Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 19

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  non-contact measurement
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Measurement of tool wear using a non-contact method, using a laser measuring system. This article examined the tools - straight cutters with a contactless method using a laser sensor. The first aspect of the research was to determine the influence of the spindle rotational speed on the accuracy of laser measurement. The second aspect of the research was to establish the correlation between the diameter of the tool measured with a laser micrometer and the wear of the tool measured with the microscope. A good (R2> 0.8) Pearson's correlation was found between the measured tool diameter and it’s wear.
PL
Pomiar zużycia narzędzia laserową metodą bezstykową. W ramach pracy zbadano narzędzia – frezy proste metodą bezstykową przy użyciu czujnika laserowego. Pierwszym aspektem badań było ustalenie wpływu prędkości obrotowej wrzeciona na dokładność pomiaru metodą laserową geometrii freza prostego. Drugim aspektem badań było ustalenie korelacji pomiędzy średnicą narzędzia zmierzoną przy użyciu mikrometra laserowego a zużyciem narzędzia określonym przy użyciu mikroskopu. Wykazano dobrą (R2>0,8) korelację pomiędzy zmierzoną średnicą narzędzia a jego zużyciem.
2
Content available remote Analysis of fan blade vibration with a non-contact method
EN
Composite fan blades are more and more common both in aviation and ground applications. This work aims to characterize the vibration parameters of plastic blades installed in a wind tunnel fan by a non-contact method, namely blade tip timing (BTT). Blade dynamics was predicted with finite element modelling (FEM) and confirmed experimentally by tip timing measurements and analysis of data. BTT results were acquired and compared in two different configurations. A good agreement between predicted and measured frequency values was obtained for the fundamental mode. Significant differences were observed for the second and third modes due to material anisotropy and contact effects which could not be modelled because necessary material data were unavailable.
EN
Systems for the automated multi-parametric quality inspection of products manufactured with CNC machines are a key factor in increasing production efficiency. The optomechatronic measuring system developed by the authors of the article enables automatic non-contact quality inspection of products manufactured with CNC machines with efficiency corresponding to the manufacturing process in accordance with the "zero fault" principle. The integrated quality inspection system uses specialised optoelectronic modules to measure dimensions and shape. The developed inspection system was implemented in the machining industry. The solution is dedicated to production systems in accordance with the Industry 4.0 concept.
PL
Systemy automatycznej wieloparametrycznej kontroli jakości wyrobów wytwarzanych na maszynach CNC stanowią kluczowy czynnik w podwyższaniu efektywności produkcji. Opracowany i przedstawiony przez autorów optomechatroniczny system pomiarowy umożliwia automatyczną bezstykową kontrolę jakości wyrobów wytwarzanych na maszynach CNC z wydajnością odpowiadającą procesowi wytwarzania zgodnie z zasadą „zero braków”. W zintegrowanym systemie kontroli jakości zastosowano specjalizowane moduły optoelektroniczne umożliwiające pomiary wymiarów i kształtu. Opracowany system inspekcji został wdrożony w przemyśle maszynowym. Rozwiązanie jest dedykowane do systemów produkcyjnych zgodnie z koncepcją Industry 4.0.
EN
The paper presents the experimental research and numerical simulations of reinforced concrete beams under torsional load. In the experimental tests Digital Image Correlation System (DIC System) Q-450 were used. DIC is a non-contact full-field image analysis method, based on grey value digital images that can determine displacements and strains of an object under load. Numerical simulations of the investigated beams were performed by using the ATENA 3D – Studio program. Creation of numerical models of reinforced concrete elements under torsion was complicated due to difficulties in modelling of real boundary conditions of these elements. The experimental research using DIC can be extremely useful in creating correct numerical models of investigated elements. High accuracy and a wide spectrum of results obtained from experimental tests allow for the modification of the boundary conditions assumed in the numerical model, so that these conditions correspond to the real fixing of the element during the tests.
