Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 20

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  odbiornik
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study presents a modified algorithm to determine the accuracy of GPS positioning in aerial navigation. To achieve this, a mixed model with measurement weights was used to determine the resultant value of accuracy of aerial vehicle positioning. The measurement weights were calculated as a function of the number of GPS tracking satellites. The calculations were performed on actual GPS measurement data recorded by two onboard GNSS receivers installed onboard a Cessna 172 aircraft. The flight test was conducted around the military airport in Dęblin. The conducted analyses demonstrated that the developed algorithm improved the accuracy of GPS positioning from 62 to 91% for horizontal coordinates and between 16-83% for the vertical component of the aerial vehicle position in the BLh ellipsoidal frame. The obtained test results show that the developed method improves the accuracy of aircraft position and could be applied in aerial navigation.
PL
Odbiornikami energii elektrycznej w sieciach niskiego napięcia są głównie odbiorniki jednofazowe, które po zgrupowaniu w obrębie danego odbiorcy tworzą obciążenie trójfazowe. Taki zastępczy odbiornik trójfazowy pracuje w układzie czteroprzewodowym. Dodatkowo, w warunkach rzeczywistych, napięcie zasilające posiada pewną asymetrię amplitudową oraz fazową. Asymetria napięcia i niezrównoważenie odbiornika to zagadnienia, które nie zostały uwzględnione jednocześnie w równaniu mocy w układach czteroprzewodowych. Niniejszy artykuł eliminuje ograniczenie elektrotechniki z tego zakresu poprzez wyprowadzenie równania mocy odbiorników trójfazowych zasilanych napięciem niesymetrycznym.
EN
Electricity receivers in low-voltage networks are mainly single-phase loads, which, when grouped within a given consumer, create a three-phase load. Such a replacement three-phase load works in a four-wire system. Besides, under real conditions, the supply voltage has some amplitude and phase asymmetry. Voltage unbalances, load's imbalances are issues that not simultaneously included in the power equation in four-wire systems. This article eliminates the limitations of electrical engineering in this area by deriving the power equation for three-phase loads supplied with unbalanced voltage.
EN
Electricity receivers in low-voltage networks are mainly single-phase loads, which, when grouped within a given consumer, create a three-phase load. Such a replacement three-phase load works in a four-wire system. Besides, under real conditions, the supply voltage has some amplitude and phase asymmetry. Voltage unbalances, load's imbalances are issues that not simultaneously included in the power equation in four-wire systems. This article eliminates the limitations of electrical engineering in this area by deriving the power equation for three-phase loads supplied with unbalanced voltage.
PL
Odbiornikami energii elektrycznej w sieciach niskiego napięcia są głównie odbiorniki jednofazowe, które po zgrupowaniu w obrębie danego odbiorcy tworzą obciążenie trójfazowe. Taki zastępczy odbiornik trójfazowy pracuje w układzie czteroprzewodowym. Dodatkowo, w warunkach rzeczywistych, napięcie zasilające posiada pewną asymetrię amplitudową oraz fazową. Asymetria napięcia i niezrównoważenie odbiornika to zagadnienia, które nie zostały uwzględnione jednocześnie w równaniu mocy w układach czteroprzewodowych. Niniejszy artykuł eliminuje ograniczenie elektrotechniki z tego zakresu poprzez wyprowadzenie równania mocy odbiorników trójfazowych zasilanych napięciem niesymetrycznym.
4
Content available Selected Issues of the Quality of Operation of GSM-R
EN
The article presents selected issues related to GSM-R system installed by PKP for the needs of ERTMS past-related control system, as well as the replacement of VHF analogue radio system used so far in the Polish railway system. Particular attention was given to the problems of: transition period, i.e. transition from the VHF system to the GSM-R system; proper installation of radio antennas on traction vehicles during the transition period; interfering impact of public narrowband and broadband mobile systems on the GSM-R system.
PL
W artykule przedstawiono wybrane problemy związane z instalowanym przez PKP systemem GSM-R dla potrzeb przeszłościowego systemu sterowania ERTMS a także zastąpienia radiowego systemu analogowego VHF stosowanego do tej pory w polskim kolejnictwie. Szczególną uwagę poświęcono problemom: okresu przejściowego tj. przejścia z systemu VHF do systemu GSM-R, odpowiedniej instalacji anten radiowych na pojazdach trakcyjnych w okresie przejściowym, zakłócającego wpływu publicznych systemów komórkowych wąsko- i szerokopasmowych na system GSM-R.
