EN
Extensive aerosol particle concentrations are one of the factors contributing to poor air quality in cities. The aim of this study is to assess particle number and mass concentrations on a road in Lublin, Poland, in peak and off-peak traffic hours and its impact on the particle exposure for commuters and pedestrians. Mobile monitoring and fixed-site measurements on the sidewalk along the established 2.1 km long route were conducted with the use of Mobile Air Pollution Analytic Laboratory equipped, among other things, with instruments measuring the real-time number and mass concentrations of particles with size range from 10 nm to 32 μm. The highest average concentrations of ultrafine particle number PN0.1 (25.4 ±11×103 pt/cm3; mean ± standard deviation), total particle number PN (29.2 ±12×103 pt/cm3) as well as mass concentrations of PM2.5 (29.1 ±7.6 μg/m3) and PM10 (45.4 ±10.3 μg/m3) were obtained in peak traffic hours for the part of the route with the most intensive traffic. The average particle number concentrations for the entire route and the part of route with the most intensive traffic in peak times were found to be about 3 to 4 times higher than in off-peak times. The average particle mass concentrations were about twice as high. Furthermore, the average values of the examined particle number and mass concentrations were higher for the on-road measurements than for fixed-site measurements. Moreover, a greater percentage of ultrafine particles was observed during mobile monitoring than in the fixed-site measurement points. It was established that a greater number and mass of particles, irrespectively of their size range, is deposited in the respiratory tract of commuters and pedestrians in peak hours than in off-peak hours. In peak times the average particle doses received by commuters and pedestrians equaled 4.8 ±2.4×109 pt/h or 29.6 ±10.7 μg/h (PM10) and 4.2 ±2.3×109 pt/h or 29.6 ±8.6 μg/h (PM10), respectively. Additionally, in both peak and off-peak hours greater particle doses were determined in the considered part of the route with the most intensive traffic; however, in off-peak traffic times pedestrians are more exposed to traffic-related pollutants than commuters. Overall, the obtained results reflect the importance of traffic-related particle emission measurements for exposure evaluations and the need of taking the actions aimed at decreasing it.
PL
Celem pracy było określenie stężenia liczbowego i masowego cząstek na wybranych ulicach Lublina w godzinach szczytu oraz poza szczytem, a także ocena narażenia kierowców i pieszych na ich oddziaływanie. W ramach badań przeprowadzono zarówno pomiary mobilne, jak i stacjonarne w określonych punktach pomiarowych na trasie o długości 2,1 km. Mierzono w czasie rzeczywistym między innymi stężenia liczbowe i masowe cząstek o rozmiarach w zakresie od 10 nm do 32 μm. Najwyższe średnie koncentracje ultradrobnych cząstek PN0.1 (25,4 ±11×103 #/cm3) oraz koncentracje całkowitej liczby cząstek PN (29,2 ±12×103 #/cm3), a także stężenia masowe PM2.5 (29,1 ±7,6 μg/m3) oraz PM10 (45,4 ±10,3 μg/m3) rejestrowano w godzinach szczytu na wydzielonym odcinku trasy o największej intensywności ruchu. Średnie koncentracje cząstek mierzone w godzinach szczytu dla całej trasy oraz dla wydzielonego odcinka były, w zależności od wielkości cząstek, ok. 3-4 razy większe w porównaniu do wyników pomiarów dla godzin pozaszczytowych. Z kolei średnie stężenia masowe cząstek były około dwa razy większe. Ponadto, większe średnie stężenia liczbowe i masowe cząstek odnotowano dla pomiarów mobilnych niż dla stacjonarnych. Wyznaczone dawki dotyczące liczby i masy cząstek deponowanych w drogach oddechowych kierowców w godzinach szczytu wynosiły odpowiednio 4,8 ±2,4×109 #/h i 29,6 ±10,7 μg/h (PM10). Zarówno dla godzin szczytu, jak i poza szczytem, większe dawki deponowanych cząstek uzyskano dla wydzielonego odcinka trasy o największej intensywności ruchu. Podsumowując, otrzymane wyniki wskazują na istotność pomiarów cząstek emitowanych ze źródeł komunikacyjnych, szczególnie w kontekście narażenia uczestników ruchu drogowego na te cząstki.