PL
Celem niniejszej pracy jest walidacja warunków zamocowania modeli numerycznych wspornikowych belek żelbetowych jednocześnie zginanych, ścinanych i skręcanych, na podstawie danych uzyskanych z badań doświadczalnych, przeprowadzonych za pomocą systemu cyfrowej korelacji obrazu. W badaniach doświadczalnych wykorzystano system cyfrowej korelacji obrazu Q-450 firmy Dantec Dynamics. Cyfrowa korelacja obrazu, często określana skrótem DIC (z ang. Digital Image Correlation), jest bezkontaktową metodą pomiarową. Pozwala ona na określenie przemieszczeń i odkształceń badanych obiektów, zarówno w przestrzeni dwuwymiarowej, jak i trójwymiarowej, na podstawie zdjęć wysokiej rozdzielczości, które zostały zarejestrowane podczas zmiany położenia lub kształtu badanego obiektu. Metoda ta opiera się na zaawansowanych systemach optyczno-elektronicznych, w skład których wchodzą kamery wysokiej rozdzielczości, jak również szybkie kamery pozwalające na rejestrację obrazów podczas zdarzeń szybkozmiennych [5-7, 11, 15, 18]. Wykorzystanie systemu DIC w badaniach doświadczalnych żelbetowych belek skręcanych pozwoliło na uzyskanie szeregu danych, które mogą służyć do walidacji modeli numerycznych badanych obiektów. System do pomiarów wizyjnych Q-450 umożliwił jednoczesny pomiar przemieszczeń ok. 2500 punktów znajdujących się na bocznej powierzchni belki. Zastosowanie w badaniach żelbetowych belek wspornikowych systemu DIC pozwoliło między innymi na określenie linii ugięcia belki oraz wartości odkształceń w każdej sekundzie badania, jak również obserwację rozwoju rys na badanej powierzchni belki w czasie badania, określenie przebiegu rys oraz pomiar kąta ich nachylenia w czasie, gdy rysy nie były jeszcze widoczne gołym okiem.
PL
W artykule pokazano możliwość zastosowania metody wizyjnej, jaką jest metoda cyfrowej korelacji obrazów (ang. Digital Image Correlation, DIC), do identyfikacji uszkodzeń w konstrukcjach budowlanych na przykładzie stalowej ramy dwukondygnacyjnej. W tym celu przeprowadzono pomiary przemieszczeń metodą DIC na wybranym fragmencie ramy obciążonej dynamicznie, dla różnych wariantów uszkodzenia wprowadzanego w połączeniach dolnego rygla ze słupami. Przeanalizowano otrzymane wartości przemieszczeń. Wyniki przeprowadzonego eksperymentu wskazują na duży potencjał w zastosowaniu metody DIC, jako alternatywnej metody pomiarowej, pozwalającej pozyskać dane wykorzystywane np. do detekcji uszkodzeń konstrukcji. W pracy pokazano również możliwość zastosowanie prezentowanego systemu do pomiarów szybkozmiennych.
EN
The paper presents the possibilities of applying the visual measurements (namely Digital Image Correlation method, DIC) in the damage identification of building structures on the example of a two-storey steel frame. For this purpose, displacement measurements were carried out on a selected fragment of the steel frame subjected to a dynamic load, for the various variants of the damage introduced in the column – lower spandrel beam joints of the frame. The obtained displacement values were analyzed. The results of this experiment indicate a high potential of the DIC application as an alternative measurement method, which allows to obtain data used for instance in the damage detection. The paper also shows the possibilities of applying the presented system for fast-change measurements.
PL
W ostatnich latach jako alternatywę dla tradycyjnych metod pomiarowych przemieszczeń i odkształceń zaczęto intensywnie rozwijać metody bezkontaktowego pomiaru opierające się na systemach optyczno-elektronicznych. Jednym z takich bezkontaktowych systemów pomiarowych jest system cyfrowej korelacji obrazu (ang. Digital Image Correlation, DIC), umożliwiający rejestrację i analizę pól przemieszczeń i odkształceń na powierzchni badanego obiektu w przestrzeni trójwymiarowej. W artykule przedstawiono system 3D DIC na przykładzie systemu Q-450 firmy Dantec Dynamics oraz jego zastosowanie w badaniach połączeń elementów konstrukcji stalowych; omówiono zasadę jego działania i etapy badań. Ponadto w pracy opisano zalety i ograniczenia systemu oraz zakres jego zastosowań. Narzędzia analizy pól przemieszczeń i odkształceń dostępne w programie Istra 4D, stanowiącym część systemu Q-450, pozwalają na szczegółowe określenie deformacji próbki i zjawisk zachodzących w czasie jej obciążania oraz stwarzają możliwość różnorodnej wizualizacji wyników badań. Informacje zawarte w artykule mogą być przydatne dla przyszłych użytkowników systemu i przyczynić się do szerszego stosowania metod bezkontaktowych w pomiarach przemieszczeń i odkształceń.
