Automotive electrical connectors are the essential components of a wiring harness. They are typically made of copper, which has excellent electrical conductivity. Due to the limited corrosion resistance of pure copper, connectors are often coated with other metals. In this paper, the qualities of coatings made of gold and tin are investigated and compared. The samples were examined by a metallographic microscope and scanning electron microscope (SEM). The examination revealed uneven thickness, delamination of the coatings, and issues with the preparation of the core material for coating. Numerous burrs and irregularities were observed. Selected samples were examined in salt solution to test their corrosion resistance. Even though gold is a noble metal and its electrochemical potential is higher, the tin coating was more resistant to corrosion.
PL
Praca przedstawia koncepcję ochrony elektrochemicznej przed korozją rurociągów i kabli napięciowymi falami wędrownymi wytworzonymi w chronionej konstrukcji przez impulsowe źródło napięcia. Pojedynczy impuls napięciowy przemieszcza się w rurociągu lub opancerzeniu kabla w postaci napięciowej fali wędrownej, która po dotarciu do jego nieuziemionego końca, ulega odbiciu, nie zmieniając swojej biegunowości. Odbita część fali napięciowej dodaje się do części fali przychodzącej zwiększając tym samym polaryzację końcowej części chronionej konstrukcji. W ten sposób polaryzacja konstrukcji impulsowym źródłem napięcia stwarza możliwość zwiększenia długości odcinka chronionej konstrukcji, który może być skutecznie chroniony przed korozją przy zasilaniu ochrony z jednego źródła.
EN
The work presents a conception of electrochemical cathodic protection of a pipeline by means of voltage travelling waves generated by a source of repetitive voltage pulses. A single voltage pulse moves in the form of a voltage travelling wave that reaching pipeline end reflects backward without changing its polarity. The reflected part of the voltage wave superposes with the incoming one, strengthening, at the same time, polarization of the pipeline end. The above conception was verified by polarization of a steel pipeline at first with constant voltage and then with repetitive voltage pulses. Hence, pipeline polarization with repetitive voltage pulses enables increasing of the length of pipeline section that might be subject to effective electrochemical protection supplied from a single source.
EN
In the work, the results of testing the actuator piston rod that corroded in the operating conditions are presented. It was found that the direct cause of the corrosion were local damages of the Cr/Ni dual-layer coating. In locations of cracking, a brittle chromium coating and deterioration was observed with the character of the sub-coating corrosion intensified by the influence of chloride ions. In consequence, it led to losing its adhesion, and locally exposed the nickel coating, which is less resistant to mechanical impact. The corrosive or mechanical damages of the nickel sub-layer led to uncovering the steel substrate-constituting anode, which was the direct cause of the appearance of the corrosion pits observed macroscopically.
PL
W pracy przedstawiono wyniki badań tłoczyska siłownika hydraulicznego, które uległo korozji w warunkach eksploatacyjnych. Stwierdzono, że bezpośrednią przyczyną korozji było występowanie lokalnych uszkodzeń dwuwarstwowej powłoki Cr/Ni. W miejscach spękań kruchej warstwy chromowej obserwowano niszczenie o charakterze korozji podpowłokowej, intensyfikowanej oddziaływaniem jonów chlorkowych. W konsekwencji doprowadziło to do utraty jej adhezji i miejscowego odsłonięcia mniej odpornej na oddziaływania mechaniczne powłoki niklowej. Uszkodzenia korozyjne lub mechaniczne podwarstwy niklu prowadziły do odsłonięcia podłoża stalowego stanowiącego anodę, co było bezpośrednią przyczyną powstania obserwowanych makroskopowo wżerów korozyjnych.
