Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  non-linear dynamic analysis
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of this paper is to analyze the possibility to improve the seismic performance of cross-laminated timber (CLT) panel buildings introducing in the structure dissipative connectors in substitution of the classical hold-downs. In fact, as demonstrated by past experimental tests and numerical analyses, hold-downs exhibit a limited dissipation capacity. The proposed dissipative connector is called XL-stub and applies the concept usually adopted for ADAS devices. In order to prove the effectiveness of the proposed system the results of an experimental program devoted to characterize the force–displacement response under cyclic loads and low fatigue behavior of the XL-stub are presented and compared to the results of cyclic tests of hold-downs with same resistance. Afterwards, the comparison is extended at the level of the building, evaluating the influence of the connection on the seismic performance of the whole CLT panel building. To this scope, a FE model of the three-storey building tested within the SOFIE project is calibrated and multiple transient dynamic analyses are performed both for the building with the classical layout of connections and for the building equipped with XL-stubs. The obtained results are compared and the values of the behavior factor for the two solutions are calculated.
2
Content available remote Modelling of concrete buildings for practical nonlinear seismic response analysis
EN
Member modelling for the practical evaluation of the seismic performance of real concrete buildings on the basis of nonlinear dynamic analysis in 3D is overviewed. Fibre Element modelling is highlighted and contrasted to simplified lumped inelasticity models of members, with parameters fitted to a wealth of cyclic test results. An application to a full-scale 3-storey structure in 3D subjected to seismic testing under two horizontal components of ground motion validates this latter type of modelling. Two further applications are presented, one to explain the partial collapse of a multi-storey building in the Athens (1999) earthquake and another for the seismic assessment and retrofitting of a theatre building. The applications, which demonstrate simple lumped inelasticity member models, with parameters fitted to test results, are cost-effective and reliable alternatives to prohibitive Fibre Element modelling.
PL
W artykule przedstawiono modelowanie (na bazie nieliniowej analizy dynamicznej w 3D) elementów rzeczywistych budynków betonowych, służące do praktycznej oceny wpływu oddziaływań sejsmicznych. Wyróżniono modelowanie elementami pasmowymi, w odróżnieniu od uproszczonych niesprężystych modeli skupionych elementów z parametrami dopasowanymi do dużej ilości wyników badań cyklicznych. Wykonanie trójwymiarowego, naturalnej wielkości modelu 3-kondygnacyjnej konstrukcji poddanej obciążeniu sejsmicznemu, w postaci dwóch poziomych składowych ruchu gruntu, uzasadnia zastosowanie tego drugiego typu modelowania. Przedstawiono również dwa dalsze zastosowania, pierwsze do wyjaśnienia częściowego zawalenia się wielokondygnacyjnego budynku w wyniku trzęsienia ziemi w Atenach (1999) i drugie do oceny sejsmicznej i modernizacji budynku teatru. Przedstawione zastosowania dowodzą, że proste, niesprężyste modele skupione, z parametrami dostosowanymi do wyników badań są ekonomicznie efektywne i stanowią pewną alternatywę dla modelowania elementami pasmowymi.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.