EN
In recent years, as an alternative to traditional methods of displacements and strains measurements, non-contact methods based on opto-electronic systems have been developed. One of them is the digital image correlation (DIC) system which allows for the registration and analysis of the displacements and strains fields on the surface of the investigated object in three-dimensional space. The paper presents 3D DIC on the example of the Q-450 system from Dantec Dynamics and its application in the study of steel structure elements connections, discusses the principle of its operation and test stages. In addition, the paper describes the applicability of the system, its advantages and limitations. A wide analysis of displacements and strains fields with the use of various tools available in the Q-450 software Istra 4D allows detailed description of the investigated object deformation and the phenomena occurring when the object is loaded. Information presented herein may be useful for future system users and contribute to wider usage of non-contact methods in displacements and strains measurements.
PL
Przedstawione w artykule badania eksperymentalne mają na celu ustalenie, jaki wpływ na wynik pomiaru odchyłki okrągłości uzyskanych pneumatyczną metodą pomiarową ma zmiana prędkości obrotowej stolika pomiarowego. W pomiarach wykorzystano przetworniki wyposażone w klasyczne dysze pomiarowe o przekroju kołowym; pomiary wykonano za pomocą przetwornika wyposażonego w dyszę szczelinową.
EN
The article presents in experimental studies is to determine the impact on the result obtained roundness deviation pneumatic measuring method is to change the speed of the measuring table. In the measurements used gauge with classical measuring nozzles of circular hole and measurements were used by the air gauge with a slotted nozzle.
PL
W artykule przedstawiono problematykę pneumatycznych pomiarów wielkości geometrycznych. Opisano budowę i zasadę działania pneumatycznych przetworników długości. Zaprezentowano przykłady zastosowania wymienionych przetworników w pomiarach wielkości geometrycznych. W przeciwieństwie do metody stykowej, pomiar metodą bezstykową umożliwia kontrolę o charakterze czynnym oraz pomiar elementów wykonanych z materiałów, w których nacisk końcówki pomiarowej może niekorzystnie wpłynąć na wynik pomiaru.
EN
The paper presents problems of pneumatic measurement of geometrical quantities. The initial section presents a short history of the compressed air application to measurements of machine parts. The attention is paid to the theoretical basis of this topic [1, 2]. The construction and operation of an air gauge are described. The paper presents a physical model of the air gauge (Fig. 1) and the advantages of its use in particular measurement tasks. The Department of Metrology and Measurement Systems, Poznan University of Technology, conducted a number of research and practical application of air gauges, which resulted in a number of patented measuring devices for measuring form deviations. Section 3 presents examples of these gauges in the designed and constructed devices for measurement of geometrical quantities (Figs. 3, 4, 5, 6). The paper ends with a short summary. The non-contact method of measurement, in contrast to the contact one, allows for in-process control (check of the dimensions directly during the process) and measurement of material components, in which the stylus pressure can adversely influence the measurement result. It should be noted that in some cases the pneumatic measurement method cannot be replaced by any other method. The advantages of air gauges proved the usefulness of the theoretical analysis and experimental investigations.
PL
W artykule opisano pomiary odchyłki okrągłości za pomocą pneumatycznych przetworników długości wyposażonych w szczelinowe dysze pomiarowe. W wyniku przeprowadzonych badań wyznaczono charakterystyki statyczne pneumatycznych przetworników długości z szczelinowymi dyszami pomiarowymi. Zaprezentowano wyniki pomiaru odchyłki okrągłości dla wybranych typów dysz oraz dokonano oceny dokładności pomiaru uwzględniając wartość odchyłki okrągłości jak i zmiany amplitud składowych zarysu. Rezultaty przeprowadzonych badań porównano z metodą stykową. Pomiary zarysu okrągłości potwierdziły przydatność zastosowania dysz szczelinowych w bezstykowych pomiarach okrągłości.
