Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  obciążenie hydrauliczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the results of the analysis concerning the verification of the actual hydraulic load and the load of organic pollutants compared to the conditions designed for 4 household wastewater treatment plants. The researches were carried out in the annual period from May 2015 to April 2016. Based on the conducted analysis, it was found that objects act as underloaded hydraulically and the actual inflow of sewage to the analysed objects during the research period ranged from 7.3% to 32.7% in relation to the inflow assumed in the project. Furthermore, in the case of loading the treatment plant with the load of pollutants expressed as PE, it was fund that the actual PE values were lower than assumed in the project. Therefore, it is important that the sizes of the series of household sewage treatment plants were selected depending on the individual conditions of household, i.e. the number of inhabitants or the amount of consumed water.
PL
W pracy przedstawiono wyniki analizy dotyczące weryfikacji rzeczywistego obciążenia hydraulicznego oraz obciążenia ładunkiem zanieczyszczeń organicznych w porównaniu z warunkami projektowanymi dla czterech przydomowych oczyszczalni ścieków. Badania prowadzono w rocznym okresie – od maja 2015 r. do kwietnia 2016 r. Na podstawie przeprowadzonej analizy stwierdzono, że obiekty działają jako niedociążone hydraulicznie, a rzeczywisty dopływ ścieków do analizowanych obiektów w okresie badań wyniósł od 7,3% do 32,7% w stosunku do dopływu zakładanego w projekcie. Również w przypadku obciążenia oczyszczalni ładunkiem zanieczyszczeń wyrażonych jako RLM, stwierdzono, że rzeczywiste wartości RLM były niższe, niż zakładane w projekcie. Zatem ważne jest, aby wielkości typoszeregów przydomowych oczyszczalni ścieków były dobierane w zależności od indywidualnych uwarunkowań gospodarstw domowych, tj. liczby mieszkańców lub ilości zużywanej wody.
EN
The aim of the study was to determine the impact of selected factors on the reduction of organic pollutants, expressed in BOD5 and CODCr, in wastewater treated in a laboratory scale model of moving bed biofi lm reactor (MBBR). The factors included in the experiment: the degree of fi lling the fluidized bed with biomass carriers, hydraulic load, and aeration intensity. The tested model of the bioreactor consisted of five independent chambers with diameter D = 0.14 m and height H = 2.0 m, which were fi lled with biomass carriers at 0%, 20%, 40%, 60%, 70% of their active volume. During the test period, hydraulic loads at the level of Qh1 = 0.073 m3·m-2·h-1 and Qh2 = 0.073 m3·m-2·h-1were applied, which ensured one-day and two-day sewage retention, respectively. The said reactors were subjected to constant aeration at P1 = 3.0 dm3·min-1 and P2 = 5.0 dm3·min-1. The highest efficiency of the reduction of the analysed indicators was demonstrated by reactors filled with carriers in the degree of 40–60%. Based on the statistical analyses (the analyses of the ANOVA variations and the Kruskal-Wallis test) carried out, it was found that the studied factors significantly modified the mutual interaction in the process of reducing BOD5 in treated wastewater of the reactors tested. The significance of the impact of the discussed factors on the values of the studied indicators in treated wastewater depends on mutual interactions between the investigated factors.