EN
The aim of the presented case study analysis was to present the possibilities of using the SenseWear PRO3 Armband mobile monitor in the assessment of physical activities. During the measurement, the SenseWear PRO3 Armband recorded the following parameters: total energy expenditure [kcal], average METs (for the whole analyzed period) [-], number of steps [-], active energy expenditure [kcal], lying down duration [min], sleep duration [min], sedentary physical activity duration [min], physical activity duration [min], including moderate physical activity duration [min], vigorous physical activity duration [min] and very vigorous physical activity duration [min]. The results for chosen participant were analyzed – in various periods of time (for the 24 on-body hours session of wearing the SenseWear PRO3 Armband and the whole session), as well as for basic and broaden analysis. The graphical reports from the sessions were also presented. It was concluded that the SenseWear PRO3 Armband device is a valuable tool in everyday medical practice to specify the physical activity of individuals and to verify their declarations. For users, the SenseWear PRO3 Armband device is easy to handle, while measurement is not onerous and does not disturb typical activities
3
Content available Mobile devices in diagnostic systems
EN
The strong growth of mobile technologies with increasing quality and data rates encourage the use of mobile terminals for diagnostic purposes. It concerns the diagnostics of simple objects for everyday use as well as complex objects that often belong to a group of machines called critical objects. There is no doubt that such solutions will be expected by the operators of machinery and equipment in the near future. Solutions based on mobile technologies require appropriate preparation of diagnostic mobile applications in many aspects. The reasonable implementation of mobile devices forces the application designer to solve at least two difficult tasks. The first task relates to the design of user interface functionality and shape, taking into account a number of existing constraints, such as the screen size of mobile device, performance of the unit, applied data transmission technology and a quality of secure data channel in a mobile network. The second task is associated with the selection of optimal technology used to operate in mobile environment with detailed substantiation of the decision. The aim of this paper is to describe the basic principles which should guide the implementation of solutions enabling the user wireless access to diagnostic data of a technical object. Also basic requirements for well-designed user interface of the mobile application will be given in the paper.
PL
Silny rozwój technologii mobilnych, któremu towarzyszy podwyższanie jakości i szybkości przesyłania danych zachęca do korzystania z terminali mobilnych do celów diagnostycznych. Dotyczy to diagnostyki prostych obiektów codziennego użytku, jak również złożonych obiektów, które często należą do grupy maszyn nazywanych obiektami krytycznymi. Nie ma wątpliwości, że takie rozwiązania będą w najbliższej przyszłości oczekiwane przez operatorów maszyn i urządzeń. Rozwiązania oparte na technologiach mobilnych, wymagają odpowiedniego przygotowania diagnostycznych aplikacji przeznaczonych na urządzenia mobilne z uwzględnieniem wielu aspektów. Wdrożenie urządzeń mobilnych wymusza na projektancie aplikacji rozwiązanie co najmniej dwóch trudnych zadań. Pierwsze zadanie dotyczy projektowania funkcjonalności interfejsu użytkownika i jego postaci, biorąc pod uwagę liczbę istniejących ograniczeń, takich jak rozmiar ekranu urządzenia mobilnego, wydajność urządzenia, stosowaną technologię transmisji danych oraz jakość zabezpieczenia kanału przesyłu danych przez sieć bezprzewodową. Drugie zadanie jest związane z wyborem optymalnej technologii, która będzie użyta na urządzeniu bezprzewodowym. Celem niniejszego opracowania jest przedstawienie podstawowych zasad, które powinny przyświecać wdrażaniu rozwiązań umożliwiających użytkownikom realizację bezprzewodowej diagnostyki obiektu technicznego. W artykule przedstawione zostaną także podstawowe wymagania dla dobrze zaprojektowanego interfejsu użytkownika aplikacji mobilnej.
PL
Satelitarne systemy monitorowania pojazdów to nowoczesne narzędzia wykorzystywane w coraz większej liczbie firm transportowych. W trudnych czasach wysokiej konkurencji ułatwiają one ekonomiczne zarządzanie flotą i planowanie, pozwalają monitorować ładunki, a także poprawiają bezpieczeństwo pracy.
EN
The satellite vehicle monitoring systems are modern tools used by a growing number of transporting companies. In difficult times of tough competition, they allow for easier planning and economic management of the fleet. Additionally, they make the monitoring of the cargo possible and they improve the work safety.