Roller blinds are devices that are retracted and wrapped in a box above the window opening and are used to protect against the solar radiation. Those are the well-known devices with distinct advantages over the fixed external dimming elements. The influence of external blinds on the internal thermal environment in climatic conditions in the Republic of Serbia, the city of Kragujevac, was considered in this research. An external blind was installed in the test room and its influence on the internal temperature was compared with the internal temperature of the room without the blind. Real-time monitoring was carried out in February and August 2023. The results presented in this paper show that the blind reduces the temperature in summer by 3.57ºC and increases it in winter by 1.76ºC. The cooling load can be reduced by about 20%, and the heat load by about 15%.
EN
The paper presents the assumptions and methodology for investigating equivalent heat load testing of hot aircraft engine components. The basic heat loads occurring in an aircraft engine during aircraft flight are characterised. Diagrams of the proposed heat loads are presented, together with the number of cycles, and a test bench is characterised and shown to enable equivalent heat load testing of aircraft engine components.
PL
Ocena wydajności systemu ogrzewania stropowego w budynku wymaga uwzględnienia temperatury zewnętrznej obliczeniowej i średniorocznej w pomieszczeniach oraz współczynników przenikania ciepła przegród. Przeanalizowano właściwości grzejne stropu DX-Therm na przykładzie budynku mieszkalnego zlokalizowanego w trzech sąsiadujących krajach europejskich. Rozwiązanie okazuje się energooszczędne i komfortowe we wszystkich mieszkaniach w Polsce i Niemczech. Poddano dyskusji możliwość dostosowania go do warunków ukraińskich. Scharakteryzowano cechy termoaktywnego stropu prefabrykowanego.
EN
The assessment of the performance of a ceiling heating system in a building requires the consideration of room, external design and average annual temperature values and building envelope heat transfer coefficients. The DX-Therm ceiling heating properties have been analysed for three neighbouring European countries using an apartment building as an example. The solution proves to be energy efficient and comfortable in all apartments in Poland and Germany. The possibility of adapting it to the Ukrainian conditions is discussed. The features of the thermoactive prefabricated ceiling are characterised.
PL
Tematem artykułu jest analiza wpływu sposobu obliczeń strat ciepła do przestrzeni nieogrzewanych (piwnicy i poddasza) budynku na jego parametry energetyczne, tj. na obciążenie cieplne i zużycie energii użytkowej. Rozpatrzono trzy metody obliczeń przedstawione w normie PN–EN 12831:2006 „Instalacje ogrzewcze w budynkach. Metoda obliczania projektowego obciążenia cieplnego” przy różnych sposobach ocieplenia rozpatrywanego budynku wielorodzinnego. Wykazano, że zastosowanie do obliczeń potrzeb cieplnych budynku stałej wartości współczynnika redukcji temperatury lub stałej temperatury przestrzeni nieogrzewanej wiąże się z przeszacowaniem strat ciepła przez przegrody budowlane oddzielające przestrzeń ogrzewaną od nieogrzewanej, co sprawia, że model obliczeniowy budynku nie jest dostosowany do rzeczywistych warunków eksploatacji obiektu.
EN
The subject of the article is the analysis of the influence of the method of calculating heat losses to unheated spaces (basement and attic) of a building on its energy parameters, i.e. heat load and useful energy consumption. Three calculation methods presented in the standard PN – EN 12831: 2006 “Heating Systems in Buildings – Method for Calculation of the Design Heat Load” with different methods of thermal insulation of the considered multi-family building. It has been shown that the use of a constant value of the temperature reduction coefficient or a constant temperature of an unheated space to calculate the thermal needs of a building is associated with an overestimation of the heat loss through building partitions separating the heated and unheated space, which means that the building calculation model is not adapted to the actual operating conditions of the building
PL
Specyficzną cechą systemów ciepłowniczych jest fakt, że obciążenie cieplne systemu charakteryzuje się dużą zmiennością w ciągu roku. Do analizy tej zmienności mającej wielorakie zastosowanie wykorzystywany jest wykres obciążeń cieplnych. Podstawą sporządzania wykresu obciążeń jest zmienność temperatury powietrza zewnętrznego charakterystyczna dla lokalizacji obiektu, dla którego sporządzany jest wykres. W metodologii sporządzania wykresu zakłada się w każdej chwili proporcjonalność strat ciepła na ogrzewanie i wentylację do różnicy temperatury powietrza wewnętrznego i powietrza zewnętrznego, pomijając bezwładność cieplną przegród budowlanych. W przedstawionym artykule przeprowadzono analizę wpływu bezwładności cieplnej przegród na zmienność obciążeń cieplnych w roku, porównując ją z dotychczas stosowanym wykresem obciążeń. Do wyznaczenia bezwładności cieplnej wykorzystano opracowaną wcześniej metodologię obliczeń. W efekcie wykazano znaczną różnicę pomiędzy teoretycznym i rzeczywistym przebiegiem wykresu obciążeń cieplnych. Wyniki potwierdzono przykładami zmian zużycia ciepła w rzeczywistych obiektach budowlanych.