EN
In the paper, issues of measurement of roundness deviation using the air gauge with slotted meas-urement nozzles have been described. As a result of experimental investigations, determination of air gauges static characteristics with slotted measurement nozzles was conducted. Results of measurement of roundness for air gauge with selected types of nozzles was presented. Then it was observed the dependencies between parameters of the model shape, and errors of measurement obtained using air gauge. The results of experimental investigations was compared with those from the contact method. The results of experimental investigations indicate that, there is the possibility to use air gauges with slotted nozzles in measurement of roundness.
PL
W pracy przedstawiono układ regulacji liniowego serwonapędu elektropneumatycznego, w którym do pomiaru przemieszczenia użyto czujnika laserowego. Zastosowanie takiego czujnika umożliwia wykonanie pomiaru odległości metodą bezkontaktową. W opracowany systemie pomiarowym zastosowano adaptacyjny układ regulacji serwonapędu elektropneumatycznego. Przedstawiono wyniki badań porównawczych dotyczących jakości pozycjonowania przy zastosowaniu laserowej i magnetostrykcyjnej metody pomiaru przemieszczenia serwonapędu.
EN
The paper presents a control system for an electro-pneumatic servo-drive which was used to measure the displacement of a laser distance sensor. The use of this sensor allowed applying the non-contact measurement method. The aim of this study was to develop a measurement system for control of an electro-pneumatic servo-drive. The control system contains an adaptive controller. The paper also presents the results of the positioning quality when using a laser and a magnetostrictive sensor. Laser non-contact sensors are used to accurately measure the length and speed of movement of a device and to optimize the manufacturing process. In laser measuring techniques, there is no need for a continuous contact with the element measured. The basic element of the system is a pneumatic cylinder. This actuator is equipped with a magnetostrictive displacement sensor. Fixing of the magnetostrictive displacement sensor needs changes into the actuator construction. In the case of a pneumatic cylinder, installation of the measuring system is difficult and in many cases impossible. The mounting of the sensor can be a source of the measurement inaccuracy. The laser measurement system can be an alternative to the magneto-strictive method of measuring.
PL
W artykule omówiono wybrane aspekty analizy niepewności pomiaru długości z użyciem przetwornika pneumatycznego. W celu wyznaczenia niepewności pomiaru szerokości szczeliny s, przy wykorzystaniu systemu pomiarowego wyposażonego w pneumatyczny przetwornik długości oraz przetwornik ciśnienia, zastosowano procedurę wzorcowania i estymacji współczynników charakterystyki statycznej. Badania przeprowadzono dla przetworników z różnymi zestawami dysz. Przyjęte zestawy umożliwiły uzyskanie parametrów metrologicznych stosowanych w przemysłowych przyrządach pomiarowych. Uzyskane wyniki poddano analizie statystycznej i w jej efekcie ustalono, w jakim zakresie znajduje się poprawna wartość mierzonej szerokości szczeliny pomiarowej s.
EN
This paper discusses some aspects of measurement uncertainty analysis in air gauges for measurement of length. Investigations was conducted on selected transducers with different sets of nozzles. Adopted combinations of nozzles enabled estimation of metrological parameters used in measuring instruments in conditions corresponding to those applied in industrial applications. The slot size was determined by the measurement system equipped with the air gauge equipped with pressure transducer. In order to evaluate the measurement uncertainty calibration procedure using the estimation of coefficients for static characteristics were applied. The results were statistically analyzed and the range in which there is a correct value of the measured slotsize s was determined.
PL
W artykule przedstawiono wyniki pomiarów odchyłki okrągłości uzyskanych bezstykową metodą pneumatyczną. Rezultaty przeprowadzonych badań porównano z metodą stykową, gdzie odchyłki okrągłości wyznaczano za pomocą urządzenia PIK-2. Charakterystyki statyczne wyznaczone dla różnych zestawów dysz wlotowych i pomiarowych wykazały, że wraz ze wzrostem średnicy dyszy wlotowej dw wzrasta zakres pomiarowy, natomiast czułość ulega zmniejszeniu. Istotne znaczenie przy doborze zestawu dysz do danego zadania pomiarowego ma odpowiednie skonfigurowanie średnic: dyszy wlotowej i dyszy pomiarowej. W przypadku zestawu dysz dp = 1,012 mm, dw = 0,710 mm odchyłka okrągłości była najbardziej zbliżona do wartości uzyskanej dla metody stykowej.
