Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  mikrosiatka
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In microgrid distribution generation (DG) sources are integrated parallelly for the economic and efficient operation of a power system. This integration of DG sources may cause many challenges in a microgrid. The islanding condition is termed a condition in which the DG sources in the microgrid continue to power the load even when the grid is cut off. This islanding situation must be identified as soon as possible to avoid the collapse of the microgrid. This work presents the hybrid islanding detection technique. This technique consists of both active and parametric estimation methods such as slip mode shift frequency (SMS) and exact signal parametric rotational invariance technique (ESPRIT), respectively. This technique will easily distinguish between islanding and non-islanding events even under very low power perturbations. The proposed method also has no power quality impact. The proposed method is tested with UL741 standard test conditions.
EN
Self-healing grids are one of the most developing concepts applied in electrical engineering. Each restoration strategy requires advanced algorithms responsible for the creation of local power systems. Multi-agent automation solutions dedicated for smart grids are mostly based on Prim’s algorithm. Graph theory in that field also leaves many problems unsolved. This paper is focused on a variation of Prim’s algorithm utility for a multi-sourced power system topology. The logic described in the paper is a novel concept combined with a proposal of a multi-parametrized weight calculation formula representing transmission features of energy delivered to loads present in a considered grid. The weight is expressed as the combination of three elements: real power, reactive power, and real power losses. The proposal of a novel algorithm was verified in a simulation model of a power system. The new restoration logic was compared with the proposal of the strategy presented in other recently published articles. The novel concept of restoration strategy dedicated to multi-sourced power systems was verified positively by simulations. The proposed solution proved its usefulness and applicability.
EN
In this study, the inverter in a microgrid was adjusted by the particle swarm optimization (PSO) based coordinated control strategy to ensure the stability of the isolated island operation. The simulation results showed that the voltage at the inverter port reduced instantaneously, and the voltage unbalance degree of its port and the port of point of common coupling (PCC) exceeded the normal standard when the microgrid entered the isolated island mode. After using the coordinated control strategy, the voltage rapidly recovered, and the voltage unbalance degree rapidly reduced to the normal level. The coordinated control strategy is better than the normal control strategy.
EN
This paper proposes an advanced Internet of Things (IoT) system for measuring, monitoring, and recording some power quality (PQ) parameters. The proposed systemis designed and developed for both hardware and software. For the hardware unit, three PZEM-004T modules with non-invasive current transformer (CT) sensors are used tomeasure the PQ parameters and an Arduino WeMos D1 R1 ESP8266 microcontroller isused to receive data from the sensors and send this data to the server via the internet. For the software unit, an algorithm using Matlab software is developed to send measurement datato the ThingSpeak cloud. The proposed system can monitor and analyse the PQ parameters including frequency, root mean square (RMS) voltage, RMS current, active power, and the power factor of a low-voltage load in real-time. These PQ parameters can be stored on theThingSpeak cloud during the monitoring period; hence the standard deviation in statistics of the voltage and frequency is applied to analyse and evaluate PQ at the monitoring point.The experimental tests are carried out on low-voltage networks 380/220 V. The obtained results show that the proposed system can be usefully applied for monitoring and analysing chosen PQ parameters in micro-grid solutions.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.