EN
A specific feature of district heating systems is the fact that the heat load of the system is highly variable through the year. The heat load diagram is used to analyze this variability with multiple applications. The basis for the preparation of the load diagram is the variability of the outside air temperature, characteristic for the location of the object for which the diagram is prepared. The methodology of drawing up the diagram assumes that the heat loss for heating and ventilation is proportional to the temperature difference between internal and external air at any time, ignoring the thermal inertia of building partitions. In the presented article, an analysis of the influence of thermal inertia of partitions on the thermal loads’ variability during a year was carried out, in comparison with the load diagram used so far. The calculation methodology developed earlier was used to determine the thermal inertia. As a result, a significant difference was demonstrated between the theoretical and real course of the thermal load diagram. The results were confirmed by examples of changes in heat consumption in real buildings.
EN
Aim: An extremely important property of firefighters’ special clothing is thermal resistance of the clothing materials to heat transfer from radiation or flame. Performing tests with the use of thermal mannequins may contribute to the improvement of clothing sets, as such tests indicate weak points of the tested products. The review article presents information on the testing of special clothing on mannequins and a short history of test stands with the use of thermal mannequins. Introduction: Using innovative techniques and technologies provides firefighters-rescuers with an appropriate level of safety. Special clothing is a barrier between the human body and the heat and water vapour from the environment. It is this garment that protects the human body from overheating or cooling down. Methodology: The general test procedure for using thermal mannequins is described in ASTM standards (for instance ASTM F2370 – 10 [1], ASTM F2371 – 10 [2]). Testing of special clothing allowing for an accurate assessment of the degree of protection of the human body against the effects of fire, flame and heat was initiated in the United States. The assumption of these works was to create a mannequin for testing the resistance of clothing equipped with heat sensors to flash fires. Currently, there are around 100 different models of thermal mannequins around the world. Technological progress in the post-war period resulted in the rapid development of mannequins built with a multi-segment structure. This allowed to increase the accuracy of the measurements that simulated heat exchange between the human body and the environment. The data obtained in this manner is repeatable, which allows for standardization of the test requirements for thermal insulation of clothing sets. Conclusions: Performing tests using thermal mannequins contributes to the improvement of clothing sets in order to increase the safety of the users. The results obtained under the test conditions very accurately indicate the number, location and degree of burns to which the user of such clothing may be exposed.
