Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  nośność pala
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Results of the “DPDT-Auger” research project on screw displacement piles
EN
The main objective of the “DPDT-Auger” research project was to test the prototype DPDT auger for forming screw displacement piles in the ground (patented in Poland in 2020). An additional aim was to develop design methods and rules for the making of such piles. The augers and piles were first tested on a model scale, and then more extensively in the real scale on experimental field plots. The results found the overall functionality of the DPDT auger to be good, and in several aspects better than that of the SDP auger. The load-bearing capacities and Q-s characteristics of piles made with both augers were considered comparable. All the conducted tests and their derived dependencies together with the results of in situ subsoil tests allowed for the development of empirical calculation methods and prognostic procedures, useful for designing and producing piles with DPDT and SDP augers. FEM numerical simulation rules for the considered piles were also developed, verified and calibrated by the results of real pile tests. This article describes only the most important final results of the research project but not the detailed results of the numerous tests and analyses that were carried out. Also omitted are the results of model tests and numerical simulations, as well as the implementation and acceptance recommendations, as they have already been or will be the subject of separate publications.
PL
W pracy przedstawiono analizę dotyczącą wpływu zmiany długości oraz średnicy pala na przebieg zależności Qs. Do opisu próbnych statycznych obciążeń wykorzystano metodę Meyera-Kowalowa. Analiza wyników testów statycznych przeprowadzonych w pełnym zakresie obciążenia umożliwiła opisanie związku między nośnością graniczną pala a jego geometrią. Proponowane rozwiązanie pozwala na określenie zmiany przebiegu zarówno krzywej oporu całkowitego pala, jak również oporu podstawy oraz pobocznicy.
EN
The paper presents an analysis of the impact of changed diameter and length of a pile on the Q-s relation. The Meyer-Kowalow method has been used to describe the static test load. The analysis of the results of static tests carried out in the full load range made it possible to describe the relation between the pile bearing capacity and its geometry. The proposed solution enables determining the change of the pile total resistance curve as well as the base and side surface resistance.
PL
W obowiązującej w Polsce normie dotyczącej projektowania geotechnicznego posadowień na palach – Eurokod 7 (PN-EN 1997-1, 2008) – podano 4 metody obliczania fundamentów palowych (pkt 7.4.1 normy). Jedną z nich jest projektowanie na podstawie obliczeń z wykorzystaniem metod empirycznych lub analitycznych, do takich zalicza się projektowanie na podstawie wyników badań sondą statyczną CPTU.
EN
The article presents the information on the authors experience related to the design and completion of pilling works designed based on the results of the CPTU soundings, gained during many years of completing large-scale motorway projects. The first parts gives the examples of pile bearing capacity calculations based on methods that apply the results of the CPTU testing. The second part of the article presents a critical analysis of the CPTU results presentation and interpretation, which is crucial for further design analysis.
PL
Praca jest kontynuacją badań Autorów nad modelem krzywej Meyera Kowalowa[8] opisującej zachowanie pala pod obciążeniem. W artykule podano propozycję opisu parametrów modelu krzywej MK w nawiązaniu do wyników sondowania CPT. W części obliczeniowej przedstawiono analizę zachowania pali przemieszczeniowych SDP pod próbnym obciążeniem statycznym, posiłkując się badaniami literaturowymi i własnymi. Autorzy proponują metodę określania nośności pobocznicy pala, którego podstawa jest zagłębiona w zagęszczone grunty niespoiste na podstawie wyników badań sondowania statycznego CPT, jednocześnie porównując wyniki otrzymane w analizie do wyników badań literaturowych i własnych. Zróżnicowane metody określania nośności podstawy pala na podstawie sondowania CPT prowadzą do otrzymania szeregu krzywych obrazujących nośność pobocznicy. Cechą wspólną tych krzywych jest występowanie maksimum dla oporu pobocznicy.
EN
Paper presents the proposal of modelling the shaft of pile resistance, by using of Meyer Kowalow method. Meyer Kowalow method is known as a method of static pile load test interpretation. It was well presented in literature by Meyer and Kowalow[8], Meyer and Szmechel (2011), Meyer (2013), Szmechel[18]. Meyer Kowalow method is mainly used to predict ultimate bearing of the pile. During the analysis of pile load settlement curve we get also additional coefficients like C, and ĸ. It’s probable that those additional coefficients are directly bounded with soil properties. According to this, parts of MK coefficients are taken directly from cone penetration test results as a proposal. Authors want to use of MK method to predict changes of shaft of the pile resistance, in case when the pile base is recessed in very dense noncohesive ground. For this case it is possible to assume that pile works separately in two different cases. In case one only base of the pile takes part of the pile resistance and when the case two is realized both shaft and base works together. Paper presents six different cases of pile behavior under static pile load test, their settlement and shaft base-relation resistance analysis for practical cases of pile foundation.
5
Content available remote Badania dynamiczne pali na wiadukcie kolejowym linii CMK
PL
Projektanci fundamentów palowych chętnie korzystają z możliwości badań dynamicznych, szczególnie tam,, gdzie badanie statyczne jest trudne do zrealizowania.
