Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  nonwoven geotextiles
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Nonwoven geotextile filters have been used in geo-environmental engineering for decades to prevent the movement of base soil fine particles, allowing adequate seepage to flow through the geotextile plane. Most of the design criteria developed for nonwoven geotextiles are based only on the comparison between their characteristic opening size and the indicative diameter of the soil to be filtered. In the meantime, the nonwoven geotextile fibrous structure has an influence on the filtration of the soil-geotextile system. In this paper the numbers of constrictions of nonwoven geotextile samples were determined to verify the existence of a correlation between the geotextile structure and the filtration behaviour of soil-geotextile systems. The compatibility between an internally unstable soil and a nonwoven geotextile filter was evaluated using the gradient ratio test. The results obtained can also be the basis for modifying the geotextile filter design and selection criteria.
PL
Spośród różnych materiałów geosyntetycznych, szerokie zastosowanie w systemach filtracyjnych i drenażowych znalazły geowłókniny. Zapobiegają one mieszaniu się materiałów o różnym uziarnieniu umożliwiając jednocześnie swobodny przepływ wody w kierunku prostopadłym do płaszczyzny wyrobu. Dla celów prawidłowego funkcjonowania instalacji odwadniających projektowanie geowłóknin pełniących funkcje filtracyjne sprowadza się do spełnienia trzech podstawowych kryteriów: zatrzymywania cząstek, przepuszczalności oraz odporności na kolmatację. Kryteria te głównie opierają się na porównaniu charakterystycznej wielkości porów geowłókniny z określonymi średnicami zastępczymi gruntu chronionego oraz przepuszczalności geowłókniny w kierunku prostopadłym do płaszczyzny wyrobu ze współczynnikiem filtracji gruntu. Okazuje się jednak, że także struktura geowłókniny ma wpływ na jej właściwości filtracyjne. W prezentacji zostaną przedstawione wyniki badań współczynnika proporcjonalności spadku (GR) geowłóknin o różnej liczbie przewężeń (number of constrictions) zależnej od grubości, porowatości i średnicy pojedynczego włókna materiału, w celu określenia wpływu struktury geowłókniny na jej podatność na proces kolmatacji mechanicznej.
EN
Nonwoven geotextiles are often used in road construction as a separation layer. They consist of the web of fibers with different orientations. The orientation of fibers has an important influence on physical and mechanical properties of nonwoven geotextiles. The production of nonwoven geotextiles is cheaper in comparison to woven or knitted fabrics which can also be used as separation geotextiles. The purpose of this research was to study the influence of structural properties of nonwoven geotextiles, namely the diameter of fibers and mass and thickness of nonwoven geotextiles, on their mechanical and hydraulic properties. Six types of nonwoven geotextiles were used in the research. They were produced by the drylaid process (carded) using mechanical bonding technique and also with the combination of mechanical and thermal bonding technique. The research confirmed that the bonding technique and structural properties significantly influence the separation and filtration properties of nonwoven geotextiles, such as opening size and water permeability. It was also found that there are no significant differences in mechanical properties, such as viscoelastic properties and compression creep, between the samples in the dry and wet conditions.
PL
Celem badań było określenie wytrzymałości na ścinanie mieszaniny popiołowożużlowej ze składowiska odpadów Elektrociepłowni Kraków (EDF Polska S.A.) oraz oporu tarcia międzyfazowego na kontakcie pomiędzy przedmiotową mieszaniną a geowłókniną PPST 100. Badania przeprowadzono w aparacie bezpośredniego ścinania. Próbki do badań formowano w skrzynce aparatu przy wilgotności optymalnej przez ich zagęszczanie do IS = 0,90 i 1,00. Ścinanie próbek przeprowadzono bez i z ich nawodnieniem. Parametry wytrzymałości na ścinanie mieszaniny popiołowo-żużlowej były duże. Stwierdzono istotny wpływ zagęszczenia, którego wzrost spowodował zwiększenie kąta tarcia wewnętrznego i spójności. Natomiast nawodnienie próbek spowodowało zmniejszenie parametrów wytrzymałości na ścinanie. Wartości parametrów oporu tarcia międzyfazowego na kontakcie mieszanina popiołowo-żużlowa a geowłóknina były również duże. Należy również wskazać, że nawodnienie próbek spowodowało zwiększenie kąta tarcia międzyfazowego i zmniejszenie adhezji. Można więc stwierdzić, że stosowanie mieszanin popiołowo-żużlowych jako kruszywa antropogenicznego jest ważnym i istotnym zagadnieniem w aspekcie ochrony naturalnych materiałów gruntowych.