PL
Cel: Niezwykle ważną właściwością strażackich ubrań specjalnych jest odporność termiczna materiałów odzieżowych na przenikanie ciepła pochodzącego z promieniowania lub płomienia. Wykonywanie badań przy użyciu manekinów termicznych może przyczynić się do udoskonalania zestawów odzieżowych, bowiem badania takie wskazują słabe punkty testowanych wyrobów. W artykule mającym charakter przeglądowy przedstawiono informacje na temat prowadzonych badań ubrań specjalnych na manekinach oraz krótką historię stanowisk badawczych z wykorzystaniem manekinów termicznych. Wprowadzenie: Zastosowanie innowacyjnych technik i technologii zapewnia strażakom-ratownikom odpowiedni stopień bezpieczeństwa. Odzież specjalna stanowi barierę pomiędzy ludzkim ciałem a ciepłem i parą wodną pochodzącymi ze środowiska. To właśnie ubranie ma za zadanie chronić ciało człowieka przed nadmiernym przegrzaniem lub wychłodzeniem. Metodologia: Ogólna procedura postępowania badawczego z wykorzystaniem manekinów termicznych opisana jest w standardach ASTM (np. ASTM F2370 – 10 [1], ASTM F2371 – 10 [2]). Badania odzieży specjalnej pozwalające na dokładną ocenę stopnia ochrony ludzkiego ciała przed działaniem ognia, płomienia i ciepła zapoczątkowano w Stanach Zjednoczonych. Założeniem wspomnianych prac było stworzenie manekina do badania odporności odzieży na działanie pożarów błyskawicznych, wyposażonego w czujniki ciepła. Obecnie na świecie funkcjonuje ok. 100 różnych modeli manekinów termicznych. Postęp technologiczny w okresie powojennym spowodował szybki rozwój budowanych manekinów, które posiadały wielosegmentową budowę. Pozwoliło to na zwiększenie dokładności wykonywanych pomiarów symulujących wymianę ciepła między organizmem ludzkim a otoczeniem. Uzyskane w ten sposób dane są powtarzalne, co pozwala na znormalizowanie wymagań badawczych izolacyjności cieplnej zestawów odzieżowych. Wnioski: Wykonywanie badań przy użyciu manekinów termicznych przyczynia się do udoskonalania zestawów odzieżowych, aby zwiększać bezpieczeństwo użytkowników. Uzyskane w warunkach badawczych wyniki w bardzo dokładny sposób wskazują liczbę, lokalizację i stopień oparzeń, na jakie może być narażony użytkownik takiego ubrania.
PL
Ocena najwyższego dopuszczalnego obciążenia cieplnego organizmu w środowisku gorącym wyznaczana jest za pomocą wskaźnika WBGT. Nazwa wskaźnika WBGT pochodzi od nazw czujników wykorzystywanych do pomiarów przesiewowych parametrów środowiska: do pomiaru temperatury w stanie wilgotnym (temperatura wilgotnego termometru – Wet Bulb) oraz pomiaru temperatury poczernionej kuli (Globe Temperature). WBGT jako wskaźnik używany do oceny obciążenia cieplnego organizmu do 2017 r. był powiązany z wydatkiem energetycznym i przedstawiony w postaci tabel w polskim wydaniu normy PN-EN 27243:2005 (oraz PN-EN 27243:2005P). W 2017 r. normę zastąpiono dokumentem EN ISO 7243:2017, a w styczniu 2018 r. zostało zatwierdzone polskie tłumaczenie normy PN-EN ISO 7243:2018-01. W artykule zamieszczono opis metodyki prowadzenia badań wskaźnika WBGT zgodnie z zapisami PN-EN ISO 7243:2018-01. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
EN
The assessment of maximum allowable heat load of a body in a hot environment is determined using the WBGT index. The name of the WBGT index is derived from the measurement of two parameters: natural wet-bulb temperature and black globe temperature. WBGT as an indicator used to assess the heat load (until 2017) was related to the metabolic heat production and placed in the form of tables in the Polish edition of Standard No. PN-EN 27243:2005 (and PN-EN 27243:2005P). In 2017, this standard was replaced by Standard No. EN ISO 7243:2017, and in January 2018, the Polish translation of Standard No. PN-EN ISO 7243:2018-01 was approved. This article describes the methodology of conducting WBGT research according to Standard No. PN-EN ISO 7243:2018-01. This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
PL
Norma PN-EN ISO 52016-1 zastąpiła wycofaną normę PN-EN ISO 13790. Opisuje ona szereg metod obliczeniowych pozwalających wyznaczyć zapotrzebowanie na energię użytkową budynków do ich ogrzewania, chłodzenia, nawilżania i osuszania powietrza wewnętrznego, obliczania zmiennej w czasie temperatury wewnętrznej w budynkach oraz wyznaczania obciążenia cieplnego ogrzewania i chłodzenia w budynkach. W artykule o charakterze przeglądowym opisano ogólnie metody obliczeniowe zawarte w tej normie i omówiono jej związki z normą PN-EN ISO 52017 oraz innymi powołanymi normami. Przedstawiono również różnice w metodach obliczeniowych wycofanej normy PN-EN ISO 13790 i zastępującej ją PN-EN ISO 52016-1 oraz ich wpływ na system świadectw energetycznych w Polsce i metody obliczeń auditingu energetycznego.