6
Content available remote Weryfikacja nośności pala ustalonej na podstawie badań CPTU
PL
W pracy zaprezentowano metody oceny nośności pali bazując na rozpoznaniu podłoża gruntowego sondą statyczną CPTU. Przedstawiono możliwe do zastosowania w warunkach rzeczywistych metody służące bezpośredniej ocenie nośności pali wykonywanych w technologii CFA. Obliczenia przeprowadzono dla pojedynczego pala i odniesiono do metody uniwersalnej proponowanej w Eurokodzie 7 oraz metody normowej zgodnej z normą PN-83/B-02482. Otrzymane wyniki poddano weryfikacji poprzez porównanie z wartością graniczną nośności pala wciskanego uzyskaną z próbnego obciążenia statycznego. W pracy przedstawiono propozycję doboru lokalnych współczynników nośności podstawy ψ1 oraz pobocznicy ψ2. Wartości współczynników ustalono na bazie wyniku próbnego obciążenia statycznego pala oraz szacunkowej nośności pobocznicy i podstawy pala z globalnej charakterystycznej wartości nośności pala w warunkach rzeczywistych.
EN
The paper presents methods for assessing pile capacity based on the recognition of susbsoil by the use of a static CPTU probe. Feasible methods, under real conditions, for direct assessment of the pile bearing capacity made with CFA technology are presented. Calculations were performed for a single pile and referred to the method being in accordance with Eurocode 7 and standardized methods compatible with the PN-83/B-02482. The results were verified by comparing the value of the pile limit load achieved with the pile static load test. The paper presents a proposal for a selection of the ψ1 and ψ2 factors. The values of these factors were determined on the basis of a trial pile static load test as well as the estimated capacity of the shaft and the base of the pile in the global characteristic values of pile capacity under real conditions.
PL
W pracy przedstawiono analizę prezentowanej w 2012 roku metody interpretacji wyników testów statycznych pali [8,9] wykorzystując równanie zaproponowane przez Meyera i Kowalowa [7]. Wykonano eksperymenty numeryczne na palu teoretycznym, porównano wyniki badań z wartościami oczekiwanymi, i dokonano wyboru funkcji opisującej jeden ze współczynników równania podstawowego, jako lepiej opisującej proponowaną metodę.
EN
The main aim of the work is to define better correlation between parameters of Meyer- Kowalów equation [7,8] with the use of mathematical experiments and statistical tests. So far the research has shown that correlation between particular factors are different than common assumed. It was necessary to check non linear correlations between C-constant and K. A certain constant and starting data were assumed in the theoretical model applied to the paper. As a result of the mathematical experiments, the best fit proposal of estimation C and equation representing=(Ngr)was formulated.
EN
The paper presents estimation of the pile bearing capacity based on actual findings of the CPTU static probe. The calculations were performed by the methods of Adamczyk, Gwizdała, Energopol, Wiłun, Gianeselle i Bustamante and Philipponant, Kłos. Design methods were divided into four groups in terms of their suitability for specific pile manufacture technologies. For the estimation of bearing capacity a pile dimension was assumed, and for the particular capacity a length was sought, at which the capacity would be ensured. All results were compared to the method derived from Eurocode 7.
PL
W pracy przedstawiono oszacowania nośności pala wciskanego na podstawie wyników badań sondą statyczną CPTU. Obliczenia analityczne wykonano dla rzeczywistych warunków gruntowych w miejscu planowanego posadowienia obiektu inżynierskiego. W pracy przedstawiono zarejestrowane podczas sondowania statycznego pomiary oporu wciskania na stożku q/c, oporu tarcia na tulei ciernej f/s i ciśnienia porowego u/2 oraz wyznaczony profil geologiczny wg klasyfikacji normowej PN-B-04452:2002. Oszacowanie nośności wykonano ośmioma metodami: Adamczyka, Gwizdały, Energopolu, Wiłuna, Gianesellego i Bustamantego oraz Philipponanta, Kłosa, a także normowymi PN-83/B-02482 i PN-EN 1997-2:2009 (Eurokod 7).
9
Content available remote Calculation of piles based on CPT results in POLAND
EN
The paper presents the capacity of driven precast pile prediction method based on the results of CPT tests. The pile settlement equal to 10% of pile diameter is assumed as a criterion of pile capacity. The method gives also a unit skin friction and a unit base resistance for intermediate pile settlements. This allows us to simulate the load-settlement curve and to calculate the axial stiffness of the pile in any load range. For the purpose of analysis the calculation file is created which makes it possible to compare the results of calculation with those of the field-test. The comparative analysis of 37 square 0.3 m × 0.3 m and 0.4 m × 0.4 m piles in clays and sands was carried out. The comparison shows a good agreement between the predicted and actual capacities and a satisfactory agreement between the predicted and actual slopes of the load-settlement curve in the range up to 40% of the ultimate pile capacity.