EN
The tests aimed at the determination of the shear strength of the ash-slag mixture from the landfill of the Combined Heat and Power Plant „Kraków” S.A. (EDF Polska S.A.) as well as the interphase friction resistance at the contact between the mixture in question and the PPST 100 114 A. Gruchot, E. Zawisza, E. Czyż geotextile. The tests were conducted in a direct shear apparatus. Samples for the tests were formed in the apparatus box at the optimum moisture content by compacting them to IS = 0.90 and 1.00. Shearing of the samples was carried out without and with their saturation. The shear strength parameters of the ash-slag mixture were large. It was stated the significant influence of the compaction, the growth of which has resulted in an increase in the angle of internal friction and cohesion. Whereas the saturation of the samples reduced the shear strength parameters. The values of the interphase friction resistance at the contact: the ash-slag mixture and the geotextile were large as well. It should also be noted that the saturation of the samples increased the angle of interphase friction and decreased the adhesion. It can be concluded that the use of the ash-slag mixtures as anthropogenic aggregates is an important issue in terms of protection of natural soil materials.
PL
Zagadnienia filtracji oraz problem kolmatacji geosyntetyków są niezwykle ważne przy projektowaniu systemów drenażowych wód czystych, a szczególnie odcieków ze składowisk odpadów. W artykule przedstawiono wyniki badań wodoprzepuszczalności geowłókniny w kierunku prostopadłym do powierzchni wyrobu metodą stałej wysokości naporu hydraulicznego przeprowadzone zgodnie z metodyką podaną w normie PN ISO 11058:2010. Badania przeprowadzono dla próbek geowłókniny „eksploatowanej” pobranych ze składowiska odpadów Radiowo po 12 latach od wbudowania oraz dla próbek tej samej geowłókniny „czystej”. Opisano metodykę badań i przeanalizowano wpływ zakolmatowania geowłókniny na charakterystyki wodoprzepuszczalności i wielkości współczynników przepuszczalności poprzecznej przy spadku wysokości naporu hydraulicznego, wynoszącym 50 mm.
EN
The filtration and clogging problems are very important in clear water and especially leachate drainage systems. The paper presents the laboratory results of water permeability in the normal direction to the plane, of exploited and unexploited non-woven geotextile samples collected from the Radiowo sanitary landfill. The studies design and analysis described, have determined the velocity index and permeability coefficient at a head loss of 50 mm for the tested non-woven geotextile. Moreover, within the paper the influence of non-woven geotextile clogging on the water permeability was assessed.
EN
An analysis of the basic properties of geotextiles obtained by two-sided needle punching and by two-layered needle punching on the fabric underlay is presented in this paper. The influence of geotextile production technology on their functional properties was evaluated, the parameters of geotextiles manufactured from staple fibres by mechanical needle punching were compared for both techniques, and the influence of the mass per unit area on the mechanical and hydraulic properties is shown. It was found that geotextiles obtained by two-sided needle punching had very good hydraulic properties thanks to their spatial structure, whereas geotextiles obtained by two-layered needle punching on the fabric underlay, apart from good hydraulic properties, had very good tensile strength and small elongation at a maximum load, which is particularly useful for reinforcement.
PL
W pracy zaprezentowano analizę podstawowych właściwości geowłóknin otrzymanych techniką igłowania mechanicznego dwustronnego i techniką igłowania dwuwarstwowego na podkładzie tkaninowym. Dokonano oceny wpływu techniki wytwarzania geowłóknin na ich właściwości użytkowe, porównano parametry geowłóknin wytwarzanych z włókien odcinkowych w procesie igłowania mechanicznego dla obu technik, zobrazowano wpływ masy powierzchniowej na właściwości mechaniczne i hydrauliczne geowłóknin. Stwierdzono, że geowłókniny wytwarzane metodą dwustronnego igłowania wykazują bardzo dobre właściwości hydrauliczne, natomiast geowłókniny wytwarzane na podkładzie tkaninowym, obok właściwości hydraulicznych charakteryzują się bardzo dobrymi właściwościami wytrzymałościowymi, szczególnie przydatnymi dla funkcji zbrojeniowej.
