Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  napięcie mięśniowe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote “Smart clothing” wearable for vital signs monitoring
EN
The authors of this article focused on monitoring body temperature, heart rate, and muscle tone. The ESP8266 microcontroller, SparkFUN MAX30105 heart rate monitor, MyoWearMuscle sensor, DS18B20 temperature sensor were used to produce the monitoring device for the abovementioned vital signs. The authors also performed tests of the developed solution. Tests of the constructed system showed the correct operation of the system. It should be borne in mind that the vital signs monitoring system presented in this article is only a prototype version, showing the possibilities and potential of the project.
PL
Autorzy niniejszego artykułu skupili się na monitorowaniu temperatury ciała , tętna oraz poziomu napięcia mięśniowego. Do wytworzenia urządzenia monitorującego wyżej wymienione parametry życiowe wykorzystano mikrokontroler ESP8266, pulsometr SparkFUN MAX30105, czujnik napięcia mięśniowego MyoWearMuscle sensor, czujnik temperatury DS18B20. Autorzy wykonali również testy wytworzonego przez siebie rozwiązania. Testy zbudowanego systemu wykazały poprawność działania systemu. Należy mieć na uwadze, że przedstawiony w niniejszym artykule system do monitorowania parametrów życiowych jest jedynie wersją prototypową, ukazującą możliwości i potencjał projektu.
PL
W artykule opisano podstawowe parametry życiowe człowieka takich jak: tętno, temperatura ciała, poziom napięcia mięśniowego, oddech i ciśnienie krwi. W artykule przedstawiono schemat blokowy oraz ideowy systemu monitorującego parametry życiowe wraz z algorytmem oprogramowania urządzenia. Przedstawiono przykładowe wyniki pomiarów.
EN
The article describes basic human life parameters such as: heart rate, body temperature, muscle tension, breathing and blood pressure. The article presents a block diagram and electrical diagram system for monitoring vital parameters along with the device software algorithm. Sample measurement results are presented.
PL
Celem pracy była elektromiograficzna ocena i porównanie aktywności bioelektrycznej wybranych mięśni układu stomatognatycznego dwóch osób dotkniętych dysfunkcją stawu skroniowo – żuchwowego (ang. temporomandibular disorders - TMD) o różnym stopniu nasilenia, oraz osoby zdrowej deklarującej brak objawów TMD.
EN
The aim of the study was an electromyography assessment and comparison of stomatognatic system’s selected muscles bioelectrical activity. The material consisted of two subjects who suffers from differential intensity of temporomandibular disorders (TMD) and the another one who’s healthy and doesn’t declare symptoms of TMD
PL
W artykule omówione zostały nowe metody poszukiwania przyczyn powstawania zdarzeń drogowych w kontekście stanu emocjonalnego kierowcy. Przedstawione badania dotyczą wpływu stanu huśtawki emocjonalnej na prowadzenie pojazdu. Analizy prowadzono na symulatorze jazdy z użyciem EMG (ElektroMioGrafia) jako miernika napięcia mięśniowego pojawiającego się w sytuacji stresu oraz GSR (Galvanic Skin Response) mierzącego elektryczne przewodzenie skóry. Dodatkowo mierzono puls kierowcy podczas jazdy. Wyniki wykazały, iż po wprowadzeniu w stan silnego pobudzenia emocjonalnego wzrasta napięcie mięśniowe w badanych obszarach a wraz ze wzrostem poziomu aktywacji układu współczulnego i emocji wzrasta krzywa GSR. Obydwa wyniki wskazują na fakt, iż w stanie huśtawki emocjonalnej obserwuje się zmiany pobudzenia mięśniowego i skórnego, na poziomie behawioralnym natomiast zwiększa się znacznie ryzyko spowodowania wypadku drogowego.
EN
Article provides an overview of new methods of searching for the causes of road accidents in the context of the emotional state of the driver. The research concerns the impact of the emotional swings of driving. Analysis was conducted in a driving simulator using EMG (electromyography) as a measure of muscle tone that occurs in situations of stress and GSR (Galvanic Skin Response) measures the electrical conductivity of the skin. In addition, heart rate was measured when driving. The results showed that after the introduction of a state of strong emotional arousal increases muscle tension in the studied areas, and with the increase in the level of activation of the sympathetic nervous system and emotions rising GSR curve. Both results show the fact that the swing state of emotional arousal show changes of muscle and skin, while at the behavioral level significantly increases the risk of causing a traffic accident.
PL
Napięcie mięśniowe jest zjawiskiem odruchowym powstającym w wyniku działania stale przypływających bodźców do mięśni. Wzmożone napięcie mięśniowe powstaje zarówno przy uszkodzeniach drogi piramidowej (spastyczność), jak i układu pozapiramidowego (sztywność). Wzmożone napięcie mięśniowe typu spastycznego stanowi poważny problem tak dla chorego, jak i dla lekarza. Ze względu na to, że spastyczność ujawnia się głównie w kończynach dolnych, chory ma trudności przede wszystkim z chodzeniem. Do tej pory nie opracowano dostatecznie wiarygodnej metody oceniającej wzmożone napięcie mięśniowe, a ocena subiektywna według skali Ashworth'a jest nieprecyzyjna. Dlatego tak istotnego znaczenia nabiera opracowanie obiektywnej metody pomiaru napięcia mięśniowego, która w sposób wiarygodny pozwoli monitorować m.in. skuteczność stosowanej terapii. Na podstawie założeń przedstawionych przez pracowników Katedry Chorób Układu Nerwowego Uniwersytetu Medycznego w Łodzi, w Instytucie Maszyn Przepływowych Politechniki Łódzkiej powstało urządzenie do pomiaru napięcia mięśni kończyn dolnych pacjentów ze schorzeniami układu nerwowego. W pracy przedstawiono dokładny opis i zasada działania urządzenia oraz przykładowe wyniki badań pacjentów z wzmożonym napięciem mięśniowym.
EN
The increased muscle tone is a result of damage of the piramidal tract (spasticity) as well as extrapiramidal system (rigidity). Spasticity is a serious problem both for a patient and a doctor. Due to the fact that spasticity is mainly observed in lower limbs, a patient has difficulty walking. Up to now there has been no sufficiently reliable method to assess the increased muscle tone. The subjective assessment using Ashworth scale is not precise. Therefore elaboration of an objective method for measurements of muscle tone is very important. Such a method should enable reliable monitoring of the treatment effectiveness. In cooperation with neurologists from the Department of Neurology and Epileptology of the Medical University of Lodz and engineers from the Institute of Turbomachinery of the Lodz University of Technology, there was invented a device to measure the spasticity of lower limbs of patients with nervous system diseases. In this paper a precise description and the principle of operation of this device are presented. An example of the investigation results for a patient with the increased muscle tone is also discussed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.