Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  model układu krążenia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the results of research focused on the adaptation of a hybrid simulator of the human circulatory system to the physical reproduction of the haemodynamic conditions prevailing in the apex of the heart. This report describes the principle of operation of the hybrid simulator and presents two methods of its modification. The work includes analysis of the algorithm verification and describes problems that appeared during research. A comparison of the results obtained for both modification methods is shown, as well as preliminary simulation results for a constant-flow ventricle assist device joined to the hybrid simulator operating in the apex of the heart-aorta configuration.
2
Content available Wybrane przykłady modelowania biomedycznego
PL
W publikacji przedstawiony został przegląd metod modelowania i przykładowych modeli biomedycznych. Przybliżono tu specyfikę, budowę, opis działania oraz zastosowania poszczególnych modeli. Opisano między innymi model układu oddechowego, model układu krążenia, model "wirtualnego pacjenta" podczas terapii nerkozastępczej, model filtracji Dead End Procedure (D.E.). Omówiono również korzyści płynące ze stosowania modeli biomedycznych.
EN
Review of a number of modelling methods as well as examples of biomedical models mathematical and physical was presented in this publication. Specificity, structure, working and applications of particular models can be found in the text. The model of respiratory system, circulatory system, "virtual patient" during renal replacement therapy, and Dead End Procedure (D.E.) plasma fractionation were described. The benefits of application of biomedical models were also showed.
EN
The choice of control strategy of a Left Ventricle Assist Device in heart recovery is an open problem. It affects circulatory parameters, myocardial perfusion and energetic variabies, directly related to oxygen consumption in both ventricles. The experiments were performed by a computer controlled closed loop mock circulatory system, in known and constant pathological condition, connected to a pneumatic LVAD. The assistance was realized by changing artificial left ventricular systole duration and its relation to the QRS complex of ECG signal. The data were analysed as a function of haemodynamic parameters as well as energetic variabies (external work EW, oxygen consumption V0(2), cardiac mechanical efficiency CME). The results have shown: 1) assistance effect, besides driving pressure of the artificial ventricle, depends on its systole beginning and duration and on the value of peripheral resistance; 2) left heart assistance influences right ventricular parameters in limited way; it increases right atrial pressure and decreases arterial pulmonary pressure and oxygen consumption.
PL
Wybór strategii sterowania urządzenia wspomagającego LVAD dla poprawy kondycji niewydolnego serca jest problemem otwartym. Proces wspomagania oddziaływuje na parametry cyrkulacji, perfuzję mięśnia sercowego i parametry energetyczne związane bezpośrednio ze zużyciem tlenu przez obie komory serca. Opisane w niniejszej pracy eksperymenty przeprowadzono na sterowanym komputerowo fizycznym modelu układu krążenia, na którym zamodelowano stany patologiczne, poddane następnie wspomaganiu kontrpulsacyjnemu za pomocą urządzenia LVAD. W procesie wspomagania zmieniano czas trwania fazy skurczu sztucznej lewej komory urządzenia LVAD poprzez zmianę opóźnienia końca fazy skurczu tej komory względem zespołu QRS przebiegu EKG "sztucznego pacjenta". Opóźnienie początku fazy skurczu sztucznej komory pozostawało nie zmienione. Uzyskane wyniki analizowano na gruncie hemodynamicznym (ciśnienia, przepływy) i energetycznym (praca zewnętrzna EW, zużycie tlenu V0(2), współczynnik wydajności mechanicznej serca CME). Stwierdzono: 1) na efektywność wspomagania, oprócz ciśnienia sterującego pracą sztucznej komory, wpływa czas trwania jej fazy skurczu i czas opóźnienia względem zespołu QRS oraz wielkość oporności peryferyjnej; 2) wspomaganie lewej komory wywiera ograniczony wpływ na prawe serce, co się objawia niewielkim wzrostem ciśnienia w prawym przedsionku i pewnym spadkiem ciśnienia arterialnego płucnego oraz zużycia tlenu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.