PL
W Polsce jest stosunkowo niewiele budowli o charakterze zabytkowym, które są w dobrym stanie technicznym. Większość z nich wymaga częściowej lub całkowitej termomodernizacji, którą należy przeprowadzić tak, by w możliwie największym stopniu zachować ich historyczne walory. Stąd wynikają różnorakie ograniczenia dotyczące doboru materiałów i technologii wykonania, które ze względu na swoją specyfikę są zawsze droższe niż w innych obiektach. W artykule, na przykładzie domu klasztornego Sióstr Bernardynek w Św. Katarzynie k/Kielc, omówiono równoważenie kosztów inwestycyjnych oszczędnościami na ogrzewanie przy różnych parametrach kredytowania. Na podstawie cen roku 2018 obliczono optymalną grubość izolacji przegród ciepłochronnym tynkiem na bazie perlitu ułożonym od wewnątrz. Przy trzyletnim okresie kredytowania i stałej stopie procentowej 8% optymalna grubość izolacji wynosi 3,6 cm przy całkowitym koszcie termomodernizacji ściany kaplicy równym 112,53 zł/m2, a wykonanie dwóch warstw o całkowitej grubości 6 cm zwiększa koszty tylko do około 120 zł/m2, co powoduje ponad 25% obniżenie strat ciepła przez przenikanie. Wskazano również, że wraz z wydłużeniem okresu kredytowania inwestycji, korzystnie rośnie wielkość optymalnej grubości izolacji. Natomiast wpływ wielkości stopy oprocentowania jest stosunkowo niewielki. Na przykładzie kaplicy klasztornej omówiono również efekty rozłożenia procesu termomodernizacji na etapy.
EN
There are relatively few historic buildings in Poland that would be in good technical condition. Most of them require partial or complete thermal modernization, which should be carried out so as to preserve their historical values as much as possible. Hence, there are various restrictions on the choice of materials and production technology, which are always more expensive due to their specificity. Here, on the example of the monastery house of the Bernardine Sisters of St. Katarzyna near Kielce, the benefits of balancing the costs and benefits of investments based on cost accounting were shown. Based on the prices of 2018, the optimal insulation thickness was calculated for heat-insulated perlite plaster from the inside. With a three-year loan period and a constant interest rate of 8%, the optimal insulation thickness is 3.6 cm with a total cost of thermo- modernization of the chapel wall equal to 112.53 PLN/m2, and the implementation of two layers with a total thickness of 6 cm increases costs to only about 120 PLN/m2, however, this results in a more than 25% reduction of heat transfer through the partition. It was also pointed out that as the investment loan period was extended, the optimum insulation thickness increases favorably. However, the impact of the interest rate is relatively small. The effects of spreading the thermomodernization process on stages were discussed on the example of the monastery chapel.
PL
Praca dotyczy natryskiwanej plazmowo powłoki NiCrFeSi na podłoże ze stali kotłowej (P 250GH). Powłokę obciążano cieplnie w atmosferze powietrza i w środowisku siarki. Obciążenie cieplne wynosiło 2000 cykli. Jeden cykl obejmował: nagrzewanie do temperatury 560 °C i wygrzewanie w tej temperaturze w czasie 3 minut, chłodzenie do temperatury 300 °C, nagrzewanie do 560 °C i wygrzewanie w tej temperaturze w czasie 1,5 minuty oraz chłodzenie do temperatury 150 °C. Efektem obciążeń cieplnych było zmniejszenie grubości powłoki o 39 μm. Stwierdzono, że siarka dyfundowała w warstwę przypowierzchniową. Tworzące się produkty jej reakcji z niklem i chromem sprzyjały wykruszaniu się składników tej warstwy, które następnie ulegały utlenianiu.
