Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  natężenie przepływu wody
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The dam of Beni Haroun is the largest in Algeria, and its transfer structures feed seven provinces (wilayas) in the eastern part of Algeria. Due to its importance in the region, it has now become urgent to study its watershed as well as all the parameters that can influence the water and solid intakes that come into the dam. The Soil and Water Assessment Tool (SWAT) model is used to quantify the water yields and identify the vulnerable spots using two scenarios. The first one uses worldwide data (GlobCover and HWSD), and the second one employs remote sensing and digital soil mapping in order to determine the most suitable data to obtain the best results. The SWAT model can be used to reproduce the hydrological cycle within the watershed. Concerning the first scenario, during the calibration period, R2 was found between 0.45 and 0.69, and the Nash–Sutcliffe efficiency (NSE) coefficient was within the interval from 0.63 to 0.80; in the validation period, R2 lied between 0.47 and 0.59, and the NSE coefficient ranged from 0.58 to 0.64. As for the second scenario, during the calibration period, R2 was between 0.60 and 0.66, and the NSE coefficient was between 0.55 and 0.75; however, during the validation period, R2 was in the interval from 0.56 to 0.70, and the NSE coefficient within the range 0.64–0.70. These findings indicate that the data obtained using remote sensing and digital soil mapping provide a better representation of the watershed and give a better hydrological modelling.
PL
Beni Haroun jest największym zbiornikiem zaporowym Algierii zasilającym w wodę siedem prowincji we wschodniej części kraju. Podjęcie badań jego zlewni oraz wszystkich czynników, które wpływają na dostawę wody i zawiesiny do zbiornika, okazało się pilne ze względu na regionalne znaczenie zbiornika. Model SWAT (Soil and Water Assessment Tool) wykorzystano do ilościowego ujęcia natężenia przepływu wody i identyfikacji wrażliwych elementów systemu z użyciem dwóch scenariuszy. W pierwszym wykorzystano dane światowe, w drugim dane z teledetekcji i cyfrowych map glebowych celem ustalenia najbardziej odpowiednich danych do osiągnięcia najlepszych rezultatów. Model SWAT można użyć do odtworzenia cyklu hydrologicznego na obszarze zlewni. Według pierwszego scenariusza podczas kalibracji R2 wynosił od 0,45 do 0,69, a współczynnik efektywności Nasha–Sutcliffa (NSE) mieścił się w przedziale od 0,63 do 0,80. Podczas walidacji R2 zmieniał się od 0,47 do 0,59, a współczynnik NSE od 0,58 do 0,64. Według drugiego scenariusza podczas kalibracji R2 wynosił od 0,60 do 0,66, a współczynnik NSE od 0,55 do 0,75. Podczas walidacji współczynniki mieściły się odpowiednio w granicach od 0,56 do 0,70 i od 0,64 do 0,70. Wyniki wskazują, że dane pozyskane z teledetekcji i cyfrowych map glebowych stanowią lepszą reprezentację zlewni i umożliwiają usprawnienie modelowania hydrologicznego.
2
Content available Experimental Study of Air Lift Pump Delivery Rate
EN
This paper presents analysis of results of investigations of flow rate of sand (Qs) and water (Qw) in an air lift pump. The investigations were performed on an air lift pump test rig, constructed in a laboratory on a scale of 1:1. The paper describes the construction and working principle of this air lift pump test rig and presents a methodology of derivation of empirical formulas for calculation of sand and water flow rate. A comparative analysis of the values of the sand and water flow rate obtained in direct measurements with analogical values of flow rate calculated with use of the derived empirical formulas was carried out. The research scope encompassed the derivation of the aforementioned empirical formulas in the PVC air lift pump with the internal diameter of the discharge pipe d = 0.03 m by the fixed sand-water mix delivery heads H: 0.40 m, 0.80 m, 1.20 m. To derive the empirical formulas for calculation of the sand and water flow rate, dimensional analysis and multiple regression was applied. In the air lift pump being tested, the water and sand flow rate felt along with the rise in the delivery head and the water flow rate was higher than the sand flow rate. Air pressure in such devices cannot be lower than 110 kPa and cannot exceed 150 kPa as for higher values of air pressure the sand and water flow rate starts to fall. The values of the sand and water flow rate calculated with use of the derived formulas coincide very well with the values determined from the direct measurements.
PL
W artykule przedstawiono analizę wyników badań natężenia przepływu piasku (Qs) i wody (Qw) w podnośniku powietrznym. Badania wykonywano na wybudowanym w laboratorium w skali 1:1 stanowisku do badania podnośnika powietrznego. W artykule przedstawiono budowę i zasadę działania stanowiska badawczego oraz omówiono metodykę wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody. Przeprowadzono analizę porównawczą wartości natężenia przepływu piasku i wody wyznaczonych z bezpośrednich pomiarów z wartościami obliczonymi za pomocą wyznaczonych empirycznych wzorów. Zakres badań obejmował wyprowadzenie wzorów do obliczania natężenia przepływu piasku i wody w podnośniku powietrznym z tworzywa sztucznego PVC o średnicy wewnętrznej rurociągu tłocznego d = 0,03 m, przy zadanej wysokości podnoszenia mieszaniny piasku i wody H: 0,40 m, 0,80 m, 1,20 m. Do wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W badanej konstrukcji podnośnika powietrznego wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody, natężenie przepływu piasku i wody malało, a wartości natężenia przepływu wody były większe w stosunku do wartości natężenia przepływu piasku. W badanym urządzeniu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 150 kPa, ponieważ przy wyższych ciśnieniach powietrza natężenie przepływu piasku i wody zaczynało spadać. Wartości natężenia przepływu piasku i wody obliczone za pomocą wyprowadzonych wzorów, bardzo dobrze pokrywały się z wartościami wyznaczonymi z bezpośrednich pomiarów.
EN
Water pump control methods are presented for the district heating system supplying an industrial heat user. The analysis aimed at determining optimum operating conditions for the system of pumps. The study focused on control parameters of the pumps installed at the heating substation delivering the heated water to the end-user. The chosen method consisted of throttling control of the pump using a control valve in the discharge header. The values of characteristic parameters and control characteristics of the pumps were used to evaluate the performance of the said pump system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.