PL
Artykuł zawiera ocenę wpływu ścieków, odpływających z oczyszczalni w Szczawnicy przed i po modernizacji obiektu, na skład fizykochemiczny oraz jakość wód ich odbiornika – rzeki Dunajec. Pracę wykonano na podstawie analizy pobranych próbek ścieków surowych i oczyszczonych oraz wód odbiornika. Punkty poboru wody z Dunajca znajdowały się odpowiednio powyżej i poniżej punktu zrzutu ścieków z OŚ. Zakres oznaczanych wskaźników zanieczyszczeń obejmował 14 parametrów fizykochemicznych oraz dwa wskaźniki bakteriologiczne. Na podstawie wykonanych badań stwierdzono, że OŚ w Szczawnicy po jej modernizacji w 2016 r. funkcjonowała prawidłowo. Oczyszczone ścieki na niej spełniały wymogi pozwolenia wodnoprawnego, co przekładało się bezpośrednio na skuteczną ochronę przed zanieczyszczeniem wód odbiornika. Potwierdziły to wyniki zastosowanego testu Kruskala-Wallisa, które wykazały statystycznie istotne różnice pomiędzy medianami wartości stężeń azotu ogólnego przed i po modernizacji obiektu. W przypadku pozostałych analizowanych wskaźników zanieczyszczeń (zawiesiny ogólnej, BZT5, ChZTCr, fosforu ogólnego) nie wykazano statystycznie istotnych różnic pomiędzy medianami. Ponadto stwierdzono, że w obydwu badanych przekrojach skład fizykochemiczny wód Dunajca był do siebie zbliżony. Ścieki oczyszczone, odprowadzane z oczyszczalni w Szczawnicy do rzeki Dunajec nie przyczyniły się do pogorszenia jakości jego wód w przypadku wskaźników fizykochemicznych. Na podstawie klasyfikacji tych elementów określono, że w analizowanym okresie badań wody Dunajca w przekroju bezpośrednio powyżej i poniżej OŚ spełniają wymogi dla kategorii A1 wód przeznaczonych na zaopatrzenie ludności (woda bardzo dobrej jakości). W przypadku klasyfikacji mikrobiologicznej, dokonanej na podstawie ilości bakterii grupy coli i Escherichia coli, Dunajec zakwalifikowano do IV i V klasy (woda niezadowalającej i złej jakości), co tym samym wyklucza jego wody jako przeznaczone do spożycia oraz jako miejsce potencjalnych kąpielisk.
EN
This article includes an assessment pertaining to the impact of sewage discharged from the sewage treatment plant in Szczawnica before and after the modernization of the facility, the physicochemical composition and the quality of the water of their receiver, i.e. Dunajec River. The work was carried out on the basis of the analysis of samples taken from the raw and purified sewage and receiver waters. The Dunajec water intake was above and below the point of sewer discharge from the wastewater treatment plant (WWTP). The range of contaminated indicators included 14 physicochemical parameters and two bacteriological indicators. On the basis of the research conducted, it was stated that the Szczawnica Forest Enterprise functioned correctly after its modernization in 2016. The purified sewage on it complies with the requirements of a water permit, which translates directly into effective protection against the pollution of receiver waters. This was confirmed by the results of the Kruskal-Wallis test that showed statistically significant differences between the median values of overall nitrogen concentrations before and after the refurbishment of the facility. For the remaining pollutant indices (total suspensions, BOD5, CODCr, total phosphorus), no statistically significant differences were found between the medians. In addition, it was found that the physicochemical composition of Dunajec waters was similar in both examined sections. The purified efflu ent discharged from the Szczawnica treatment plant to the Dunajec River did not contribute to deterioration of its water quality in the case of physicochemical indicators. On the basis of on the classification of these elements, it was determined that in the analyzed period, the Dunajec water in the section directly above and below the WWTP meets the requirements for category A1 of waters intended for the supply of the population (very good quality water). In the case of microbiological classification based on the number of bacteria of the coli group and Escherichia coli, Dunajec was classified as IV and V class (unsatisfactory and poor quality water), thus excluding its water for consumption and as a potential bathing place.