EN
The paper deals with a NiCrFeSi coating plasma-sprayed on a boiler steel (P 250GH) substrate. The coating was heat-loaded in atmosphere of air and in sulfur environment. The heat load comprised 2000 cycles, whereas each of the cycles included: heating up to 560 °C and soaking at the temperature for 3 minutes; cooling down to 300 °C and soaking at the temperature for 1.5 minutes; and cooling down to 150 °C. As a result of such thermal cycling, thickness of the coating was reduced by 39 μm. It has been found that sulfur had diffused into the superficial layer. The occurring products of sulfur reacting with chromium and nickel contributed to spalling of components of the layer which subsequently were subject to oxidation.
11
Content available remote Obciążenia termiczne w eksploatowanym żelbetowym kominie przemysłowym
PL
W artykule opisano oddziaływania termiczne w eksploatowanym kominie Elektrociepłowni Białystok, z uwzględnieniem warunków klimatycznych i parametrów technicznych związanych z odprowadzaniem spalin z kotłów energetycznych. Rozpatrzono przypadki obciążenia temperaturą, jakie mogą wystąpić w okresie zimowym i letnim podczas eksploatacji komina przemysłowego.
EN
In the article there were determined the impact of the thermal in the operated chimney Combined Heat and Power Plant Bialystok, taking into account the climatic conditions and technical specifications related to the evacuation of flue gas from boilers. Temperature load cases that may occur in the winter and summer during operation of the chimney were also taken under consideration.
13
PL
W metodologii obliczania charakterystyki energetycznej budynku obowiązującej w Polsce nie jest uwzględniane ograniczenie energii końcowej na ogrzewanie budynku wynikające z mocy źródła ciepła. W artykule zaproponowano sposób uwzględnienia tego ograniczenia, polegający na obliczaniu w każdym miesiącu sezonu grzewczego podaży energii końcowej ze źródła ciepła i zapotrzebowania na tę energię obliczanego według stosowanej dotychczas metody. Do określenia charakterystyki energetycznej powinna być przyjmowana mniejsza z tych dwu wartości. Wykazano, że nieuwzględnianie mocy źródła ciepła w przypadku oceny energetycznej budynków wzniesionych przed transformacją ustrojową w Polsce, w stanie przed termomodernizacją prowadzi do znacznego zawyżenia potrzeb energetycznych budynku. Omówiono również konsekwencje znacznej nadwyżki mocy cieplnej źródła, w stosunku do obciążenia cieplnego budynku, często występujące w budynkach, w których prace termomodernizacyjne rozpoczęto od systemu grzewczego.
EN
In the methodology of energy performance of buildings in force in Poland, the final energy limit for heating a building resulting from the heat source’s power is not taken into account. The article proposes a way to take into account this limitation, consisting in calculating for each month of heating season the final energy supply from the heat source and the demand for this energy calculated according to the method used so far. To determine the energy performance should be taken the smaller of these two values. It has been shown that the failure to take into account the power of the heat source in the case of energy assessment of buildings erected before the political transformation in Poland, in the state before thermal retrofitting leads to a significant over-estimation of the energy needs of the building. Also were discussed the consequences of a significant surplus of thermal power of the source, in relation to the heat load of the building, often occurring in buildings in which thermo-modernization works started from the heating system.
PL
Do podstawowych zagrożeń, związanych z pracą ratownika górniczego poza zagrożeniem wybuchem metanu, należą wysoka temperatura i wilgotność powietrza otoczenia, duża masa przenoszonego sprzętu. W artykule przedstawiono wyniki badań przeprowadzonych w warunkach laboratoryjnych dla dwóch wariantów stosowanego przez ratowników ubioru, aparatu ratowniczego i dwóch poziomów temperatury otoczenia. Porównano czas trwania badań do osiągnięcia limitów fizjologicznych temperatury wewnętrznej, częstości skurczów serca, bądź zakończenia badań z powodów subiektywnych. Przedstawiono różnice w intensywności pocenia, gromadzenia potu w odzieży, akumulacji ciepła i subiektywnych ocen wrażeń cielnych przy dwóch poziomach temperatury otoczenia.
