Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  natural frequencies of the structure
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper, the analysis of the influence of the changes in shaping steel hall pillars of its dynamic characteristics, in particular of the value of the natural frequency, has been subjected. The moment of inertia about the axis of the transverse profile of a typical arrangement of the pile and its mass influence on the dynamic characteristics of the steel pillars hall. These factors are different for different types of steel poles profile. The article presents the results of the analysis of the influence of the shape of the three selected types of profiles on the dynamic characteristics of the steel hall. Steel hall selected for the analysis is a workshop, a single nave hall with a frame structure covered with a gable roof. Profile sections of load bearing pillars used for the analysis are: IPE 450, 280 HEB, HEM 220. These profiles were selected due to similarities between stress levels. The evaluation shall assess the influence of such dimensional manipulation on change of the construction costs of the steel hall selected for analysis. Static design and modal analysis was made in Robot Structural Analysis which is FEM engineering program.
PL
W artykule analizie poddano wpływ zmiany kształtowania słupów hali stalowej na jej charakterystyki dynamiczne, a w szczególności na wartości częstotliwości drgań własnych. Na charakterystyki dynamiczne słupów hali stalowej mają wpływ moment bezwładności względem osi poprzecznej profilu przy typowym układzie słupa oraz jego masa. Czynniki te są różne dla różnych typów profili słupów stalowych. W artykule przedstawiono wyniki analizy wpływu kształtu trzech wybranych typów profili na charakterystyki dynamiczne hali stalowej. Wybrana do analizy hala stalowa to hala warsztatowa, jednonawowa o ramowej konstrukcji przykryta dwuspadowym dachem. Profile kształtowników słupów nośnych użyte do analizy to: IPE 450, HEB 280, HEM 220. Profile te zostały wybrane ze względu na podobny stopień wytężenia. Ocenie podlegał także wpływ takiej manipulacji wymiarowej na zmianę kosztów budowy wybranej do analizy hali stalowej. Wymiarowanie statyczne oraz analizę modalną konstrukcji hali stalowej wykonano w inżynierskim programie Robot Structural Analysis.
EN
A dynamic response of structures determine its dynamic characteristics, i.e. the natural frequency, the corresponding figures of vibration and damping coefficient. Designing of a building in terms of dynamics lets us interfere in its stiffness and mass which allows the derivation of the structure of the resonance zone early in the design stage. It is known that the larger the value of the natural frequency the greater the stiffness of the whole structure. The article examined how the natural frequencies of the objectchange under the influence of adjustments in the development of the floor model. The main purpose of the analysis carried out in the article was to determine the relationship between stiffness and mass matrices and the results of the modal analysis of the chosen structure. The article hypothesized that the natural frequency is inversely proportional to the mass of the floor raised to a suitable exponent. A formula derived from this relationship has been verified on a number of variants of the building model made in the program for numerical calculation Dlubal.
PL
Odpowiedź dynamiczną budowli determinują jej charakterystyki dynamiczne tj.: częstotliwości drgań własnych, odpowiadające im postacie drgań i współczynnik określający tłumienie drgań. Projektując budowlę pod względem dynamicznym można ingerować w jej sztywność i masę co pozwala na wyprowadzenie konstrukcji ze strefy rezonansowej już na etapie projektu. Wiadomym jest, że im większe wartości częstotliwości drgań własnych tym większa sztywność całej konstrukcji. W artykule sprawdzono w jaki sposób zmieniają się właśnie częstotliwości drgań własnych obiektu pod wpływem zmian w kształtowaniu modelu stropu konstrukcji. Głównym celem przeprowadzonych w artykule analiz było ustalenie zależności pomiędzy macierzami sztywności i mas a wynikami analizy modalnej wybranej konstrukcji. W artykule wysunięto hipotezę, wg której częstotliwości drgań własnych są odwrotnie proporcjonalne do masy stropu podniesionej do odpowiedniej potęgi. Wyprowadzony z tej zależności wzór został zweryfikowany na wielu wariantach modelu budynku wykonanym w programie do obliczeń numerycznych Dlubal.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.