Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  multi-winding transformer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper, the problem related to transformation of ac voltage into DC voltage used in tram supply is considered. A variable component is always present in rectified voltage. Pulsation of rectified voltage is influenced by different factors. In a 12-pulse system, where two secondary transformer windings are used (one delta-connected and the other star-connected), an additional factor increasing the pulsation is the unbalance of the output voltages at these windings. Tap changer may be used and its setting is optimized here by applying the ant-colony algorithm. Different supply voltage variants have been considered. It is demonstrated that pulsation may be reduced by even 25%.
PL
W różnych obwodach elektrycznych wykorzystuje się napięcie stałe powstałe wskutek przetwarzania napięcia sinusoidalnego przemiennego dostarczanego przez sieć elektroenergetycznej. Są to układy różnych mocy, od pojedynczych W do MW. Zachodzi pytanie, jaki układ przetwarzania dobrać jako najefektywniejszy z technicznego i ekonomicznego punktu widzenia. W artykule skupiono się na układach przetwarzania 12- i 24-pulsowych, wykorzystujących wielouzwojeniowe transformatory prostowni-kowe. Przedyskutowano efektywność przetwarzania napięcia przy różnych wariantach napięcia zasilania i podano argumenty przemawiające za ograniczeniem się do przetwarzania 12-pulsowego.
EN
Different electric circuits use dc voltage created by transforming ac sinusoidal voltage supplied by the power grid. These are low- and high-power circuits, with power ranging from single watts to megawatts. The question arises what transforming system should be selected as the most efficient from technical and economical point of view. The authors have focused of 12- and 24-pulse systems utilizing multi-winding rectifier transformers. Effectivess of energy transformation has been discussed depending on the supply voltage variant. Authors have indicated that the 12-pulse system is in their opinion most advantageous.
EN
This paper aims to present a new equivalent scheme of multi-windings traction transformers, based on multiport purely inductive circuit. The mathematical background of this equivalent scheme is described. The determination of the different scheme elements is made through a finite-elements calculation of both main and leakage inductances, for the case of a four-winding transformer. A procedure is defined, which allows to estimate the values of these elements from some measurements on the transformer at no-load and short-circuit operations. A specific strategy of short-circuit tests is described, allowing to determine all parameters in a rather simple way.
EN
This paper aims to present a new equivalent scheme of multi-windings traction transformers, based on multiport purely inductive circuit. The mathematical background of this equivalent scheme is described. The determination of the different scheme elements is made through a finite-elements calculation of both main and leakage inductances, for the case of a four-winding transformer. A procedure is defined, which allows to estimate the values of these elements from some measurements on the transformer at no-load and short-circuit operations. A specific strategy of short-circuit tests is described, allowing to determine all parameters in a rather simple way.
EN
This paper deals with the saturation in magnetic core of a multi-winding transformer which supplies nonlinear passive load. Such systems are often a part of OC-OC converters. In order to investigate the saturation phenomenon in multi-winding transformers, a laboratary transformer was build. Analysis of time responses measured during different experiments performed on the transformer was used to explain the phenomenon in the terms of physics. It represents theoretical background for prevention of magnetic core saturation in systems with multi-winding transfonners.
PL
W artykule rozważono nasycenie rdzenia magnetycznego transformatora wielouzwojeniowego z nieliniowym pasywnym obciążeniem. Taki układ występuje często w przekształtnikach staloprądowych. W celu przebadania zjawiska nasycenia zbudowano transformator laboratoryjny. Analizy przebiegów czasowych mierzonych podczas różnych eksperymentów pozwalały na wyjaśnienie fizycznej natury zjawiska, co z kolei, jest podstawą do ochrony rdzenia wielouzwojeniowego transformatora przed nasyceniem.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.