PL
Celem badań było określenie wpływu wybranych czynników na zmniejszenie zanieczyszczeń organicznych, wyrażonych wskaźnikami BZT5 i ChZTCr, w ściekach oczyszczanych w modelu reaktora przypływowego ze złożem ruchomym typu MBBR. Czynniki, które uwzględniono w eksperymencie to: stopień wypełnienia złoża nośnikami biomasy, obciążenie hydrauliczne oraz intensywność napowietrzania. Badany model bioreaktora stanowił pięć niezależnych komór o średnicy D = 0,14 m i wysokości H = 2,0 m, które były wypełnione nośnikami biomasy w stopniu: 0%, 20%, 40%, 60%, 70% ich objętości czynnej. W okresie badań zastosowano obciążenia hydrauliczne na poziomie Qh1 = 0,073 m3·m-2·h-1 oraz Qh2 = 0,073 m3·m-2·h-1, co zapewniało odpowiednio jednodobowe oraz dwudobowe zatrzymanie ścieków. Przedmiotowe reaktory poddawane były stałemu napowietrzaniu na poziomie P1 = 3,0 dm,3min-1 oraz P1 = 3,0 dm3min-1 = 5,0 dm3·min-1. Największą skuteczność redukcji analizowanych wskaźników wykazywały reaktory wypełnione kształtkami w stopniu 40–60%. Na podstawie przeprowadzonych analiz statystycznych (analiza wariacji ANOVA oraz test Kruskala-Wallisa) stwierdzono, iż badane czynniki istotnie modyfikowały wzajemne oddziaływanie na siebie w procesie zmniejszania BZT5 w ściekach oczyszczonych badanych. Istotność wpływu omawianych czynników na wartości badanych wskaźników w ściekach oczyszczonych, zależy od wzajemnych interakcji między badanymi czynnikami.
PL
Zarówno zbyt duża, jak i zbyt mała objętość ścieków dopływających do oczyszczalni, w odniesieniu do tej, która została określona na etapie projektowania może przyczynić się do obniżenia skuteczności usuwania zanieczyszczeń. Mając to na uwadze, w niniejszym artykule dokonano analizy ilości ścieków odprowadzanych w latach 2013–2015 z terenu aglomeracji Sanok i unieszkodliwianych na lokalnej oczyszczalni. Przeprowadzona analiza wykazała, że oczyszczalnia w Trepczy w każdym roku analizowanego okresu przyjmowała ścieki w podobnych ilościach, nieprzekraczających wielkości projektowej przepustowości obiektu, o czym świadczą wyznaczone wartości dopływów średniodobowych. Zauważa się, że okresach bezdeszczowych do oczyszczalni dopływały mniejsze ilości ścieków niż w dniach z pogodą mokrą. Pomimo okresowo występujących sytuacji przeciążenia i niedociążenia hydraulicznego obiektu, można stwierdzić, że skuteczność zachodzących tam procesów oczyszczania nie jest zagrożona nadmierną bądź niedostateczną ilością dopływających ścieków.
EN
Both too large and too small volume of sewage inflowing to wastewater treatment plant in relation to its volume determined during designing process, can contribute to the reduction of sewage treatment effectiveness. Taking into consideration, in this article, the analysis of the sewage quantity discharging from the Sanok agglomeration and treated in domestic wastewater treatment plant in 2013–2015 was performed. The analysis indicated that in each year of the analyzed period, to the Wastewater Treatment Plant in Trepcza, a similar volumes of sewage was inflowing and the maximum hydraulic capacity of the object was not exceeded, what is evidenced by the average daily sewage flow values. It is noted that in rainless periods, the quantities of inflowing sewage were smaller than during days with wet weather. Despite of periodically situations of the hydraulic overload and hydraulic underload, it can be stated that the effectiveness of the sewage treatment processes is not endangered by the excessive or insufficient quantities of inflowing sewage.
PL
Nierównomierność dopływajqcych ścieków, jak również towarzyszące im często zmiany jakościowe stanowią zasadniczy czynnik powodujący zakłócenia w prawidłowym przebiegu procesów oczyszczania ścieków. W pracy przedstawiono analizę dynamiki dopływu ścieków do oczyszczalni w Bieczu w 2016 roku. Dokonano analizy w ujęciu rocznym, miesięcznym, tygodniowym, kwartalnym oraz z podziałem na cztery pory roku (zima, wiosna, lato, jesień). Na podstawie analizy obciążenia hydraulicznego obiektu w Bieczu zaprezentowano problem zmienności dopływu ścieków do reaktorów SBR. Badania wykazały, że znajomość dynamiki dopływu ścieków do oczyszczalni pozwala na optymalizację pracy reaktorów porcjowych.
