Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  occlusion forces
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Experimental evaluation of occlusal forces
EN
The paper presents the results of measuring the occlusion forces in the group of 163 subjects being tested. In the research, the method based on the dependence of the plastic deformity and force intending the spherical penetrator upon each other in a metal sample was implemented. The results obtained allowed us to estimate the distribution of occlusion forces along the alveolar ridge and to define the dimensions of the maximum forces applied, while biting and gnawing. The biting force between the first incisors for different angles of parting mandible was also measured.
PL
W pracy przedstawiono wyniki badań oddziaływania wybranych konstrukcji metalowych stosowanych w rekonstrukcji uzębienia na zmiany rozkładów w tkankach naturalnych. Wykorzystując metodę elementów skończonych, zamodelowano wpływ sił okluzyjnych na naprężenia w układzie kostnym w strefie kotwiczenia implantów stomatologicznych systemu Branemarka stanowiących filary implantoprotezy pojedynczego zęba. Analizie poddano takie czynniki, jak długość implantu oraz kierunek jego wprowadzenia. Stwierdzono istotną różnicę wytężenia tkanki kostnej w stosunku do stanu naturalnego. Uzyskane wyniki wskazują na możliwość wpływania na wielkość naprężeń poprzez odpowiedni dobór długości wszczepu. Kolejnym analizowanym sposobem przywracania wydolności narządu żucia były metody całkowitej rekonstrukcji korony zęba wykorzystujące prefabrykowane wkłady koronowo-korzenne. Przy zastosowaniu tych metod, biomechaniczne warunki pracy przyzębia nie ulegają zmianie. Zmienia się natomiast sposób obciążenia pozostałych tkanek zęba własnego. Stwierdzono, że zarówno dla zębów jednokorzeniowych, jak i wielokorzeniowych, metalowe konstrukcje poprawiające retencję materiału rekonstrukcyjnego przejmują rolę twardych tkanek zęba. Ze względu na zdarzające się przypadki pęknięcia korzenia z założonym wkładem, następujące przeważnie w wyniku urazu, przeanalizowano wpływ długości części korzeniowej wkładu na wytężenie ścianki korzenia. Stwierdzono, że zbyt bliska odległość końca wkładu od otworu fizjologicznego będzie sprzyjać mechanicznym uszkodzeniom korzenia. Wyniki przedstawiono w postaci map i wykresów naprężeń redukowanych.
EN
Investigation results of interaction of selected metal structures used in the dentition reconstruction on the changes in the stress distribution in natural tissues are presented in this article. Using the final elements method an influence of occlusion forces on stresses in the osseous system in the zone of hooking the dental implants of Branemark's system being the implantoprosthesis pillar of a single tooth has been modelled. The length of an implant and the direction of its insertion were the factors subjected to an analysis. A significant difference of the bone tissue effort was found in comparison to the natural state. the obtained results show that is possible to influence the value of stresses by an appropriate selection of the implant length. Methods of the total reconstruction of the tooth crown using prefabricated crown-root inlays were another analysed way of restoring efficiency of masticatory organ. By using those methods, biomechanical working conditions of the parodontium do not undergo changes. However, a way of loading of the other tissues of the natural tooth is changed. It has been found that for both monoradicular and multiradicular teeth, metal structures improving retention of the reconstruction material take over the function of hard tissues of a tooth. Due to cases of cracking of a root with the inserted inlay, occuring mainly as a result of trauma, an influence of the length of the radicular part of an inlay on effort of the root wall was analysed. It has been found that too close distance of the inlay end from a physiological opening will favour mechanical damages of the root. The results were presented in the form of maps and diagrams of reduced stresses.
PL
W pracy przedstawiono nową metodę pomiaru sił zgryzu opartą na zależności pomiędzy wielkością odcisku w blasze aluminiowej a siłą wgniatającą penetrator w kształcie kulki. Metodę sprawdzono dokonując badań klinicznych 120 osób. Uzyskane wyniki pozwoliły na ocenę rozkładu sił zgryzu wzdłuż łuku zębowego oraz określenie maksymalnych sił pomiędzy zębami trzonowymi i przedtrzonowymi.
EN
The work presents the new method of measuring the occlusion forces and the results of investigations in a group of 120 tested subjects. In the research the method based on interdependence between the plastic deformity and force indenting the spherical penetrator in the metal sample was implemented. The obtained results allowed to estimate the distribution of occlusion forces along the alverolar ridge and define the dimensions of the maximum forces applied while biting and gnawing.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.