EN
The paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism of sorts in which a signal proportional to the saturated control reference is subtracted from the error signal in each reference frame. The fundamental harmonic filter based on the DFT algorithm with phase correction is used for grid synchronization and current harmonic detection. Three configurations of the 15 kVA converter were tested experimentally and then compared: the 18-pulse diode rectifier with and without an additional grid reactor, and the rectifier integrated with an active power filter. The applied control method of active filter significantly reduces harmonic distortion and unbalance of the grid current, which is particularly advantageous under non-ideal supply voltage and low loads conditions.
PL
W artykule przedstawiono system sterowania oraz wybrane wyniki badań eksperymentalnych przekształtnika AC / DC składającego się z osiemnastopulsowego diodowego prostownika na bazie dławików sprzężonych i szeregowego energetycznego filtra aktywnego. Przebadano i porównano trzy konfiguracje przekształtnika o mocy 150kVA: (1) osiemnastopulsowy prostownik bez dodatkowych elementów, (2) prostownik z dodatkowym dławikiem sieciowym oraz (3) prostownik zintegrowany z szeregowym filtrem aktywnym. Zastosowana metoda sterowania filtrem aktywnym znacznie zmniejsza zniekształcenia harmoniczne oraz asymetrię prądów sieci, co jest szczególnie korzystne w przypadku niskich obciążeń i nieidealnego napięcia zasilającego.
EN
The paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The highest current harmonic distortion and asymmetry exists for individual operation of the rectifier. Connecting a supplementary grid reactor to a rectifier significantly reduces harmonic distortion and unbalance of the grid current, especially in the nominal load conditions. The 18-pulse diode rectifier integrated with S-APF outperforms other configurations in grid current balancing and harmonic suppression, which is particularly advantageous at low loads and non-ideal supply voltage. The integrated system has additional features like dc voltage regulation, low susceptibility to supply asymmetry and load changes.
3
PL
W artykule przedstawiono zasadę działania oraz wyniki wybranych badań symulacyjnych i laboratoryjnych układu przekształtnika 18- pulsowego o wyjściu stałonapięciowym, współpracującego z szeregowym filtrem aktywnym małej mocy (APF). Prezentowany system pozwala znacznie zredukować, szczególnie w przypadku autonomicznej sieci zasilającej, niepożądane wyższe harmoniczne w przebiegu prądu sieciowego. Osiemnastopulsową pracę przekształtnika osiąga się dzięki zastosowaniu zestawu sieciowych trójfazowych dławików sprzężonych (WPP i TDS). Jednoczesne zastosowanie dławików magnetycznie sprzężonych i szeregowego filtra aktywnego małej mocy, pozwala na osiągnięcie niewielkim kosztem, zmniejszenia współczynnika THD prądu zasilającego, do wartości odpowiadającej warunkom CPC (Clean Power Converters).
EN
The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse converter system with direct voltage output, cooperating with a small series active power filter (APF). The presented system makes it possible to reduce, especially in autonomous supply networks, undesired higher harmonics in the network current. The 18-pulse nature of operation of the converter is reached using a set of coupled three-phase network reactors (WPP and TDS). Simultaneous use of the magnetically coupled reactors and the small active power filter provides opportunities for easy and cheap reduction of the supply current THD coefficient, down to the values acceptable by clean power converters (CPC) conditions.