EN
Uneven wastewater inflow and the associated qualitative changes are a major factor in disrupting the normal course of wastewater treatment processes. The paper presents an analysis of the dynamics of the wastewater inflow to the Biecz WWTP in 2016. Annual, monthly, weekly, quarterly, and four seasons (winter, spring, summer, autumn) were analyzed. Based on the analysis of the hydraulic load of the wastewater treatment plant in Biecz, the problem of variation of the wastewater flow to the SBR reactors was presented. Studies have shown that knowledge of the dynamics of dynamics of wastewater flow to the wastewater treatment plant is used for optimizing the work of sequencing batch reactor.
5
Content available remote Hydrauliczne warunki pracy sekwencyjnego reaktora porcjowego
PL
Specyficzną cechą sekwencyjnych reaktorów porcjowych jest sposób napełniania, który warunkuje charakterystykę hydrauliczną systemu. W zależności od sposobu napełniania reaktora ściekami, można wyodrębnić trzy zasadnicze warianty technologii SBR: (I) system z ciągłym doprowadzaniem ścieków, w którym czas trwania napełniania równy jest długości cyklu; (II) system z okresowym napełnianiem reaktora bez wstępnego zbiornika retencyjnego; (III) system z okresowym napełnianiem reaktora z zastosowaniem zbiornika retencyjnego. W pracy zaprezentowano analizę hydrauliczną oczyszczalni ścieków komunalnych składającej się z dwóch sekwencyjnych reaktorów porcjowych. Obiekt badawczy stanowiła oczyszczalnia ścieków o przepustowości Qśrd = 500 m3/d i 4200 RLM. Badania hydraulicznych warunków pracy sekwencyjnych reaktorów porcjowych polegały na analizie sposobu ich napełniania w czasie. Badania przeprowadzono w okresie wiosennym podczas pogody bezdeszczowej dla okresu 7-dniowego – od poniedziałku do niedzieli.
EN
The filling method is a specific feature of sequential batch reactors because it determines the hydraulic characteristics of the system. Depending on the method of filling the reactor, three main SBR variants can be distinguished: (I) a system with a continuous supply of wastewater, where the filling time is equal to the cycle length; (II) system with periodic filling of the reactor without retention tank; (III) system with periodic filling of the reactor using a retention tank. The paper presents a hydraulic analysis of a municipal wastewater treatment plant consisting of two sequencing batch reactors. The research facility was a WWTP with a capacity of 500 m3/d and 4200 PE The study of the hydraulic operating conditions of sequencing batch reactors was based on an analysis of the way they were filled in time. The study was conducted during the spring weather during the 7-day rain-free period from Monday to Sunday.
EN
The paper presents an analysis of hydraulic load in a wastewater treatment plant (WTP) in Jasło. The study was based on the records of daily sewage volume entering the treatment plant within a multi-year period of 2010–2014. The analysis took into account the average daily amount of incoming sewage, the maximum daily peaking factor for the incoming sewage, changes in the sewage volume depending on specific month and day of a week, and class intervals with the greatest frequency of occurrence. The analysis revealed that the average daily volume of the sewage entering the WTP in Jasło in the investigated multi-year period was 13 045 m3·d–1. The amount of incoming sewage was variable, as evidenced by the maximum peaking factors of daily sewage inflow that ranged from 1.07 to 2.78, depending on a specific month. The sewage admission was the largest in March, May and June and on Saturdays. Sewage volume interval most often occurring at the WTP in Jasło was the one between 8 000 and 10 000 m3·d–1. The study results indicated that the facility was hydraulically underloaded.
