Materials and semi-manufactured products for aviation equipment are usually subjected to increasingly rigorous demands for the quality control. In many cases, like hardened or carburized wheels or rollers assembled in the gear motors, the control procedures enforce necessity of the selective testing of details coming from production lines using destructive techniques. The main aim of diagnostic investigations carrying out on series of final products is to assess qualitatively and quantitatively the layers obtained due to carburizing and induction hardening. Unfortunately, such processes increase the fabrication costs significantly, especially in the case of complex manufacturing technology applied and small-lot production as well. In order to reduce them the attempts for application of non-destructive testing methods are taken for evaluation of either the layers quality or the products subjected to surface treatments. This paper presents the eddy currents method used for the thickness evaluation of the carburized and induction-hardened layers on the basis of the impedance signal variation. The signal was obtained as a result of the so-called ‘lift off’ effect. A methodology for the quantitative thickness evaluation of the carburized and induction-hardened layers has been elaborated under a range of technological parameters. The measurements ranges were defined in the framework of which an identification of the hardened layer was possible using the commercial defectoscope and reference specimens of the fixed thickness. Tests were carried out on specimens made of the ASM6414 steel and subjected subsequently to carburization and induction hardening. The impedance parameters were measured for selected values of frequency. The results were verified on the basis of metallographic investigations as well as the microhardness measurements captured in the form of profiles taken from specimens’ cross-sections of different layer thickness.
PL
Praca prezentuje możliwości wykorzystania metody prądów wirowych (Eddy Current — ET) do oceny grubości warstw nawęglanych i hartowanych indukcyjnie na podstawie zmian parametru sygnału impedancji. Sygnał ten uzyskiwano w wyniku pojawiania się tzw. efektu oddalenia (lift off). Opracowano metodykę ilościowej oceny grubości warstw hartowanych indukcyjnie otrzymywanych przy różnych parametrach technologicznych. Mając do dyspozycji komercyjny defektoskop diagnostyczny oraz zestawy próbek referencyjnych o ustalonej grubości warstwy, zdefiniowano zakresy pomiarowe, w ramach których jest możliwa ocena grubości warstwy zahartowanej. Badania prowadzono na serii próbek ze stali 40 HNMA poddanych nawęglaniu i hartowaniu indukcyjnemu. Obejmowały one pomiary parametrów impedancji dla wybranych częstotliwości pomiarowych. Wyniki zostały zweryfikowane na podstawie badań metalograficznych oraz pomiarów mikrotwardości w postaci profili wykonanych na przekrojach próbek o różnej grubości warstwy.
EN
Non-invasive damage monitoring of concrete structures by means of Acoustic Emission (AE) requires multitransducers, multi-channel acquisition, high sampling frequency and long observation time. Owing to its propagation in concrete, the signal from AE reduces its amplitude during the propagation, and, consequently, some events can be lost due to lower signal intensity than the trigger level set on one sensor only. The innovative proposal discussed in the paper consists in the introduction of a Flat Amplifier and Trigger generator block (FAT) in order to generate a logical trigger when the AE is detected by any transducer. Experimental tests confirm the effectiveness of the FAT to acquire all the AE events and to increase the evaluation accuracy of damage indexes.
EN
The present study deals with non-destructive application of radioactive tracer isotopes to evaluate the performance of Tulsion A-33 (nuclear grade) and Indion NSSR (non-nuclear grade) anion exchange resins. The performance evaluation was done by carrying out the iodide and bromide ion-isotopic exchange reactions using the above resins. It was observed that at a constant temperature of 40.0 °C, as the concentration of labeled iodide ion solution increases 0.001 M to 0.004 M, the percentage of iodide ions exchanged increases from 58.0 % to 64.0 % for Tulsion A-33 resins; and from 48.4 % to 50.8 % for Indion NSSR resins. Similarly in case of bromide ion-isotopic exchange reaction under identical experimental conditions, the percentage of bromide ions exchanged increases from 45.6 % to 50.4 % for Tulsion A-33 resin; and from 39.8 % to 44.6 % for Indion NSSR resin. It was also observed that during iodide ion-isotopic exchange reaction at 40.0 °C, using 1.000 g of ion exchange resins and 0.003 M labeled ionic solution, using Tulsion A-33 resin the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log Kd were 0.229, 0.469, 0.107 and 10.6 respectively, which was higher than the values of 0.167, 0.375, 0.063 and 7.6 respectively as obtained by using Indion NSSR resins under identical experimental conditions. The overall results indicate superior performance of Tulsion A-33 over Indion NSSR resin under identical operational parameters.
4
Content available remote Obrazowanie ultradźwiękowe wad za pomocą metod syntetycznej apertury
PL
Ultradźwiękowe metody badań nieniszczących przechodzą obecnie metamorfozę od systemów z głowicami jednoelementowymi do systemów wielokanałowych z głowicami fazowymi (PA Phased Array). Prowadzony obecnie w Zakładzie Ultradźwięków IPPT PAN projekt ma na celu opracowanie uniwersalnej wielokanałowej platformy ultradźwiękowej oraz metod rekonstrukcji obrazów mogących znaleźć zastosowanie zarówno w medycynie, jak i w badaniach nieniszczących. Przeprowadzono wstępne badania mające na celu porównanie różnych metod rekonstrukcji obrazów wad w trybie B-mode. W tym celu dokonano akwizycji ech ultradźwiękowych od wad w szynie kolejowej i monobloku przy pomocy ultrasonografu badawczego wyposażonego w 128-elementową głowicą fazową o częstotliwości 4 MHz. Uzyskane sygnały ech wysokiej częstotliwości poddano następnie obróbce cyfrowej w celu uzyskania obrazu B-mode. Zastosowano i porównano różne metody rekonstrukcji obrazu: klasyczny beamforming oraz metodę syntetycznej apertury. Wstępne wyniki wskazują na wysoką jakość rekonstrukcji metodą syntetycznej apertury, która zapewnia równomierną rozdzielczość poprzeczną w całej głębokości obrazowania. Zastosowanie alternatywnych schematów nadawczoodbiorczych w metodzie syntetycznej apertury umożliwia dodatkowo optymalizację metody pod względem prędkości badania lub jakości obrazowania. Wyniki te potwierdzają przydatność i konkurencyjność metody syntetycznej apertury do stosowanej obecnie metody beamformingu.
EN
Nowadays ultrasonic methods of non-destructive testing have undergone transformation from systems with single-element probes into multichannel systems with Phase Arrays probes (PA). The aim of the project currently conducted in Department of Ultrasound in IPPT PAN is to develop a versatile multichannel ultrasonic platform and image reconstruction methods in order to apply both in medicine and in non-destructive testing. Preliminary studies on comparison of different methods of the B-mode image reconstruction for flaw visualization have been done. The acquisition of ultrasonic echoes of defects in railway rail and monoblock, using the research medical ultrasound scanner equipped with 128-element phase array with 4 MHz frequency, has been performed. Then the resulting radio frequency signals of echoes were digitally processed in order to obtain B-mode image. Different methods of image reconstruction – the classic beamforming and the synthetic aperture algorithm – have been applied and compared. The experimental results indicate that the image reconstruction by synthetic aperture method has higher quality then classical beamforming. It provides a uniform lateral resolution throughout the whole imaging depth. The application of alternative transmitting-receiving schemes for the synthetic aperture method additionally allows to optimize it in terms of speed of the testing as well as quality of the imaging. The results confirm usefulness the method and competitiveness of the synthetic aperture to the method of classical beamforming being applied at present.