EN
High levels of air temperature and humidity, the large mass of the transferred equipment are basic risks beyond the risk of explosion of methane of work-related mining rescuers. The article presents results of a research study conducted in the laboratory for two variants of clothing developed for mining rescuers and one kind of respiratory protective device at two levels of ambient temperature and moderate physical work intensity. A duration of the exercise to achieve the physiological limits of the internal temperature, heart rate or completion of the study because of subjective reasons was compared between studies conducted at two levels of air temperature. Differences in the intensity of sweating, level of sweat accumulated in clothing, heat accumulation and subjective ratings of the thermal state at mentioned variants of environment conditions were also described.
15
Content available Obciążenia podłóg przemysłowych
PL
Podłogi przemysłowe mają bardzo różne przeznaczenie, dlatego powinny spełniać specjalne wymagania. Płyta nośna musi przenosić duże obciążenia skupione i powierzchniowe pochodzące od ciężkich maszyn, składowanych produktów i poruszających się po niej pojazdów. Oprócz tych obciążeń, w trakcie produkcji, na posadzkę mogą oddziaływać maszyny pracujące dynamicznie, obciążenia od temperatury i skurczu betonu. Wszystkie te obciążenia muszą zostać przejęte bez deformacji, osiadań i zarysowania.
EN
Industrial floors are intended for many different uses, therefore they should meet special requirements. The load plate must carry significant concentrated and surface loads deriving from heavy machinery, stored products and moving vehicles. Apart from these loads, during manufacturing, the flooring may be affected by dynamically working machines, loads resulting from temperature and concrete shrinkage. All these loads need to be carried without deformations, sinking and scratches.
PL
W artykule omówione zostały sposoby określenia obciążenia cieplnego i mechanicznego silnika okrętowego pracującego w normalnych warunkach oraz z wybranymi niesprawnościami. Badanie polegało na pomiarze parametrów pracy silnika z symulowaną uszkodzoną turbosprężarką oraz symulowaną nieszczelną pompą wtryskową i porównanie ich do parametrów pracy silnika technicznie sprawnego. Badania zostały przeprowadzone w warunkach laboratoryjnych na silniku SULZER 3AL25/30.
EN
The article explains how to determine the thermal and mechanical loads on the marine engine working with normal operating conditions and with selected technical failures. The survey has been based on comparison between the parameters of the engine operating with simulated damaged turbocharger and leaking simulated injection pump, and the engine working in a proper technical condition. The research has been conducted SULZER 3AL25/30 engine, under laboratory conditions
PL
W pracy przedstawiono wyniki badań i analiz zużycia energii w wolnostojącej szklarni z ekranem termoizolacyjnym. Celem tych badań była analiza zmienności obciążenia cieplnego w szklarni z ruchomym ekranem termoizolacyjnym. Analizy wykonano w oparciu o pomiary parametrów klimatu, mikroklimatu szklarni, zużycia energii oraz parametrów opisujących funkcjonowanie wyposażenia technicznego szklarni. Według analiz średni miesięczny współczynnik obciążenia zawiera się w zakresie od 9% do 69%. Przedstawiono miesięczną i dobową strukturę zużycia energii w badanej szklarni z ekranem i bez ekranu. W analizach zmienności obciążenia cieplnego systemu grzewczego szklarni z ekranem termoizolacyjnym zaleca się korzystać z danych zużycia energii lub zapotrzebowania na ciepło.
EN
This paper presents results of investigation of the free-standing greenhouse with movable thermal screen inside. Energy consumption by the modern greenhouse object is analyzed, basing on the in-situ measurements. The aim of these investigation was analysis variability of heating load in greenhouse with thermal screen. The analysis was based on the registration of the external climate parameters, greenhouse microclimate, energy consumption and parameters describing the functioning of the technical equipment of greenhouse. The computations show that the mean monthly Load Factor is in the range from 9% in June to 69% in January. Shows the structure of energy consumption per month with regard to the functioning of the greenhouse with and without a thermal screen as well as its profile changes in cross daily. In analyzes of variability heating load in greenhouse with additional cover it is recommended to use the data about energy consumption or heat demand.