PL
W artykule opisano system do pomiaru parametrów upodatnienia prowadników i obudowy szybowej realizowany w ramach projektu celowego MNiSzW–GIG–UNIKOL Spółka z o.o. System składa się z przetworników pomiaru upodatnienia zbrojenia szybowego, czujnika kontroli upodatnienia obmurza, odbiornika transmisji i konwertera f/U, linii kablowej zasilania i transmisji danych, zasilacza iskrobezpiecznego, rejestratora cyfrowego. Idea systemu wykonanego w wersji iskrobezpiecznej zakłada automatyczny pomiar szerokości dylatacji na wszystkich prowadnikach danego poziomu oraz względnego przemieszczenia/deformacji między obmurzem nad i pod upodatnieniem.
EN
The article describes a system for measuring of elasticity parameters of guides and shaft's lining realized within the target project by Ministry of Science and Education-CMI-Unikol Ltd Co. The system consists of transducers of elasticity measurement of shaft's reinforcement, a sensor of elasticity monitoring of the brickwork, transmission receiver and f/U converter f/U, a power and data transmission cable line, intrinsically safe power supply, a digital recorder. The idea of the system, made in an intrinsically safe mode, assumes automatic measurement of the width of expansion at all guides of a given level and the relative displacement / deformation between the brickwork above and below yielding.
PL
Zwiększenie efektywności oczyszczania ścieków uwydatnia rolę przelewów burzowych w pogarszaniu jakości wód odbiornika, albowiem ładunki zanieczyszczeń przez nie odprowadzane, mają coraz większy udział we wszystkich ładunkach zrzucanych do odbiornika. W niniejszym artykule zawarto wyniki analiz jakości ścieków emitowanych do odbiornika z trzech badanych przelewów burzowych kanalizacji ogólnospławnej miasta Łodzi. Wykazały one dużą zmienność stężenia zanieczyszczeń kierowanych do odbiornika podczas opadów. Przedstawiono również możliwy wpływ nieoczyszczonych ścieków emitowanych tą drogą na odbiornik. Oprócz zanieczyszczenia odbiornika, przede wszystkim substancjami organicznymi i biogennymi, należy zwrócić szczególną uwagę na jego skażenie mikrobiologiczne, niebezpieczne dla ludzi, wykorzystujących rzeki jak miejsce rekreacji oraz dla zwierząt, korzystających z odbiorników wodnych jako źródła wody pitnej.
EN
Increased efficiency of wastewater treatment highlights the role of combined sewer overflows in deterioration the quality of water receiver because pollutant loads discharged by them have a growing share in entire load discharged into a receiver. The article contains the results of the wastewater quality analyzes emitted into the receiver from the three studied combined sewer overflows of the city of Lodz. The results demonstrated a large variations in the pollutant concentration directed to the receiver during rain events. The possible impact of untreated wastewater emitted to the receiver is also presented. Apart from the pollution of the receiver, mainly by organic and nutrient substances, the microbiological contamination which is dangerous for people using the river as a recreation area and for animals that use a water receiver as a source of drinking water, should be taken into particular attention.
PL
Artykuł zawiera analizę i ocenę wpływu ścieków oczyszczonych w oczyszczalni w Myślenicach w latach 2008 - 2011, na skład fizyczno-chemiczny oraz jakość wód ich odbiornika - rzeki Raby. Pracę wykonano na podstawie zebranych oraz statystycznie opracowanych wyników badań, obejmujących ilość i skład ścieków oczyszczonych, odprowadzanych do Raby, a także skład wód odbiornika w przekrojach Stróże i Osieczany, znajdujących się odpowiednio powyżej i poniżej punktu zrzutu ścieków oczyszczonych. Zakres wskaźników zanieczyszczeń oznaczanych w ściekach i wodzie obejmował: zawiesinę ogólną, BZT5 , ChZTCr, fosfor ogólny oraz azot ogólny. Na podstawie wykonanych badań stwierdzono, że oczyszczalnia ścieków w Myślenicach, w latach 2008 - 2011, funkcjonowała prawidłowo, ponieważ oczyszczone na niej ścieki, spełniały wymogi pozwolenia wodno-prawnego, co przekładało się bezpośrednio na skuteczną ochronę przed zanieczyszczeniem wód ich odbiornika. Ponadto stwierdzono, że w obu badanych przekrojach skład fizyczno-chemiczny wód Raby był do siebie zbliżony. Potwierdziły to wyniki zastosowanego testu U Mann'a-Whitney'a, które nie wykazały statystycznie istotnych różnic pomiędzy średnimi wartościami stężeń analizowanych wskaźników zanieczyszczeń. Ścieki oczyszczone, odprowadzane z oczyszczalni w Myślenicach do rzeki Raby nie przyczyniają się do pogorszenia jakości jej wód.
