This paper proposes a single pole eight throw switch (SP8T) using cascaded single pole double throw (SPDT) switches. The switch design is to control eight antenna array in the monostatic microwave imaging system for medical application. A mathematical modeling was done for a simple series-shunt SPDT switch for the analysis of insertion loss, return loss and isolation. Then, a proper selection of SPDT switch topologies was carried out in a simulation software in order to get ultra wideband (UWB) performance of the SP8T switch design. As a result, the proposed SP8T switch produced 9.3 GHz of isolation bandwidth that can be used for a Gaussian pulse up to 9.3 GHz bandwidth (from 1.7 GHz to 11 GHz frequency spectrum).
PL
W niniejszym artykule zaproponowano jednobiegunowy przełącznik ośmiorurowy (SP8T) wykorzystujący kaskadowe jednobiegunowe przełączniki dwustanowe (SPDT). Konstrukcja przełącznika służy do sterowania układem ośmiu anten w monostatycznym mikrofalowym systemie obrazowania do zastosowań medycznych. Przeprowadzono modelowanie matematyczne prostego przełącznika SPDT z bocznikiem szeregowym do analizy tłumienia wtrąceniowego, tłumienia odbiciowego i izolacji. Następnie dokonano właściwego wyboru topologii przełącznika SPDT w oprogramowaniu symulacyjnym, aby uzyskać wydajność ultraszerokopasmową (UWB) projektu przełącznika SP8T. W rezultacie proponowany przełącznik SP8T wytworzył pasmo izolacji 9,3 GHz, które można wykorzystać dla impulsu Gaussa o szerokości do 9,3 GHz (widmo częstotliwości od 1,7 GHz do 11 GHz).
2
Content available remote Design of a high directive sensor for microwave imaging application
EN
This paper presents a compact uniplanar Vivaldi antenna sensor for microwave imaging. It is ideal for microwave imaging systems with its large bandwidth and end-fire radiation performance. The Vivaldi patches integrate a coplanar waveguide (CPW) feed line, ensuring the entire structure is compact and simple. Reflection coefficient, radiation pattern, gain, efficiency, and directivity were the antenna parameters analyzed to determine the Vivaldi antenna's performance. The bandwidth of the antenna sensor is wider, approximately 5 GHz (3-8 GHz). The gain of the antenna is 6.72 dBi, and the directivity is 9.59 dBi.
PL
W artykule przedstawiono kompaktowy jednopłaszczyznowy czujnik antenowy Vivaldiego do obrazowania mikrofalowego. Jest idealny do systemów obrazowania mikrofalowego dzięki dużej szerokości pasma i wydajności promieniowania końcowego. Łaty Vivaldi integrują współpłaszczyznową linię zasilającą falowodu (CPW), zapewniając, że cała konstrukcja jest zwarta i prosta. Współczynnik odbicia, charakterystyka promieniowania, wzmocnienie, wydajność i kierunkowość były parametrami anteny analizowanymi w celu określenia wydajności anteny Vivaldi. Szerokość pasma czujnika anteny jest szersza, około 5 GHz (3-8 GHz). Zysk anteny wynosi 6,72 dBi, a kierunkowość 9,59 dBi.
EN
A directive three dimensional antenna, using folded radiating structure has been presented for the application of microwave imaging in clinical diagnosis. Two reflector walls have been introduced to achieve higher gain and directive radiation pattern along with the folding technique. The shorting wall technique is utilized to reduce the overall antenna size and to get resonance at a lower frequency. The proposed antenna obtained operating band at 1.67 GHz to 1.74 GHz. The dimension of the 3D radiating structure is 40£25£10.5 mm3. The antenna has an average realized gain of 5.2 dBi. Owing to the unidirectional radiation pattern, high gain and operating bandwidth within lower microwave frequency, the proposed antenna has potential to be used in microwave imaging for biomedical diagnosis. Also, the antenna has been utilized to compute an imaging phenomenon to detect abnormality in human head and result is presented. The design and simulation process are performed in the CST Microwave Studio software. The antenna is fabricated from 0.2 mm thick copper sheets. The results of the fabricated antenna are measured using PNA Network Analyzer (N5227A) and Satimo Star Lab.