PL
Przeanalizowano wpływ lokalizacji budynku usytuowanego w danej strefie klimatycznej na wartość wskaźnika rocznego zapotrzebowania na nieodnawialną energię pierwotną do ogrzewania i wentylacji EPH oraz na projektowe obciążenie cieplne budynku ΦHL. Analizę przeprowadzono na przykładzie budynku wielorodzinnego bez instalacji chłodniczej w dwóch wariantach. Pierwszy - budynek spełniający wymagania w zakresie izolacyjności przegród budowlanych obowiązujące od 2017 r. i drugi - od 2021 r. Obliczenia wykonano w odniesieniu do pięciu stref klimatycznych w Polsce, wybierając w danej strefie dwie stacje meteorologiczne tj. najwyższej i najniższej liczbie stopniodni. Z analizy wynika, że różnice pomiędzy uzyskanymi wartościami EPH+W wynoszą od 27,4% do 36,5% w zależności od liczby stopniodni i współczynnika nakładu nieodnawialnej energii pierwotnej, wartość ΦHL natomiast różniła się od 5,4% do 22,1% w zależności od zewnętrznej temperatury obliczeniowej. Przepisy krajowe w zakresie współczynnika przenikania ciepła przegród budowlanych oraz wskaźnika EPH+W budynku są takie same bez względu na jego lokalizację (po uwzględnieniu potrzeb do przygotowania ciepłej wody i energii pomocniczej EPH+W).
EN
The paper analyses location influence of a building in a climate zone on the value of annual demand indicator for non-renewable primary energy for heating and ventilation EPH, including the design thermal load of the building ΦHL. The analysis was conducted on the example of a multi-family building with no cooling system in two variants. The first - a building that meets the requirements being in force since 2017 for insulation of building partitions. And the second variant since 2021. Calculations have been made in relation to the five climatic zones in Poland, selecting two meteorological stations in the zone, i.e. the highest and lowest number of degree days. The analysis shows that the differences between the EPH+W values obtained range from 27.4% to 36.5%, depending on the number of degree days and on the non-renewable primary energy demand indicator, while the value of ΦHL range from 5.4% to 22.1% depending on the calculated external temperature. The national legislations in the field of thermal transmittance coefficient of building partitions and the ratio of EPH+W in the building are the same regardless of its location (taking into account the needs for hot water preparation and auxiliary energy EPH+W).
EN
The paper presents the results of numerical computations performed for the furnace chamber waterwalls of a supercritical boiler with a steam output of 2400 x 10[3] kg/h. A model of distributed parameters is proposed for the waterwall operation simulation. It is based on the solution of equations describing the mass, momentum and energy conservation laws. The aim of the calculations was to determine the distribution of enthalpy, mass flow and fluid pressure in tubes. The balance equations can be brought to a form where on the left-hand side space derivatives, and on the right-hand side – time derivatives are obtained. The time derivatives on the right-hand side were replaced with backward difference quotients. This system of ordinary differential equations was solved using the Runge-Kutta method. The calculation also takes account of the variable thermal load of the chamber along its height. This thermal load distribution is known from the calculations of the heat exchange in the combustion chamber. The calculations were carried out with the zone method.
20
Content available Analiza termiczna żelbetowych kominów
PL
W pracy przedstawiono analizę numeryczną modeli komina żelbetowego. Modele uwzględniały degradację stanu technicznego w postaci zmiany wytrzymałości betonu i grubości ścianek żelbetowego płaszcza w kolejnych segmentach. Obciążenie konstrukcji stanowi zmienne pole temperatur spowodowane warunkami klimatycznymi. Obciążenie to przyłożone zostało do analizowanych modeli jako gradienty temperatur pomiędzy wewnętrzną i zewnętrzną stroną płaszcza. Uwzględniono wpływ promieniowania słonecznego absorbowanego przez beton na temperaturę płaszcza komina. Wyznaczono naprężenia pionowe i rozwarcie rys w analizowanych modelach.
EN
The paper presents a numerical analysis of reinforced concrete chimney models. The models take into account changes in the strength of concrete and coat thickness in the segments. Design load is variable temperature field due to climatic conditions. This load was applied as the temperature gradients between the inner and the outer side of the shell. The impact of solar radiation absorbed by the concrete coat is also analyzed. Vertical stresses and the cracks are calculated in the analyzed models.