PL
W artykule przedstawiono analizę obciążenia hydraulicznego oczyszczalni ścieków w Jaśle. Badania przeprowadzono na podstawie rejestrów dobowych objętości ścieków dopływających do oczyszczalni w wieloleciu 2010–2014. Wyznaczono średnią dobową ilość dopływających ścieków w badanym pięcioleciu, określono maksymalne współczynniki nierównomierności dobowej dopływu ścieków, kształtowanie się wielkości dopływu w poszczególnych miesiącach oraz dni tygodnia analizowanego wielolecia i wyznaczono przedziały klasowe, w których najczęściej pojawiały się dopływy ścieków. Na podstawie przeprowadzonej analizy stwierdzono, że średnia dobowa ilość ścieków dopływających do oczyszczalni w Jaśle w rozpatrywanym wieloleciu wynosi 13 045 m3·d–1. Ilość dopływających ścieków charakteryzuje się nierównomiernością, o czym świadczą wielkości maksymalnych współczynników nierównomierności dobowej dopływu ścieków, które w poszczególnych miesiącach przyjmowały wartości z przedziału od 1,07 do 2,78. Ponadto stwierdzono, że największe dopływy ścieków występują w miesiącach: marzec, maj, czerwiec, a w ciągu tygodnia – w soboty. Analiza częstości wystąpienia poszczególnych ilości ścieków dopływających do jasielskiej oczyszczalni wykazała, że najczęściej pojawiającym się dopływem był dopływ przyjmujący wartości z przedziału od 8 000 do 10 000 m3·d–1. Bazując na uzyskanych wynikach, stwierdzono, że oczyszczalnia ścieków w Jaśle pracuje w warunkach niedociążenia hydraulicznego.
PL
Jedna z metod oczyszczania ścieków komunalnych pozwala na zastosowanie złóż biologicznych. W badaniach zastosowano złoże wypełnione haloizytem. Podczas pracy złoża w zależności od zastosowanego obciążenia hydraulicznego uzyskano redukcję stężeń fosforanów, azotu amonowego i materii organicznej. Najwyższą redukcję PO43- (89%) i N–NH4+ (81%) w ściekach uzyskano przy obciążeniu hydraulicznym złoża wynoszącym 0,04 m3/m2h. Stężenie substratu organicznego uległo redukcji o ok. 86%.
EN
One of the methods of municipal wastewater treatment allows the use of biofilters. The study used a bed filled halloysite. In operation of the bed, depending on the hydraulic load, the concentration of phosphate, ammonium and organic matter was reduced. Highest reduction of the concentration PO43- (89%) and NH4+ (81%) in the waste water of the hydraulic load –0,04 m3/m2h.was obtained. The concentration of the organic substrate was reduced by approximately 86%.
PL
W artykule przedstawiono analizę obciążenia hydraulicznego wybranych oczyszczalni powiatu jasielskiego: w Przysiekach, Kołaczycach oraz Szebniach. Badania przeprowadzono w oparciu o rejestry dobowe objętości ścieków, dopływających do oczyszczalni, w latach 2011–2014. Wyznaczono średnie dobowe objętości ścieków dopływających, określono wielkości maksymalnych współczynników nierównomierności dobowej dopływu ścieków, określono kształtowanie się wielkości dopływu ścieków w poszczególnych miesiącach oraz wyznaczono przedziały klasowe w których najczęściej pojawiały się poszczególne wielkości dopływów. Na podstawie przeprowadzonej analizy stwierdzono, że badane oczyszczalnie pracują w warunkach niedociążenia hydraulicznego. Ponadto stwierdzono, znaczną nierównomierność ilości ścieków, dopływających do obiektów w Przysiekach oraz Szebniach. Dodatkowo zauważono, że największe dopływy ścieków, do analizowanych oczyszczalni, wystąpiły w okresie wczesnowiosennym oraz letnim. Najczęściej pojawiającym się dopływem ścieków do oczyszczalni w Przysiekach był dopływ z przedziału od 320 do 480 m3·d-1, dla oczyszczalni w Kołaczycach z przedziału od 290 do 320 m3·d-1, a dla obiektu w Szebniach z przedziału od 120 do 240 m3·d-1.