EN
This paper presents results of roundness measurements obtained using non-contact pneumatic method. The results of experimental investigations was compared with those from contact method, where the roundness was determined using the form tester PIK-2. The static characteristics was determined for different sets of inlet nozzles and measurement nozzles. On the basic of those research, the increase in diameter of inlet nozzle dw with the increase of measuring range was determined. Nevertheless the sensitivity of the gauge was decreased. Proper choice of nozzles set, especially, configuration of inlet and measuring nozzles diameter, for particular measuring task has significant meaning. In the case of a set of nozzles dp = 1.012 mm, dw = 0.710 mm roundness was the most similar to the roundness obtained for the contact method.
PL
W artykule przedstawiono sposób użycia elektromechanicznej folii EMFi do pomiaru częstości skurczów serca człowieka. Stanowisko pomiarowe składa się z dwóch sensorów EMFi, umieszczonych na typowym krześle biurowym, modułu referencyjnego do pomiaru EKG i SpO2 oraz karty DAQ. Wyznaczono wartość tętna dla sygnału EMFi i EKG. Błąd pomiaru tego parametru określony z serii pomiarów wykonanych w czasie 1 minuty i szacowany jako różnica między sygnałem pochodzącym z EMFi a sygnałem EKG wynosi < 1 %.
EN
The Electro-Mechanical Film (EMFi) sensor for measurement of the human heart rate is presented. EMFi material is used to non-invasive technique for the assessment of the cardiac function called ballistocardiography (BCG). Construction and sensor operation are shown in Fig. 2. There was built a measurement setup from a typical office chair with ECG and SpO2 reference module (Fig. 4) for obtaining the ballistocardiogram . The EMFi signals from a subject sitting on the chair are recorded by a specially-designed amplifiers, analog filters and dedicated data acquisition card. A Matlab PC software was used for recording, data processing and displaying the results. EMFi sensors were mounted on the chair seat and backrest. The example signals are shown in Figs. 5, 6. The authors' method was evaluated by comparing the beat-to-beat heart rate (HRBB) values obtained from the EMFi sensors with the accurate reference values calculated from the reference ECG signal. The experimental results (calculated heart rate) are presented in Figs. 9, 10. The measurement error for the HRBB parameter, estimated as a difference between the EMFi and reference signal, is below 1 %, during 60-second recording.
PL
Artykuł przedstawia układ do monitorowania aktywności elektrycznej serca z użyciem bezkontaktowej metody pojemnościowej. Czujnikami potencjałów na powierzchni skóry są sensory pojemnościowe, specjalnie do tego celu zaprojektowane. Pomiar wykonywany jest poprzez ubranie badanej osoby w pozycji siedzącej. Sensory umieszczone są na oparciu krzesła. Dla zmniejszenia wpływu zakłóceń zastosowano aktywną elektrodę odniesienia również ze sprzężeniem pojemnościowym, na której badana osoba siedzi.
EN
The paper presents a system for heart activity monitoring without a direct conductive skin contact. The system utilizes capacitively coupled sensors specially designed for measurements of electric potentials on a human body. In addition, to reduce common mode effects, there is employed a capacitive "driven seat ground" active electrode, similar to the "driven right leg" feedback. Section 1 contains a short description of the non-contact measurement techniques which do not require use of conductive gels and direct electric contact with skin, which may result in skin irritation. Section 2 deals with the measurement system. Amplifiers and filters are briefly discussed. A capacitive sensor is presented in detail. Examples of measurements through clothes are given in Section 3. The results for various areas of the reference electrode and during body movement are also included.