EN
The potentiodynamic polarization test and slow strain rate tensile tests of X80 pipeline steel were performed in 0.5M Na2CO3-1M NaHCO3 solution to study the electrochemical and stress corrosion cracking properties. The results of potentiodynamic polarization test show that there is an obvious stable passive region, about from 0v to 0.8V (SCE), indicating that anodic protection is feasible. The results of slow strain rate tensile tests show that the stress corrosion cracking sensibility is high and cathodic protection effect is restricted due to the hydrogen permeation. However, the elongation, yielding strength and tensile strength all increase with anodic protection. The higher anodic protection potential in the stable passive region is benefit to improve tensile strength and yielding strength. However, the higher elongation is obtained at 0.5V (SCE) anodic protection potential.
PL
Badania polaryzacji potencjodyniamicznej oraz próby powolnego rozciągania (SSRT) przeprowadzono na stali typu X80 w roztworze 0,5M Na2CO3-1M NaHCO3. Określono odporność na korozję elektrochemiczną oraz zbadano zjawisko naprężeniowego pękania korozyjnego. Rezultaty badań polaryzacji potencjodynamicznej wykazały istnienie stabilnego obszaru pasywacji w zakresie potencjału od 0V do 0,8V (SCE: półogniwo odniesienia – elektroda kalomelowa). Próby powolnego rozciągania pokazały wysoką wrażliwość materiału na naprężeniowe pękanie korozyjne i ograniczenia ochrony katodowej w związku z przenikaniem wodoru. Ochrona anodowa natomiast, zwiększa znacząco wydłużenie próbki, granicę plastyczności oraz wytrzymałość na rozciąganie. Ponadto zwiększanie wartości potencjału w stabilnym obszarze pasywacji dodatkowo poprawia te właściwości.
5
Content available remote Wpływ obróbki anodowej na kozoryjną odporność tytanu i stopu Ti6Al4V
PL
Przedstawiono badania wpływu parametrów pasywacji anodowej czystego tytanu i stopu T16A14V na odporność na korozję w roztworze fizjologicznym Tyrode'a. Na podstawie badań elektrochemicznych określono wpływ składu kąpieli, napięcia oraz czasu pasywacji na potencjał korozyjny i szybkość korozji. Wyznaczono optymalne warunki prowadzenia procesu pasywacji elektrochemicznej dla próbek poddanych procesowi polerowania elektrolityc-nego (średnia chropowatość Ra = 0,16
EN
Investigations of the influence of the conditions of an anodic passivation of titanium and Ti6Al4V alloy on corrosion resistance in Tyrode's physiological solution have been presented. On the grounds of electrochemical investigations the influence of chemical composition of the bath, voltage and passivation time on corrosion potential and corrosion rate have been determined. The optimum conditions of electrochemical passivation process for samples after electrochemical polishing (with the mean roughness Ra = 0,16 \un) have been given.
6
Content available remote Ochrona anodowa stali nierdzewnych za pomocą powłok z polimerów przewodzących
PL
W pracy przedstawiono wyniki badań korozyjnych prowadzonych dla stali 2H13 pokrytej warstwami wybranych polimerów przewodzących: polianiliny, polipirolu i poli-N-metylopirolu w silnie kwaśnych środowiskach. Elektroosadzanie powłok prowadzono metodą galwanostatyczną. Szybkość korozji stali pokrytej poszczególnymi powłokami wyznaczono na podstawie analizy roztworu korozyjnego na zawartość jonów Fe i Cr z wykorzystaniem absorpcji atomowej. Przeprowadzono pomiary poten-cjału korozyjnego w funkcji czasu ekspozycji w badanych roztworach umożliwiające ocenę własności ochronnych powłok.
EN
This work summarises the results of corrosion studies aiming at comparison of protective properties of films prepared from selected conduct-ing polymers: polyaniline, polypyrrole and poly-N-methylpyrrole on stainless steel substrate. The respective films were electrodeposited galvanos-tatically on the steel surface. Protective properties of conducting polymer films in strongly acid solutions were evaluated from the measurement of the corrosion potential of steel and from the determinations of the iron and chromium dissolution rate on the basis of atomic absorption analyses of these metals in the corrosion solutions.