EN
The paper presents the analysis of hydraulic load in selected wastewater treatment plants (WTP) in Jasło County: in Przysieki, Kołaczyce and Szebnie. The study was based on the records of daily sewage volume entering the treatment plants within a multi-year period of 2011–2014. The analysis took into account the average daily amount of incoming sewage, the maximum daily peaking factor for the incoming sewage, changes in the sewage volume depending on specific month and the intervals with the greatest frequency of occurrence were designated. The analysis revealed that investigated wastewater treatment plants were hydraulically underloaded. Moreover, it significant variables of the amount of inflowing sewage were observed. The sewage admission was the largest in spring and summer periods. Sewage volume interval most often occurring at the WTP in Przysieki was the one between 320 and 480 m3·d-1.
PL
Przedstawione wyniki badań przedstawiają zakres oraz zmienności temperatury ścieków w otwartych bioreaktorach przepływowych niedociążonych hydraulicznie. W obu bioreaktorach występowały duże wahania temperatury ścieków od 6°C do 19 °C. Stwierdzono duży wpływ temperatury powietrza atmosferycznego na temperaturę ścieków w bioreaktorach. Stwierdzono, iż wraz ze zmianą temperatury powietrza atmosferycznego o 1°C następuje zmiana temperatury ścieków o 0,40°C w bioreaktorze A i o 0,38°C w bioreaktorze B.
EN
The results of the researches showed range and variability of sewage temperature in open flow hydraulically underloaded bioreactor. In both reactors great range of sewage temperature amounted from 6°C to 19 °C were observed. It was ascertained a great influence of air temperature on sewage temperature in bioreactors. Also, together with change of air temperature about 1°C a change of sewage temperature about 0,4°C in Al bioreactor and 0,3 8°C in В bioreactor were observed.
PL
W artykule przedstawiono analizę wyników modelowania ogólnospławnego systemu kanalizacji ogólnospławnej dla zlewni o dużej powierzchni. Zastosowano program SWMM v.5.0 zaadaptowany do wprowadzania opadu o intensywności przestrzennie zmiennej. Symulację funkcjonowania systemu kanalizacyjnego przeprowadzono dla rzeczywistych zlewni w Łodzi przy wykorzystaniu danych z monitoringu opadów na terenie miasta w roku 2010 i 2011. Na tej podstawie porównano wyniki obliczeń dla opadów przestrzennie zmiennych oraz punktowych zadanych dla całej zlewni. Ta ostatnia opcja prowadzić może do istotnego zawyżania lub zaniżania wyników obliczeń.
EN
This article presents the results of computer simulations of existing combine sewerage system with the use of the SWMM v.5.0 software. The software input format has been adopted for the case of spatially distributed rainfalls. Rainfall data obtained from a municipal monitoring system were used for modeling runoff from two large urban catchments in Łódź. On the basis of the results, the comparison of flows obtained for the spatially distributed and standard static rainfalls has been made. It was demonstrated that the option of static rainfalls usually leads to significant overestimation of flows (however in some case underestimation is also possible). For that reason, there is an urgent need to verify the present rules and methods for dimensioning sewerage systems draining large urban catchments.
PL
Przedstawiono problemy towarzyszące pracy chłodni kominowych przy szeroko zmiennym obciążeniu cieplnym i hydraulicznym. Stosując strefowy wodorozdział, instalację natryskową i rurociągi bezpośredniego zrzutu, połączone w system, możliwa jest regulacja temperatury wody ochłodzonej, zapewniająca bezpieczną pracę chłodni w okresie zimowym.
EN
Natural draught cooling towers performance problems in wide change of heat duty and water flow has been pressented. Water distribution system with separated zones together with spraying system and by-pass pipes are used to control recooled water temperature and antifreezing protection.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.