A variety of tool shoulder designs comprising three families i.e. blade, spiral and circular shaped scrolls, were produced to improve the material flow and restrictions to avoid the tunnel void. The bobbin tools were manufactured by 3D printing additive manufacturing technology using solid filament. The butt weld joint was produced by each tool using plasticine as the workpiece material. The apparent surface features and bi-colour cross-sections provided a physical flow comparison among the shoulder designs. For the bobbin friction stir welding (BFSW), the tool shoulder with a three-spiral design produced the most stability with the best combination of the flow patterns on surface and cross-sections. The circular family tools showed a suitable intermixing on the surface pattern, while the blade scrolls showed better flow features within the cross-sections. The flow-driven effect of the shoulder features of the bobbin-tool design (inscribed grooves) was replicated by the 3D-printed tools and the analogue modelling of the weld samples. Similar flow patterns were achieved by dissimilar aluminium-copper weld, validating the accuracy of the analogue plasticine for the flow visualization of the bobbin friction stir welding.
EN
The flow-inducing effect of the bobbin-tool features (tri-flat pin and scrolled shoulder) were replicated by a simple analogue model for aluminium welds by layered plasticine samples. Flow patterns of the weld zone were clarified by a typical stereomicroscopy instrument assisted by dark-field/bright-field illumination. The effects of the pin features, specifically threads and flats in centre of bond zone and scrolled shoulder in sides of stirred zone, were identified. This study shows that internal flow features for BFSW welds is transferable from the friction stir welding process to the functional metal forming processes such where the shearing can extensively affect the microstructure. The similarity between the flow pattern of the provided aluminium samples and the plasticine analogue can validate the accuracy of the flow model presented in this work.
PL
Podczas projektowania układów izolacyjnych urządzeń elektroenergetycznych koniecznym jest określenie wartości maksymalnych oraz roboczych natężenia pola elektrycznego. Równocześnie, dąży się zwykle do tego, aby uzyskane rozkłady natężenia pola elektrycznego były zbliżone do równomiernego. Analiza rozkładu natężenia pola w izolacji urządzenia pozwala na ocenę poprawności projektu jego konstrukcji oraz na optymalizację parametrów wpływających na ten rozkład. Artykuł przedstawia zastosowanie analogowych i numerycznych metod modelowania rozkładu natężenia pola elektrycznego dla analizy układów izolacyjnych wybranych urządzeń elektroenergetycznych: kabla 3-fazowego SN oraz stojana maszyny elektrycznej. Porównano i poddano dyskusji wyniki uzyskane dwiema metodami wyznaczania rozkładów natężenia pola elektrycznego, występującego w warunkach eksploatacji, w wybranych układach izolacyjnych: 1) metodą modelowania analogowego z digitalizacją wyników; 2) symulacji numerycznych opartych na metodzie elementów skończonych (MES). Obie metody mają znaczny potencjał edukacyjny i są stosowane podczas zajęć dydaktycznych dla studentów studiów inżynierskich na kierunku Elektrotechnika.
EN
The permissible value of the operating field strength is a fundamental requirement for the selection of high voltage equipment. It determines the electrical strength of insulating materials used in insulating systems and the effects of various operating stresses. By determining the distribution of the electric field intensity in the tested insulation system, the maximum value of the electric field strength is obtained. The knowledge of the electrical field strength distribution E is also necessary during laboratory tests on new insulating systems. The article presents a description of a laboratory stand used to determine the distribution of electric field strength in several typical insulation systems, the results of measurements during the exercise, and the description and results of the computer simulation of electrical field strength E in the model insulation.
4
Content available remote Modelowanie analogowe w analizie jakościowej rozchodzenia się drgań
PL
Proces rozprzestrzeniania się drgań zachowuje się analogicznie jak inne znane zjawiska podobne do niego, np. zjawisko drgań układów elektrycznych, mechanicznych, hydraulicznych, zjawisko dyfuzji, zjawisko rozchodzenia się ciepła, zjawisko falowe, czy zjawisko adwekcji. Do analizy problemu zostaną wykorzystane zjawiska podobne i uogólnione układy dynamiczne. Da to możliwość wyciągania wniosków co do zachowania się jednego procesu na podstawie innego, podobnego do niego. Taka koncepcja zostanie wykorzystana przy analizie jakościowej rozchodzenia się drgań, w szczególności w gruncie, czy podłożu gruntowym inżynierskich obiektów transportowych.
