The coexistence of carbon dioxide and hydrogen sulfide in an aggressive medium leads to an increase in the protective effect of inhibitor S-1 compared to the medium containing only carbon dioxide, and reduces it in comparison to the medium with hydrogen sulfide. An increase in carbon dioxide pressure in the presence of hydrogen sulfide causes a decrease in the protective effect of inhibitor S-1. The protective effect of inhibitor S-1 is lower in the medium with hydrogen sulfide concentration of 1000 mg/l compared to a concentration of 200 mg/l. This case is also observed in the carbon dioxide free medium.
PL
Działanie antykorozyjne nowego odczynnika S-1 w agresywnych mediach o pH 2,0; 4,0; 6,0, a także dwutlenku węgla i siarkowodoru dodawanych osobno lub łącznie do tych mediów, zostało najpierw zbadane w warunkach laboratoryjnych. Działanie ochronne odczynnika S-1 było słabe w środowisku korozyjnym bez siarkowodoru i dwutlenku węgla. Jednak wraz ze wzrostem kwasowości medium i stężenia odczynnika wzrasta również skuteczność inhibitora w ochronie przed korozją. Najlepsze działanie antykorozyjne odnotowano przy wartości pH = 2,0 i stężeniu odczynnika 30 mg/l. Skuteczność ochronna odczynnika wynosi wówczas 97%. W medium o pH = 4,0 i pH = 6,0 bez dwutlenku węgla i siarkowodoru skuteczność ochronna inhibitora przy optymalnym stężeniu 30 mg/l wynosi odpowiednio 66 i 64%. W medium z dodatkiem dwutlenku węgla działanie ochronne inhibitora S-1 maleje przy wartości pH = 2,0 i odwrotnie wzrasta przy wartościach pH = 4,0 i pH = 6,0. Ponadto, wraz ze wzrostem ciśnienia dwutlenku węgla w środowisku wzrasta skuteczność ochronna inhibitora S-1. Dodanie siarkowodoru do medium powoduje wzrost tempa korozji i skuteczności ochronnej inhibitora S-1. Jednak w medium bez inhibitora wzrostowi stężenia siarkowodoru nawet do tak niskiej wartości jak CH2S = 400 mg/l towarzyszy wzrost tempa korozji przy wszystkich wartościach pH. Dodanie 1000 mg/l siarkowodoru do medium korozyjnego prowadzi do zmniejszenia tempa korozji w medium bez inhibitorów i nieznacznego zmniejszenia działania ochronnego przy stężeniu inhibitora Cinh = 10 mg/l. Wraz ze wzrostem stężenia inhibitora S-1 w medium z dodatkiem dwutlenku węgla i siarkowodoru, zwiększa się również jego działanie antykorozyjne. W zakresie Cinh = 10–30 mg/l, gdy PCO2 = 0,5 atm i CH2S = 200 mg/l, skuteczność ochronną szacuje się na 38–99%, natomiast przy CH2S = 1000 mg/l na 17–79%. Dla PCO2 = 1,0 atm skuteczność ochronna wynosi od 22–95% do 14–76%, a przy PCO2 = 2,0 atm skuteczność antykorozyjną inhibitora S-1 szacuje się odpowiednio na 44–92% i 15–75%. Jednoczesne występowanie dwutlenku węgla i siarkowodoru w agresywnym medium zwiększa skuteczność ochronną inhibitora S-1 w stosunku do medium zawierającego tylko dwutlenek węgla i zmniejsza ją w porównaniu do medium z siarkowodorem. Wzrost ciśnienia dwutlenku węgla w obecności siarkowodoru powoduje zmniejszenie skuteczności ochronnej inhibitora S-1. Ulega ona także zmniejszeniu w środowisku o stężeniu siarkowodoru 1000 mg/l w porównaniu do stężenia 200 mg/l. Ten przypadek obserwuje się również w środowisku bez dodatku dwutlenku węgla.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.