6
Content available remote Ocena przydatności geowłóknin do ochrony gruntu przed kolmatacją
EN
Use of natural waters which include organic and mineral suspended matter, suspensions, bacteria, microorganisms for infiltration facilities supply contributes to clogging of pores in the interior of the filtering medium as well as to formation of clogging mat at the infiltration surface. Consequences of silting-up enforce using solution designed to regeneration filtration ability of ground. One of methods using in order to devices protection from deep clogging are nonvowen geotextiles. This paper presents the research results indicating effectiveness of nonvowen geotextiles as layer which separate clogged mat from filtering medium.
PL
Omówiono badania nad cechami fizycznymi (masa powierzchniowa i grubość pod obciążeniem) oraz wytrzymałościowymi (rozciąganie metodą szerokich próbek i opór na przebicie metodą CBR), wykonane na fabrycznie nowych próbkach czterech geowłóknin oraz próbkach odzyskanych z nasypu. Przedstawiono szczegółową analizę zmian parametrów geowłóknin na skutek wbudowania w konstrukcję ziemną.
EN
In this paper tests of physical and mechanical parameters of non-woven geotextiles, which performed function of protection and separation in earth structures, are presented. The tests of mass per unit area, thickness under loads, tensile strength by wide-width method and static puncture resistance by CBR method were performed for four non-woven geotextile products, for standard samples and samples extracted from the road embankment. Changes of physical and mechanical parameters of non-woven geotextiles as a result of installation in embankment are discussed in details.
8
Content available remote Zmiana współczynnika filtracji układu piasek średni-geowłóknina K 500
EN
The paper presents the results of laboratory tests carried out in the modified soil-geotextile permeametr (Fig. 1) recommended in ASTM standard D 5101-90. Laboratory tests were performed on nonwoven geotextile K-500 (Tab. 1) and medium sand (Tab. 2). In ftgures 2 and 3 the change in permeability coefficient in soil-geotextile system and soil under different hydraulic gradients are shown. The relationship for the evaluation of the change in coefficient in soil-geotextile system based on the initial values of the permeability coefficient of geotextile and soil as well as hydraulic gradient is proposed.
9
Content available remote Wpływ kolmatacji na współczynnik filtracji układu grunt-geowłóknina
EN
The paper presents the results of laboratory tests carried out in the modified soiI-geotextile penneameter (Fig. 1) recommended in ASTM standard D 5101-90. Laboratory tests were performed on nonwoven geotextile K-500 (Tab. 1) and slightly clayey sand (Tab. 2). In figures 2 and 3 the change in permeability coefficient in soil-geotextile system for individual zones under different hydraulic gradients are shown. The changes in permeability coefficient in soil-geotextile system are caused by phenomena mechanical (Fig. 4), biological (Fig. 5 and 6 ) and chemical clogging.
PL
W niniejszym artykule przedstawiono procedurę badawczą oraz analizę wyników badań odporności na przebicie materiałów geosyntetycznych, które umieszczono na piankach poliuretanowych charakteryzowanych przez wskaźnik podatności. CBR. Badania przeprowadzono stosując procedury normy PN-EN ISO 12236 oraz normy PrEN 189066 (Załącznik A).
EN
The paper presents the procedure of the test puncture resistance of supported geosynthetics as well as results of analysis carried out according to in PN-EN ISO 12236 and Pr EN 189066 (Annex A).
11
Content available remote Zmiana współczynnika filtracji w układzie grunt-geowłóknina
EN
The paper presents the results of laboratory tests carried out in the modified soil-geotextile permeameter (Fig. 1) recommended in AST Mstandard D 5101-90. Laboratory tests were performed on nonwoven geotextile K-500 (Tab. 1) and clayey sand (Tab. 2). In Figures 2 and 3 the change in permeability coefficient in soil-geotextile system and soil under different hydraulic gradients are shown. The relationship for the evaluation of the change in permeability coefficient in soil-geotextile system based on the initial values of the permeability coefficient of geotextile and soil as well as hydraulic gradient is proposed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.