EN
The theory of dynamic systems is usually used to model the real systems. The models are based on solving ordinary differential equations, partial or difference, which enable obtaining the relation between input signal and the system response (output signal). The analogy between those models and generalized dynamic systems or control systems can be practically used. Vibration propagation can be described in a similar way as the phenomena of vibrations of the electrical, mechanical, or hydraulic systems, diffusion, heat propagation, wave propagation or advection. the physical problem will be solved based on generalized dynamic systems, which enables drawing corresponding conclusions. This concept will be applied to qualitative analysis of vibration propagation in the foundations of transportation constructions.
EN
The aim of this paper is to introduce a matrix approach for approximate solving of non-commensurate fractional variable order linear control systems in state-space form. The approach is based on switching schemes that realize variable order derivatives. The obtained numerical solution is compared with simulation and analog model results.
PL
Dotychczasowe badania terenowe w polskich Karpatach zewnętrznych prowadzone przez różnych badaczy dokumentują obecność utworów chaotycznych, które powstały w wyniku podmorskich ruchów masowych. Wychodnie utworów chaotycznych często występują w rejonie stref ścięć tektonicznych i mają charakter melanży tektonicznych związanych z nasunięciami. Wykorzystując metodę modelowania analogowego, przeprowadzono eksperyment dokumentujący sposób powstawania kompleksów chaotycznych w rejonie nasunięcia.
EN
Previous fieldwork in the Polish Outer Carpathians conducted by various researchers document the presence of chaotic complexes, the blocks in the matrix type, which were created as a result of underwater mass movements. The outcrops of the chaotic complexes frequently occur in the region of tectonic shear zones and are characteristic for tectonic mélanges connected with overthrusts. Using the analog modelling method, the experiment was performed documenting how the chaotic complexes are formed in the region of the overthrust.
PL
Przedstawiono stanowisko laboratoryjne przeznaczone do modelowania analogowego układów regulacji automatycznej. Stanowisko to złożone jest z elektronicznej maszyny analogowej MA-10 i sterownika programowalnego PLC. Zaproponowa-no metodę wyznaczania modelu analogowego dla układów regulacji procesówtechnologicznych.
8
Content available remote Analog modelling of overvoltages in transformer with MO-surge arrester
EN
Power transformers are usualy protected against overvoltages occurring in power system by means of metal oxide (MO) surge arresters. Generally, MO-surge arresters are installed outside of power transformers and are connected at the source side. Moreover, they may be connected in parallel with the tap of transformer winding and placed inside the transformer tank. It is very important for designers to know the influence of MO-surge arresters on the distribution of overvoltages inside the protected transformer. Analysis of the influences of MO-surge arresters is based on the theoretical calculations as well as using of an analog model. In this paper the results of analog investigations in the transformer with surge arrester have been presented. The Iow voltage metal oxided varistor has been connected to different selected paits of real power transformer winding. The model external voltage wave has been generated. Thus, the standard lightning wave of 1,5 kV and the sinusoidal non-dumped voltage with amplitudę of 0,6 kV with various freąuencies ranging from 2 kHz to 25 kHz have been used for investigations.
PL
Transformatory są zabezpieczane przed przepięciami, występującymi w układzie elektroenergetycznym, przy zastosowaniu ograniczników przepięć z tlenków metali. Zasadniczo ograniczniki przepięć są instalowane na zewnątrz transformatorów i łączone od strony zasilania. Mogą one być również łączone równolegle z fragmentami uzwojeń i umieszczane wewnątrz kadzi. Poznanie wpływu ograniczników na przepięcia wewnątrz transformatorów jest bardzo ważne dla projektantów. Może on być analizowany na podstawie obliczeń jak również przy zastosowaniu modelowania analogowego. W artykule przedstawiono rezultaty analogowych badań przepięć w transformatorze z ogranicznikiem. Niskonapięciowy warystor z tlenków metali łączono z wybranymi fragmentami uzwojeń transformatora. Badania wykonano przy zastosowaniu znormalizowanego napięcia piorunowego o amplitudzie 1,5 kV oraz nietłumionej fali sinusoidalnej o amplitudzie 0,6 kV i częstotliwości z przedziału od 2 kHz do 25 kHz.