Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  multi-terminal network
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper investigates a control structure to enhance the DC fault ride-through capability of a full-bridge modular multilevel converter (MMC) station, while ensuring a stable controlled operation as a STATCOM during DC faults without the need for fault isolation. Taking advantage of the switching states of a full-bridge submodule, a DC current controller is proposed, which provides the DC voltage reference for the modulation when a DC fault is detected. By changing the outer controllers strategy from DC voltage or active power control to converter energy control during a fault, the decoupling of the converter operation from the DC side dynamics is realized. In this paper, the focus is on the control methodology at all times of operation and the evaluation of the STATCOM control during a fault. To this end, extensive simulations were performed on a three-terminal high voltage direct current (HVDC) grid in radial configuration and a pole-to-pole DC fault case was investigated. The results showed that the AC voltage and current were controlled within limits at all times, while the full-bridge MMC was able to provide reactive power support to the AC grid. Moreover, using the proposed control methodology, the transients at the operation transition points between STATCOM and inverter/rectifier operation were minimized and the stations were able to safely ride through the fault.
EN
Electrical Impedance Tomography (EIT) aims to study the conductivity/permittivity distribution of the interested field. The distributed parameters can be analyzed with electromagnetic field based Finite Element Method (FEM). Because only the lumped circuit parameters can be measured by the data acquisition unit, the multi terminal network modals of the sensitive field with common node and common loop topology are introduced. By analyzing the inherent relationships of different excitation strategies, the number of independent measurements is calculated and an optimum single source excitation mode, quasi opposite excitation, that has the advantages of more uniform sensitive distribution and more independent measurements, is proposed.
PL
Elektryczną tomografię impedancyjną (ETI) stosuje się wówczas, gdy istnieje konieczność zbadania obszaru, który zawiera materiał o właściwościach przewodzących i dielektrycznych. Parametry charakterystyczne dla tego obszaru mogą być analizowane przy zastosowaniu pola elektromagnetycznego i metody elementów skończonych (MES). Z tego powodu, że układy pomiarowe ETI są zdolne mierzyć jedynie globalne parametry obwodu, zastosowano metodę sieci wielopołączeniowych i topologię wspólnej pętli. Poprzez analizę istniejących powiązań w różnych strategiach pomiarowych uzyskano zbiór danych pomiarowych i zaproponowano tryb pomiarowy oparty na jednym źródle energii oraz tryb pomiarowy oparty na quasi-przeciwnym źródle energii. Zaproponowane rozwiązania pozwoliły uzyskać bardziej jednorodny rozkład wrażliwości wewnątrz obszaru pomiarowego i zbiór niezależnych liniowo danych pomiarowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.