EN
The article contains analysis and evaluation of the impact of clean sewage on sewage treatment plant in Myślenice, in the period 2008 - 201,1 on the physico-chemical composition and water quality of the receiver - river Raba. The analysis conducted based on collected and statistical research: amount and composition of clean sewage and composition of the water receiver in cross-section: Stróże (above of inflow clean sewage) and Osieczany (below of inflow clean sewage). The following pollution index were tested: total suspended solids, BOD5, CODCr, total nitrogen and total phosphorus. Based on obtained results its concluded that in period 2008 - 2011 sewage treatment plant was working properly, what explain quality of clean sewage. What reflected in directly protection of receiver water against pollution. Moreover, based on the results of U Mann Whitney test, concluded that in the both cross-section, composition of the water of Raba river was similar, what explain the results of this test, which didn't show statistically significant differences between average values of concentrations analyzed indicators of pollutions. Based on obtained results its concluded that sewage treatment plant in Myślenice doesn't negatively impact on quality of the water receiver -Raba river.
PL
Większość przydomowych oczyszczalni odprowadza ścieki do odbiornika w postaci gruntu, najczęściej za pomocą urządzeń infiltracyjnych. Celem badań było porównanie wybranych metod określania wodoprzepuszczalności gruntu pod kątem oceny jego przydatności jako odbiornika ścieków. Współczynniki filtracji określono w badaniach terenowych (test perkolacyjny), laboratoryjnych (pomiar w aparacie de Wit’a) oraz metodą obliczeniową (na podstawie wyników analizy sitowej). Analizą objęto 7 potencjalnych lokalizacji przydomowych oczyszczalni. Na podstawie krzywych uziarnienia badane grunty zostały sklasyfikowane jako: piasek słabogliniasty, piasek gliniasty i glina piaszczysta. Najwyższe wartości współczynników filtracji badanych gruntów uzyskano w badaniach terenowych, a najniższe metodami obliczeniowymi. Obliczone obciążenia hydrauliczne badanych gruntów we wszystkich przypadkach są znacznie niższe niż wartość LTAR. Przyczyną może być fakt, że wykorzystana do obliczeń zależność była opracowana dla ścieków oczyszczonych mechanicznie i uwzględniała kolmatację systemu odpływającymi z osadnika zawiesinami. W przypadku ścieków biologicznie oczyszczonych rozprowadzanych w badanych gruntach drobnoziarnistych, powierzchnia infiltracji obliczona na podstawie testu perkolacyjnego zapewni bezpieczne odprowadzanie ścieków przez wiele lat eksploatacji przydomowej oczyszczalni.
EN
Majority of on-site wastewater treatment plants discharge effluents to the soil by infiltration systems. The aim of the study was to compare choosen methods of determinantion of soil permeability for its use as a receiver for domestic wastewater. Filtration coefficiens were determined in on-site percolation test, laboratory test (de Wit aparatus) and calculation method (base on grain size analysis). Soils from seven different potential locations of on-site wastewater treatment systems were tested. Soils were characterised as sandy loams and loamy sands. The highest values of filtration coefficients were obtained from percolation tests and the lowest from the calculation method. Calculated hydraulic loads in all cases are lower than values of LTAR (Long-Term Acceptance Rate). The possible reason is that used equation was developed for simple septic systems and includes clogging of soil by solids from pre-treated wastewater. In case of biologically treated wastewater distributed in tested fine-grained soils, infiltration surface determined base on the percolation test, will ensure safe disposal of wastewater for long time of operation of on-site wastewater treatment system.
PL
W artykule zaprezentowano układ scalony pozwalający na bezinwazyjny pomiar nasycenia krwi tlenem, oparty na zjawisku różnego stopnia absorbcji światła w zależności od długości fali świetlnej oraz stopnia natlenienia krwi (oksymetria optyczna). Powstał on jako część systemu monitorowania podstawowych parametrów życiowych człowieka. Zawiera analogowe bloki nadajnika i odbiornika oraz cyfrowy blok odpowiedzialny za kontrolę pracy układu, wstępną obróbkę sygnału oraz komunikacje z innymi elementami systemu za pośrednictwem interfejsu SPI. Układ został wyprodukowany w technologii UMC 130 nm.
EN
The integrated chip allowing non-invasive measurement of blood oxygen saturation basing on the difference in the degree of light absorption depending on the wavelength and the degree of oxygenation of blood (puls oximetry) is presented. It has been developed as a part of the system for monitoring of the human vital signs. The circuit contains an analog transmitter block, an analog receiver block and a digital block for controling the operation of analog blocks, pre-processing the signal from the receiver unit and communication with other system components through the SPI interface. The chip has been fabricated in UMC 130 nm technology.