PL
W artykule przedstawiono zastosowanie metody prądów wirowych do pomiarów konduktywności, grubości ścianek obiektów, grubości powłok zabezpieczających oraz wczesnego wykrywania defektów materiałowych. Przedstawiono wykonane stanowisko pomiarowe laboratoryjne do prowadzenia badań w tym zakresie oraz wzorce konduktywności i wzorce wad typu nieciągłości.
EN
The paper deals with eddy current methods applied to measurements of material conductivity, wall thickness, thickness of protective coatings and early detection of material discontinuities. The testing measurement stand using a neural network approach to a flaw parameters evaluation, based on designed by author sets of conductivity standards and material flaw standards have been presented.
PL
W artykule omówione zostały technologie bezdotykowej kontroli jakości wykonania produktu. Omówiono metodę wizji aktywnej wraz z prezentacją metody pozyskiwania obrazu oraz metody tworzenia modelu trójwymiarowego badanego przedmiotu. Przedstawiono porównanie kontroli produktu z zastosowaniem wizji aktywnej oraz metod stosowanych w praktyce produkcyjnej. Przedstawiono przykłady realizacji pomiarów na modelu trójwymiarowym oraz zaprezentowano analizę koncepcji wykorzystania metody wizji aktywnej do pomiaru przedmiotu obrabianego na frezarkach CNC.
17
Content available remote Nowa metoda pomiaru współczynnika koncentracji naprężeń
PL
Przedstawiono nową metodę wyznaczania współczynnika koncentracji naprężeń w złączach spawanych opartą na wideoekstensometrze jako elemencie pomiarowym. Podano wyniki badań mających na celu określenie warunków początkowych do pomiaru odkształceń przy użyciu wideoekstensometru oraz podstawowe problemy związane z wykorzystaniem kamery wideo. Przedstawiono także wstępne wyniki pomiaru odkształceń z wykorzystaniem badanego urządzenia.
EN
It has been presented a new method of determination of stress concentration factor in welded joints, based on the video extensometer as the measuring element. The results of investigations aimed at the determination of initial conditions for measurement of distortions with the use of video extensometer have been given and the main issues connected with the use of video camera have been discussed. The preliminary results of measurements of distortions with making use of the tested device have been also presented.
EN
This paper presents the developed 3D profilometers for surface inspection and profile measurement based on the triangulation principle. The applied compact high-resolution laser triangulation sensors with the mechatronics positioning system and computer data analysis enable the surface profile reconstruction for applications in industry as well as in research. The application tests were done on various specimens. Suitable filters can be applied to eliminate signal noise and disturbances and to improve the computer image visualisation.
PL
Artykuł przedstawia opracowane profilometry 3D do inspekcji powierzchni i pomiarów jej profilu w oparciu o zasadę triangulacji. Zastosowane triangulacyjne głowice laserowe wysokiej rozdzielczości z mechatronicznym systemem pozycjonowania i komputerową analizą danych umożliwiają odtwarzanie zarysu powierzchni do zastosowań w przemyśle i badaniach naukowych. Testy zostały wykonane na różnych próbkach. W celu eliminacji szumów oraz zakłóceń i uzyskania wizualizacji komputerowej zastosowano odpowiednie filtry.
PL
W artykule przedstawiono wyniki badań, których bezpośrednim celem było zaproponowanie koncepcji realizacji bezstykowych pomiarów średnicy kół zestawu wagonowego. Badania skoncentrowano na analizie wybranych zagadnień związanych z przetwarzaniem obrazów modeli koła z zastosowaniem metod krawędziowania. W efekcie przeprowadzonych badań potwierdzono możliwość realizacji pomiarów średnicy modelu kół zestawu wagonowego z zastosowaniem systemów wizyjnych.
EN
The paper presents a certain approach to diameter measurements of railway axle set wheel. The main goal of the presented research was to verify possibility of applying vision system for such measurements. The tests have been conducted with a model of axle set wheel. Several problems related to vision system application have been discussed. Among others, different image calibration techniques were analysed. Also, a possibility of single image calibration for measurements of wheels with different diameter was considered. It has been revealed that the wheels can be measured with satisfying accuracy based on few images of a wheel rotating in front of the camera. However, distinct problems have been pointed at while analysing practical implementation of the proposed approach in the industrial conditions. These problems reflect our future work.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.