Content available remote Design of a decentralised intelligent network for five wet pit pumping stations
EN
This paper presents a design for a decentralised intelligent network of five wet pit pumping stations in a rural area. This enables the network to automatically respond to inflow conditions divergent to the base flow and use the storage capacity of the system to prevent sewer overflows. First results for the base flow and a simulation of the network in EPANET are presented.
PL
W artykule przedstawiono projekt zdecentralizowanej inteligentnej sieci pięciu przepompowni mokrych położonych w obszarze wiejskim. Sieć umożliwia automatyczną reakcję w warunkach przypływu przekraczających wartość przy jętego natężenia przepływu ścieków, a jej pojemność magazynowa pozwala zapobiec przelewaniu się ścieków. Przedstawiono także pierwsze wyniki dotyczące natężenia przepływu ścieków oraz model sieci w EPANET.
2
Content available remote Ochrona zasobów wodnych poprzez dokładność pomiaru ilościowego ścieków
PL
Podstawowym stacjonarnym urządzeniem do pomiaru natężenia przepływu w kanalizacji są koryta zwężkowe. Zarówno polski katalog UNIKLAR-77, jak i międzynarodowe normy dotyczące koryt zwężkowych odnoszą się wyłącznie do koryt zwężkowych, w których wykonuje się pomiar wysokości napełnienia tylko w jednym przekroju pomiarowym, a mianowicie przed korytem. Pozwala to na dokładny pomiar, ale związane jest z wysokim ryzykiem przekroczenia zakresu pomiarowego i w rezultacie otrzymania błędnego wyniku. Porównano te rodzaje koryt zwężkowych z takimi, w których konieczne jest wykonanie pomiarów zarówno przed korytem, jak i w jego gardzieli.
EN
Flumes are the most commonly applied tools for measurements of flow rate through sewers. The Polish catalogue of flumes UNIKLAR-77 and some international standards refer solely to flumes in which only one measurement of flow depth is to be done. This measurement is made before a flume, which usually enables an accurate prediction of flow rate, but is associated with a high risk of being outside of appropriate flow rate range, resulting in false values. Some comparisons have been done between these two different kinds of flumes in which one, or two, flow depth measurements are necessary.
EN
This paper presents the results of dry weather flowrate studies in inflow and outflow channels of overflow structure PB-1. The facility is located in P.Skargi Street in Głogów. Based on the results the average daily peaking factor of dry weather sewage outflow was estimated. Low efficiency of the algorithm allows the estimation of the flow when depth of the channel is less then 20 cm and when it is not possible to perform measurements with the ultrasound probe. Pointed to inadequate reconstruction of cross-sectional shape of the channel during device configuration as the cause of getting inconsistent results. The results of corrective calculations based on Manning's formula and typical crosssections of channels were presented. Obtained results confirm the possibility of significant differences obtained when the channel parameters are configured incorrectly. Confirmed the low quality of the built-in algorithm supporting measurements at low depths, mistakenly called by the device manufacturer “Manning’s formula method”.
PL
W pracy przedstawiono wyniki badań natężenia przepływu ścieków pogody suchej w kanałach dopływowym i odpływowym z przelewu burzowego PB-1. Obiekt zlokalizowany jest przy ulicy P. Skargi w Głogowie. W oparciu o uzyskane wyniki oszacowano średni współczynnik dobowej nierównomierności odpływu ścieków pogody bezdeszczowej. Stwierdzono niską efektywność algorytmu umożliwiającego szacowanie natężenia przepływu w zakresie 0-20 cm napełnienia kanału, gdy nie jest możliwe wykonywanie pomiarów przy użyciu sondy ultradźwiekowej. Wskazano na mało dokładne odtworzenie przekroju kanału w czasie konfiguracji urządzeń jako przyczyny uzyskiwania sprzecznych wyników pomiarów. Zaprezentowano wyniki obliczeń korygujących wykonane w oparciu o wzór Manninga i typowe przekroje kanałów. Uzyskane rezultaty potwierdzają możliwość wystąpienia znaczących różnic uzyskiwanych przy nieprawidłowo skonfigurowanych parametrach kanału. Potwierdzono niską jakość wbudowanego algorytmu wspomagającego pomiary przy małych napełnieniach, błędnie nazywanego przez producenta urządzenia metodą Manninga.