4
Content available remote Variational Bayesian inversion for microwave breast imaging
EN
Microwave imaging is considered as a nonlinear inverse scattering problem and tackled in a Bayesian estimation framework. The object under test (a breast affected by a tumor) is assumed to be composed of compact regions made of a restricted number of different homogeneous materials. This a priori knowledge is defined by a Gauss-Markov-Potts distribution. First, we express the joint posterior of all the unknowns; then, we present in detail the variational Bayesian approximation used to compute the estimators and reconstruct both permittivity and conductivity maps. This approximation consists of the best separable probability law that approximates the true posterior distribution in the Kullback-Leibler sense. This leads to an implicit parametric optimization scheme which is solved iteratively. Some preliminary results, obtained by applying the proposed method to synthetic data, are presented and compared with those obtained by means of the classical contrast source inversion method.
5
Content available Numeryczne modele gruczołu piersiowego
PL
W artykule zostały przedstawione modele numeryczne gruczołu piersiowego uzyskane przy pomocy obrazów MRI. Modele te pozwalają lepiej zobrazować zmiany zachodzące w gruczole piersiowym poprzez uzyskane dość dokładne właściwości tkanki.
EN
In this paper were presented numerical breast phantoms, obtained using MRI. These phantoms allow better illustrate changes setting in breast through obtained fairly accurate characteristics of tissue.
6
Content available remote Numerical models of human breast
EN
The aim of the paper is to introduce the online repository of numerical breast models, obtained using MRI. These free available models allow to better illustrate changes setting in breast through obtained fairly accurate characteristics of tissues i.e. the models assemble the structural heterogeneity of normal breast tissues and the realistic dispersive dielectric properties in frequency range 0.5-20 GHz based on Debye’s model.
PL
Celem artykułu jest prezentacja darmowego repozytorium naturalistycznych, numerycznych modeli gruczołu piersiowego i jego krótkie omówienie. Modele te pozwalają zobrazować heterogeniczną budowę gruczołu piersiowego, a także odwzorować właściwości dyspersyjne jego tkanek w zakresie częstotliwości 0.5-10 GHz w oparciu o parametryczny model Debye’a.
7
Content available remote Jakość obrazowania w tomografii wielościeżkowej
PL
Współczesne tomograficzne techniki pomiarowe pozwalają na dość dokładne monitorowanie badanych obiektów. Praca przedstawia problematykę uzyskiwania odwzorowań tomograficznych o wysokiej jakości. W pracy zamieszczono przykład badań symulacyjnych obiektu o złożonym kształcie. Zastosowane metody umożliwiły uzyskanie obrazów tomograficznych wiernie odwzorowujących badane fantomy.
EN
Today tomographic measurement techniques allow fairly accurate monitoring of the test objects. The work presents the problem of obtaining high quality tomography images. This paper contains examples of simulation researches of the complex shape objects. Chosen methods made it possible to obtain tomographic images that accurately map tested phantoms.
PL
Praca niniejsza ma na celu przedstawienie możliwości, jakie daje zastosowanie tomografii mikrofalowej do detekcji nowotworu gruczołu piersiowego. W celu uproszczenia zagadnienia założono, że model gruczołu piersiowego jest homogeniczny, a jego parametry elektryczne (przenikalność elektryczna względna i konduktywność) opisane są równaniem Debye'a. Parametry elektryczne zostały przeliczone dla częstotliwości 6 GHz. Artykuł przedstawia właściwości dielektryczne tkanki dla fantomu piersi. Zmiany patologiczne obrazujące nowotwór gruczołu piersiowego naniesione są na sztuczne modele piersi, o których mowa w pracy.
EN
The aim of this paper is the application of microwave tomography to breast cancer detection. In order to investigate the problem, the authors assumed that the model of breast is homogeneous and its electrical parameters i.e. dielectric constant and conductivity are described (approximately) by Debye's formula. The model, its dimensions and electrical parameters calculated for frequency of 6 GHz. This article introduced the approach to the dielectric properties of breast tissue inside the breast phantom. Artificial changes, such as changes to models illustrating the tumor may be achieved on the healthy breast phantoms, as referred to in the workplace.
PL
Zaprezentowano model laboratoryjny mikrofalowego systemu obrazującego. System ten pozwala na uzyskanie przekroju poprzecznego obiektu umieszczonego na stole obrotowym i oświetlanego pod różnymi kątami ultrakrótkimi impulsami mikrofalowymi. Omówiono uproszczony model matematyczny systemu, wyniki symulacji komputerowych oraz wyniki pomiarów.
EN
The paper concerns a laboratory model of microwave imaging system. It allows obtaining the cross-section of the object under test located on a revolving platform and excited with ultra short microwave pulses. The cross-section is calculated on a base of raw measurement data matrix constituted by the received signals, reflected from the object under test for subsequent angle locations. Paper presents mathematical model of the system, the results of computer simulations as well as measurement results.