PL
W artykule przedstawiono opracowanie protokołu SMN (ang. Synchronized Measurement Network) oraz uwarunkowania, wynikające ze specyfiki wybranych radiowych układów nadawczo-odbiorczych. Prezentowane rozwiązanie należy do bezprzewodowych sieci sensorowych (ang. WSN – Wireless Sensor Networks). Protokół SMN jest przeznaczony do synchronizowanej, bezprzewodowej realizacji pomiarów rozproszonych. Omawiana sieć zapewnia możliwość energooszczędnej pracy jej węzłów oraz spełnia warunki bezpieczeństwa transmisji.
EN
This paper presents the development of SMN protocol (Synchronized Measurement Network) and conditions resulting from the specificity of selected radio transceiver systems. This solution is a wireless sensor network (WSN – Wireless Sensor Networks). SMN protocol is designed for execution of synchronized, distributed wireless measurement. The presented network provides the possibility of energy-saving work of its nodes and meets the security conditions of transmission.
PL
Większość odbiorników prądu przemiennego pobiera moc i energię czynną, a także moc i energię bierną pulsującą między układem zasilającym a odbiornikiem. Oczywistym jest, że moc czynna jest w całości przetwarzana na pracę urządzenia oraz straty cieplne. Natomiast moc bierna nie wykonuje żadnej pracy, wpływa natomiast, a nawet warunkuje poprawne działanie odbiorników.
14
Content available remote Wejściowy stopień wzmacniający odbiornika mikrofalowego na pasmo X
PL
Artykuł obejmuje treści i zagadnienia związane ze stopniem wejściowym odbiornika mikrofalowego na pasmo X. Przedstawiono w nim zagadnienia związane z układami współczesnych odbiorników radioelektronicznych. W artykule przedstawiono proces projektowania, symulacji, wykonania i badania podstawowych układów mikrofalowych wchodzących w skład stopnia wejściowego odbiornika, takich jak niskoszumne wzmacniacze mikrofalowe oraz pasmowo-przepustowe filtry mikrofalowe pracujące w paśmie X. Na zakończenie dokonano pomiarów tak zaprojektowanych i wykonanych układów.
EN
The problems and subjects of the input stage front–end microwave receiver for X-band have been discussed in the paper. The subjects comprised with modern radioelectronic receivers for X-band have been presented. The successive processes: designing, simulation, practical realization and investigation have been discussed. This processes are similar for all components of the front-end receiver, such as: low-noise microwave amplifiers and passband microwave filter, working in X-band. At the end, measured characteristics of the designed and practically realized circuits have been presented.
PL
W niniejszym artykule zaproponowano kompletną architekturę radia programowalnego. Omówiono architekturę opracowanego systemu wraz z wymaganiami stawianymi każdemu z bloków przetwarzających sygnał. Przedstawiono prototypową implementacje, jej specyfikację, uwagi projektowe oraz aplikację kliencką
EN
In this paper, a complete architecture of the software defined radio receiver is proposed. First, a precise definition and the discussion of the problem is given. Next, an outline of the system topology is proposed, together with the requirements for each component of the system. Finally, a custom implementation is presented, including specifications, design considerations, and client application.
PL
W niniejszej pracy przedstawiona jest idea metody kasowania echa silnego sygnału pochodzącego z nadajnika, który współdzieli medium transmisyjne (np. antenę) z odbiornikiem. Taka konfiguracja może prowadzić do stałego nasycenia odbiornika, co uniemożliwia zastosowanie metod kasowania echa opartych na cyfrowym przetwarzaniu sygnału lub aktywnej filtracji. Opisana metoda polega na wprowadzeniu kopii niepożądanego sygnału do obwodu zasilania odbiornika i teoretycznie ona pozwala uniknąć nasycenia odbiornika przy dowolnie dużej mocy sygnału nadawanego. W pracy przedstawione są wyniki pierwszych pomiarów potwierdzających działanie tej metody.
EN
In this paper, there is presented a method of cancellation of echo of a strong signal coming from a transmitter sharing a common transmission medium (e.g. an antenna) with a receiver. In this configuration, a constant saturation of the receiver may occur, making impossible application of echo cancellation method based on digital signal processing or active filtration. The idea of the discussed method is to inject a copy of the unwanted signal into the receiver's power supply circuit and theoretically it allows to avoid the receiver's saturation at arbitrarily high power of the transmitted signal. First results of measurements supporting the proposed method are presented.
