Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  multicommutation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The study deals with the application of multicommutation flow analysis for determination of Cr(III) concentration in environmental samples at a trace level. The detection method was based on the luminol-H2O2 chemiluminescence reaction in basic aqueous solution using Cr(III) ions as a catalyst. The experimental part of investigation focused on the optimization of equipment conditions, i.e. reagent flow rate, injected sample volume and the work of solenoid valves. The specificity of the method was tested with respect to selected heavy metal ions. The presented method allowed determination of Cr(III) over the range from 2.5 to 50ng*cm-3, with a low detection limit (under optimum conditions: 0.15ng*cm-3). Multicommutation is one of the best methods of analytical procedure automation. The main advantages of multicommutation method, compared with classical flow injection analysis (FIA), is the ability to achieve more repeatable analytical signal, which in turn allows to improve the method precision (relative standard deviation, RSD, was 1.8% for 10 determinations of 20ng*cm-3 Cr(III)). Moreover, it is excellent from the point of view of environmental protection because it offers very low reagent consumption: luminol 0.26; H2O2 2.16; sample 0.15 (cm3 per peak). The sampling rate was about 90 samples*h-1.
EN
A comparative study on analytical performance of a basic multi-commutated solenoid pump flow system (MPFS) and multi-commutated FIA system (MCFS) has been performed. Both flow systems utilised three-port solenoid valves acting as fluidic switches. The MCFS system was obtained by replacing a solenoid pump with a peristaltic pump, synchronized with valves, as a propelling unit. These two continuous flow strategies were applied to spectro-photometric determination of ammonium, nitrite, and phosphate in wastewater samples from urban wastewater treatment plant. Optimised peristaltic and solenoid pumped flow systems yielded similar results with respect to sensitivity', linear range . MPFS was. however, superior to MCFS in terms of day-to-day reproducibility (RSDs calculated for the slopes of 20 calibration curves obtained in different days were: , sample consumption (reduced twice for determination of ammonium and nitrite), and sample throughput . MPFS was advantageous with respect to versatility, possibility of miniaturisation, and increased simplicity due to reconfiguration of single-commutated elements without the need of physical reconfiguration of the flow manifold.
PL
Wykonano badania porównawcze sprawności analitycznej wielodrożnego przepływowego układu pompy solenoidowej (MPFS) i wielodrożnego układu wstrzykowej analizy przepływowej (MCFS). W obu układach zastosowano trójdrożne zawory solenoidowe działające jako przełączniki strumieniowe. Układ MCFS otrzymano przez zastąpienie pompy solenoidowej pompą perystaityczną, zsynchronizowaną/ zaworami, jako jednostką napędową. Te dwie strategie ciągłego przepływu zastosowano do spektrofotometrycznego oznaczania lonów amonowych, azotynów i fosforanów w próbkach ścieków z oczyszczalni miejskiej. Zoptymalizowane układy pompowe przepływu - perystaltyczny i solenoidowy dały podobne wyniki w odniesieniu do czułości, zakresu liniowości . MPFS był jednak lepszy niż MCFS w przypadku odtwarzalności z dnia na dzień (względne odchylenie standardowe obliczone dla 20 wykresów kalibracyjnych wyznaczonych w różnych dniach wynosiło: zużycia próbki (mniejszego dwukrotnie przy oznaczaniu NH4: i NO2 oraz liczby analiz (86 h-1 MPFS był również lepszy ze względu na wszechstronność, możliwość miniaturyzacji i większą prostotę - możliwość zamiany jcdnodrożnych elementów bez konieczności fizycznej rekonstrukcji przewodów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.