10
Content available remote Kontrola nośności pali i jakości robót palowych
PL
Znaczący postęp w technologii fundamentowania głębokiego, w tym fundamentów na palach, oraz wprowadzenie dużych, silnych maszyn stworzyło zupełnie nowe możliwości rozwiązań , a w związku a tym powstały nowe przepisy, normy, zalecenia. Przedstawiono aktualne metody badań w celu oceny nośności pali oraz metody kontroli ich jakości.
EN
The paper addresses the currently applied testing methods of assessing the load bearing capacity of piles and their quality control. The issues presented describe test static and dynamic loads as well as other quality tests of piles. A number of examples has been presented to illustrate the use of an integrated test program for structures founded on piles.
PL
Omówiono metodę obliczania nośności i osiadania pali z uwzględnieniem bezpośredniego wykorzystania wyników badań sondą statyczną CPT. Dla oceny krzywej osiadania zastosowano funkcje transformacyjne. Przedstawiono analizę wykorzystując wyniki próbnych obciążeń statycznych pali. Zaproponowane korelacje zostały zweryfikowane przy wykorzystaniu procedury weryfikacji hipotez statystycznych.
EN
The method of calculation of bearing capacity and settlements of piles on the basis of direct use of CPT test results is presented. For the determination of load-settlement curve, up to ultimate load, the load-transfer functions' method is used. The filed investigations covered loading tests and CPT testing made in the area of piling. The correlations obtained were next verified using verification procedure for statistical hypotheses.
PL
W pracy zestawiono wyniki serii badań modelowych wciskania pali przeprowadzonych w zagęszczonym piasku Lubiatowo przy różnym poziomie naprężenia w komorze oraz przy różnych warunkach brzegowych. Przeanalizowano wpływ warunków brzegowych na wartości tarcia średniego oraz jednostkowego oporu podstawy pali modelowych. Zaobserwowano istotny wpływ warunków brzegowych podczas wciskania pali na składową poziomą naprężenia wokół masywu gruntowego oraz na tarcie na pobocznicy.
EN
A series of model tests on instrumented piles pushed into the soil was performed in the calibration chamber in dense Lubiatowo sand for various stress level and boundary conditions. The influence of boundary conditions on point resistance and lateral friction was analysed. A considerable influence of boundary conditions was observed for lateral friction.
PL
Przedstawiono charakterystykę badań dynamicznych pali (DLT) w odniesieniu do wielkośrednicowych pali wierconych. Na przykładzie badań przeprowadzonych na kilku obiektach mostowych w Polsce omówiono zależność między wynikami próbnych obciążeń statycznych (SLT) oraz wynikami badań dynamicznych.
EN
Characteristic of Dynamic Load Testing with reference to large diameter bored piles is presented. Relation between results of static load (SLT) and dynamic tests (DLT) are discussed based on a few examples of tested piles in several bridge structures.
PL
W referacie przedstawiono poligon badawczy nośności pali formowanych w ekspansywnych iłach trzeciorzędowych. Na zaprojektowanym w Katedrze Geotechniki poligonie możliwe jest oddzielne oznaczenie nośności pobocznicy, podstawy i całkowitej nośności pala. Analizowane są między innymi nośności pali w różnym stanie wilgotnościowym iłów podłoża: podłoże naturalne - iły "suche" oraz podłoże wstępnie zalane wodą, "iły spęczniałe". Wykonano próbne obciążenia dla każdego przypadku badanych pali. W przypadku spęczniałych ekspansywnych iłów, rzeczywista nośność całkowita i nośność pobocznicy jest niższa o co najmniej 40% od nośności pali obliczonej wg Polskiej Normy.
EN
The paper presents a test site for the bearing capacity of in-situ cast piles in expansive Tertiary clays. The investigations have enabled to determine separately the bearing capacity of piles shaft and base. The piles bearing capacity due to the influence of water content in the clays was determined too.
PL
Referat przedstawia wstępne analizy projektu badawczego, którego celem jest zebranie i ocena wyników badań nośności pali CFA wykonywanych w Polsce. Zebrano dotychczas wyniki blisko 80 badań od kilku wykonawców pali. Pale o średnicach od 400 mm do 1000 mm były posadowione w różnych gruntach, na wielu obiektach. Analizowane wyniki są reprezentatywne dla obecnej praktyki palowania. Ocena wyników pozwoliła uzyskać parametry charakteryzujące stosowane wymiary oraz nośności i osiadania pali. Uzyskane dane pozwolą przewidywać sztywność osiową pali w zakresie obciążeń użytkowych.
EN
The paper presents results of a research project aimed on collecting and evaluating results of loading tests of CFA piles constructed in Poland. For the analysis about 80 test results have been collected from several pile contractors. The tested piles of 400 mm to 1000 mm in diameter were embedded in various soils on many sites throughout Poland. The analysed results are representative for the actual piling practice. The evaluation of results enabled to derive typical data describing dimensions, bearing capacity and settlement of piles. The data obtained are useful for prediction of a pile axial stiffness in the range of working loads.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.