17
Content available remote Bezprzewodowy system detekcji magnetycznej
PL
System Bezprzewodowej Detekcji Pojazdów wykorzystuje zamontowane pod powierzchnią ziemi sensory magnetyczne do wykrywania obecności pojazdów. Sensory przekazują informację o pojazdach drogą radiową do odbiornika, który z kolei przesyła tą informację do sterownika ruchu drogowego. Jeżeli sensory znajdują się poza zasięgiem odbiornika, stosuje się wzmacniacz, który będzie pośredniczył w przekazywaniu informacji od sensora. System Detekcji Magnetycznej jest alternatywą dla powszechnie stosowanych innych rodzajów detekcji takich jak pętle indukcyjne lub Wideodetekcja.
EN
Wireless Magnetic Detection System uses the pavement-mounted magnetic sensors to detect the presence and the movement of vehicles. The magneto-resistive sensors are wireless, transmitting their detection data in real-time via low-power radio technology to a nearby Access Point (or Repeater) that then relays the data to one or more local or remote traffic management controllers and systems. Wireless Magnetic Detection System can be used as an alternative for the cameras or the inductive loops.
PL
Rozpatrzono zależność sprawności sprzężenia pomiędzy światłowodem o skokowym profilu refrakcyjnym i odbiornikiem w funkcji rozmiarów i położenia odbiornika. Stwierdzono, że w przypadku osiowego położenia światłowodu i odbiornika mniejsze zmiany sprawności uzyskuje się dla światłowodów o mniejszej aperturze numerycznej. Jeżeli światłowód i odbiornik nie są położone osiowo sprawność sprzężenia zmienia się tym wolnej, im większa jest apertura numeryczna światłowodu.
EN
The dependence of the dimensions and localization of receiver on the efficiency of coupling between step-index fiber and receiver was considered. When the fiber and the receiver are placed axially, the efficiency of coupling decreases more slowly for small numerical aperture of the fiber. When they are not placed axially it decreases faster for small fiber's numerical aperture.
PL
Globalny system pozycjonowania (GPS) wzbudza znaczne zainteresowanie rolnictwa, otwierając drogę do realizacji zasad tzw. rolnictwa precyzyjnego. Potrzebna jest zatem dobra znajomość możliwości i ograniczeń odbiorników GPS oferowanych przez wielu producentów. W artykule omówiono wyniki badań publikowane w literaturze, dotyczące kilku stosowanych w rolnictwie odbiorników GPS, oraz wyniki badań własnych wybranego odbiornika, który ze względu na stosunkowo dobre parametry techniczne i niską cenę ma szansę znaleźć szersze zastosowanie w polskim rolnictwie. Określono dokładność pomiaru pozycji geograficznej maszyny tym odbiornikiem w warunkach statycznych i dynamicznych oraz ewentualne zakresy jego zastosowania.
EN
Global positioning system (GPS) involves a great notice in agriculture, opening the road to realisation of the precision agriculture. There is a great need to know all the possibilities and boundaries of the systems offered on the market. In this article the short overview of the results of field tests of some commonly applied in agriculture GPS receivers is described, as well as the own research results of stationary and dynamic tests of the selected receiver, which taking into account its good technical parameters and low price has the chance to be widely applied in Polish agriculture.
20
Content available remote Experimental GNSS receiver
EN
At the Czech Technical University in Prague the Experimental GNSS Receiver based on Software Defined Radio Architecture has been developed. The receiver is determined for research and development of new GNSS signal processing algorithms including massive parallel processing for navigation in urban area with low quality signal coverage and for the study of new forms of the GNSS signals during the early phase of the GALILEO mission. As a first step the ability of weak signal processing in indoor environment was tested.
PL
Na Politechnice Czeskiej w Pradze opracowano Doświadczalny Odbiornik GNSS oparty na Zdefiniowanej Komputerowo Architekturze Radiowej. Odbiornik jest przeznaczony do badania i opracowania nowych algorytmów przetwarzania sygnałów GNSS, włącznie z masowym przetwarzaniem równoległym do nawigacji w obszarach miejskich, w zasięgu sygnału niskiej jakości oraz do opracowania nowych form sygnałów GNSS w czasie wczesnych etapów prac nad GALILEO. Jako pierwszy krok przetestowano możliwość przetwarzania słabego sygnału w zamkniętych pomieszczeniach.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.