Monitoring of activated sludge flocs may provide important information for effective operation and control of wastewater treatment. The research objective is to demonstrate methodology for activated sludge image processing aimed to describe morphological characteristics of activated sludge flocs. The proposed software- -based method was presented and verified by analysis of several activated sludge samples. The results show high efficiency of image segmentation and floc recognition of more than 94% floc components. The analysis of a series of 50 pictures gives rapid and reliable results and can be performed in an automatic or semiautomatic mode. Given inherent heterogeneity of activated sludge flocs, multiple and repeated sample images capture (processing of 50 pictures at a time, repeated at least 4 times ) is recommended.
PL
Analiza mikroskopowa osadu czynnego może dostarczyć ważnych informacji dla prawidłowego funkcjonowania i kontroli oczyszczania ścieków. Celem badań jest przedstawienie procedury przetwarzania i analizy obrazów osadu czynnego zmierzające do opisania cech morfologicznych kłaczków. Program DAIME użyto do oceny parametrów kłaczków osadu czynnego. Proponowana procedura wykorzystania tego programu została przedstawiona i zweryfikowana poprzez analizę kilku próbek osadu czynnego w maksymalnie 6 powtórzeniach. Każda seria składała się z 10 do 70 obrazów. Analizowane kłaczki zliczono a wyniki zmierzonych parametrów morfologicznych kłaczków poddano analizie statystycznej. Wyniki przetwarzania obrazu zostały pokazane jako prezentacja obrazów z kolejnych kroków analizy. Wyniki pomiarów parametrów morfologicznych wskazują na wysoką efektywność segmentacji obrazu i rozpoznawania kłaczków wynoszącą ponad 94%. Wielkość kłaczków została wybrana spośród dostępnych parametrów, aby pokazać ile obrazów należy poddać obróbce i w ilu powtórzeniach wykonać analizę, aby uzyskać wiarygodne wyniki analizy. Program DAIME umożliwia dobrą segmentację i nadaje się do przetwarzania i pomiar parametrów morfologicznych kłaczków osadu czynnego. Analiza serii składającej się z 50 zdjęć jest szybka, może być automatyczny lub półautomatyczny, a daje wiarygodne wyniki. W świetle heterogeniczności osadu czynnego zalecane jest wykonanie ponad 4 powtórzeń (czterokrotne przetwarzanie co najmniej 50 zdjęć).
PL
Końcowy efekt oczyszczania biologicznego ścieków w znacznej mierze zależy od skuteczności oddzielania osadu czynnego od oczyszczonych ścieków. Właściwości sedymentacyjne osadu czynnego związane z wielkością, kształtem i gęstością kłaczków mogą ulec pogorszeniu w wyniku nadmiernego rozrostu bakterii nitkowatych lub kumulacji zewnątrzkomórkowych polimerów o znacznym uwodnieniu. W poszukiwaniu działającego wybiórczo i bezpiecznego dla środowiska środka redukującego liczebność organizmów nitkowatych przebadano wpływ biosurfaktanta Reco 10 na morfologię osadu czynnego. Bezpośrednio po wprowadzeniu roztworów biopreparatu do zawiesiny osadu czynnego nie wystąpiły zmiany w indeksie objętościowym osadu. Jednak po 24 godzinach inkubacji liczebność bakterii nitkowatych w kłaczkach osadu czynnego zmniejszyła się w porównaniu z kontrolą o 39 do 67% w zależności od stężenia środka powierzchniowo czynnego. Przy stężeniach 20 i 50 mg dm–3 biopreparatu obserwowano prawie 20% spadek aktywności oddechowej osadu mierzonej na podstawie ilości wydzielonego CO2. Mimo tego hamującego aktywność oddechową działania, po 24 godzinach od dodania Reco 10 morfologia osadu czynnego uległa wyraźnej poprawie. Zaobserwowano poprawę spójności kłaczków, wzrost ich gęstości i regularności kształtów, mimo zmniejszenia średnich rozmiarów skupisk nawet o odpowiednio 21 i 17% nie doszło również do zaniku mikrofauny.
EN
The final effect of biological treatment plant operation depends on the separation efficiency of the activated sludge from treated wastewater. Sludge sedimentation properties related to size, shape and density of flocs, may be deteriorated as a result of excessive growth of filamentous bacteria or accumulation of hydrated extracellular polymers. In search of selectively and environmentally safe substances able to reduce the size of filamentous organisms the impact of biosurfactant Reco 10 on the morphology of activated sludge was examined. Immediately after application of surfactant into the activated sludge suspension, there were no changes in the index of sludge volume. However, after 24 hours of incubation, the number of filamentous bacteria per activated sludge flock decreased by 39 to 67% depending on the surfactant concentration. At concentrations 20 and 50 mg · dm–3 of Reco 10 almost 20% inhibition of respiration calculated on the base of the increase of CO2 concentration was observed. Nevertheless after 24 hours of incubation with 10 Reco the activated sludge morphology (the increase of cohesion, density and regularity of flocs shape) has been significantly improved, despite a reduction in medium-sized clusters of up to 21 and 17%. No losses of microfauna (protozoa and rotifers) were observed. The results confirm that it is possible to use biodegradable surfactant to improve the structure of activated sludge.
EN
In this study the effect of anionie surfactants on the morphology of activated sludge floes and biomass activity is quantitatively described. Three anionie surfactants: sodium dodecyl sulphate, sodium alkylbenzene sulphonate and sodium alkyltrioxyethylene sulphate were tested. The batch experiments were performed for a wide range of initial concentrations of anionics in wastewater from 2.5 to 2500 mg-dnr'. In spite of different chemical structure the action of all tested anionie surfactants resulted in the decrease of activated sludge floes dimensions ai the similar level. It occurred that in the range of anionics concentrations, which are typical for domestic wastewater (2.5-25 mg-dnr'), they contributed to the decrease of mean projected area of floes by about 30%, whereas at the concentrations of 250 and 2500 mg-dnr1 mean projected area decreased usually by 50-60%. Sodium alkylbenzene sulphonate exerted the strongest inhibition etTect on dehydrogenase activity of activated sludge biomass. This effect coincided with the decreased degrees of removal for this surfactant and its biodegradation products, especially at its lower initial concentrations in wastewater.
PL
W niniejszej pracy przedstawiono w ujęciu ilościowym wpływ anionowych środków powierzchniowo czynnych (ASPC) na morfologię kłaczków osadu czynnego i aktywność biomasy. Obiekt badań stanowiły trzy anionowe surfaktanty: dodecylosiarczan sodu, alkilobenzenosulfonian sodu i alkilotrioksyetylenosiarczan sodu. Doświadczenia przeprowadzono w układzie okresowym w szerokim zakresie stężeń ASPC w ściekach od 2,5 do 2500 mg dm'. Wszystkie trzy badane surfaktanty przyczyniały się do zmniejszenia wielkości kłaczków osadu czynnego na podobnym poziomie, pomimo odmiennej budowy chemicznej. Średnia powierzchnia rzutu kłaczków zmniejszała się pod wpływem surfaktantów o około 30%, kiedy stężenie ASPC w ściekach wynosiło od 2,5 do 25 mgdm' i o 50-60% przy stężeniu ASPC w ściekach 250-2500 mgdnr3. Alkilobenzenosulfonian sodu najsilniej inhibitował aktywność dehydrogenazową biomasy osadu czynnego. Towarzyszył temu niższy, w porównaniu do pozostałych badanych ASPC, stopień usunięcia lego surfaktanta i produktów jego rozkładu ze ścieków, zwłaszcza w niższym zakresie jego początkowych stężeń w ściekach.