In the paper an experiment is described, designed and conducted to verify hypothesis that neural networks of relatively small size can provide relevantly accurate approximation of unknown analytical solution of the two-compartment hemodialysis model with variable volume of the extracellular compartment. The experiment was based on a thousand pseudorandomly generated sessions. The concentration values at the end of treatment and the equilibrated Kt/V index were approximated with absolute relative error less or equal 2% for around 90% values, with only 8 or 12 hidden neurons. Such results have been considered to confirm the main hypothesis.
PL
W artykule opisano eksperyment, zaprojektowany i zrealizowany w celu zweryfikowania hipotezy, że relatywnie nieduża sieć neuronowa może zapewnić odpowiednio dokładną aproksymację nieznanego rozwiązania analitycznego dla modelu dwuprzedziałowego ze zmienną objętością przedziału zewnątrzkomórkowego. Eksperyment bazował na tysiącu pseudolosowo wygenerowanych sesji. Wartości stężeń w chwili zakończenia zabiegu oraz indeks Kt/V dla uśrednionego stężenia były oszacowane z dokładnością modułu błędu względnego mniejszą lub równą 2% dla około 90% wartości, przy zaledwie 8 lub 12 neuronach w warstwie ukrytej. Wynik ten uznano za potwierdzający prawdziwość postawionej hipotezy.
PL
W artykule zaproponowano uproszczoną strukturę modelu przepływowego hemodializy, zbliżoną do klasycznego modelu dwuprzedziałowego. W celu przeprowadzenia obliczeń porównawczych umożliwiających ocenę przydatności nowego modelu opracowano metodykę pseudolosowego generowania danych symulujących zabieg dializy. Dla wytworzonego w ten sposób zbioru danych testowych, N — 1000 wykazano, iż oba modele - proponowany i klasyczny - wykazują podobną zdolność odtwarzania zadanych przebiegów stężeń. Dla opisanych wyżej danych wyznaczono zależność między najważniejszymi parametrami obu modeli, wykazując możliwość ich łatwego przeliczania. Wskazano jednak także na pewne różnice w przebiegach uzyskanych za pomocą obu modeli, co stanowi uzasadnienie dalszego badania modeli przepływowych.
EN
In the paper a simplified blood flow model of hemodialysis is sugested, being a modified version of the classical two-compartment model. A method of pseudorandom hemodialysis data generation has been designed to enable relevant comparative study of both models. For such test data, N = 1000, it has been shown that the flow model has very similar capability of modeling the concentration runs, as the classical two-compartment model. For the randomly generated data, the mutual relationship between the crucial model parameters has been shown. Such property makes the convertion between discussed models very simple. However, some differences in the runs obtained from both models were also indicated, which encourages further investigation of the blood-flow models.
PL
W artykule opisano wielostopniową procedurę optymalizacyjna, opracowaną specjalnie na potrzeby wyznaczania klirensu komórkowego na podstawie danych pomiarowych, zebranych w czasie zabiegu hemodializy. Iteracyjny charakter procedury umożliwia nieznaczne optymalizacyjne korygowanie wartości generacji mocznika i recyrkulacji. Opis zilustrowano przykładowymi oraz zbiorczymi wynikami. Zaproponowana metoda okazała się zbieżna dla danych z 91 dializ, wprowadzając błąd względny dla mierzonego stężenia w przedziale zewnętrznym o wartości średniej 0,51% przy odchyleniu standardowym 2,80%.
EN
In the paper a multistage optimization procedure has been proposed. The technique had been designed to make possible the computation of the cellular clearance based only on the data measured during hemodialysis treatment. The iterative structure of the proposed algorithm allows subtle corrections on the values of the urea generation and recirculation. The description has been illustrated with some resulting examples and also with the summary data. The technique proved to be convergent for measurements performed during 91 dialysis sessions, while introducing the relative error into modelled external compartment urea concentration with the mean value 0.51% and standard deviation 2.80%.