Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  metoda elektryczna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Geophysical characterization of contaminated sites is an important procedure in pre- and post-site remediation. It has been carried out in several contaminated sites, irrespective of differences in site geology, nature of contaminants, and prevailing hydrological conditions. Electrical prospecting methods are the most used geophysical techniques for contaminant plume mapping. Due to this widespread use, there is an increasing number of literature on the use of electrical methods directed toward contaminant plume mapping. Yet, it lacks a comprehensive framework in literature that synthesizes the methods’ concepts, applications, and limitations. In this review, we summarized the use of electrical methods (electrical resistivity, self-potential, and induced polarization) in mapping contaminant plumes and provided a synthesis of concepts, applications, and limitations. The advantages, drawbacks, and the solutions achieved so far were emphasized in this review. Some of the advantages are that electrical methods are faster, cheaper, noninvasive and provide continuous images of contaminant plumes when compared to the traditional techniques. The drawbacks highlighted include the non-uniqueness of the vertical electrical sounding (VES), distortion effect of the 2D electrical resistivity tomography (ERT) and huge cost of 3D ERT data acquisition. We also highlighted other geophysical methods that could be used to map contaminant plumes. Conclusively, this review paper identified future research direction and offers insight into emerging issues associated with these techniques for better modeling of contaminated sites.
EN
Results of energy efficiency of rail induction heating testing are presented in this paper. Methods of snow and ice removal from turnouts currently in application are not economical in terms of energy consumption. Ways of saving energy must be explored, therefore. Induction heating described in this paper is one of those. The U type of heater was employed in laboratory testing of rail induction heating. Application of an inductor in the form of a coil wound around a ferrite core showed maximum energy efficiency. A DC/AC converter including a current inverter and a parallel resonant circuit supplied power to the inductor was applied. The temperature of the rail during induction heating and natural cooling was presented. The results support the method of rail induction heating in railroad turnouts.
PL
Artykuł przedstawia wyniki badań grzania indukcyjnego szyny kolejowej. Stosowane obecnie metody służące do usuwania śniegu i oblodzeń z rozjazdów kolejowych nie są energooszczędne. Metoda elektryczna jest łatwa w montażu i wygodna w eksploatacji, natomiast pociąga za sobą ogromne koszty zużycia energii. W związku z tym zachodzi potrzeba poszukiwania sposobów oszczędzania energii. Jedną z nich, opisaną w artykule, jest metoda grzania indukcyjnego. Przedstawiono temperatury szyny podczas ogrzewania indukcyjnego i naturalnego chłodzenia. Największą efektywność energetyczną w obrębie stopki szyny uzyskano przy zastosowaniu wzbudnika w kształcie cewki nawiniętej na rdzeniu ferrytowym. Do zasilania wzbudnika użyto przekształtnika rezonansowego DC/AC z falownikiem prądu i równoległym obwodem rezonansowym. Uzyskane wyniki badań wykazują przydatność metody grzania indukcyjnego szyny w rozjazdach kolejowych.
PL
W artykule przedstawiono metodykę pomiarów wyładowań niezupełnych oraz ich znaczenie w diagnostyce technicznej układów izolacyjnych. W szczególności opisano metodę elektryczną pomiaru wyładowań niezupełnych – jako metodę autonomiczną oraz jako część, opracowanej na Wydziale Elektrycznym Politechniki Śląskiej, zespolonej metody oceny wyładowań niezupełnych. Przedstawione zostały również wyniki pomiarów wyładowań niezupełnych w wybranych układach izolacyjnych oraz innowacyjna (opracowana w Instytucie Elektroenergetyki i Sterowania Układów) metoda interpretacji uzyskiwanych wyników.
EN
The article presents the methods of partial discharge measurements and their importance in the diagnosis of technical insulation systems. In particular, the electrical method of the partial discharge measurement has been described. This is an autonomous method of measurement, but it also constitutes a part of the complex method of the partial discharge assessment, developed in Electrical Faculty of Silesian University of Technology. Results of partial discharge measurements in selected insulation systems are also presented as well as innovative method of result interpretation, which has been developed in the Institute of Power Systems and Control.
PL
W artykule zaprezentowano wstępne wyniki badań wykonanych na modelowych źródłach wnz w celu ustalenia czy możliwe jest zwiększenie funkcjonalności metody emisji akustycznej (EA) tak aby uzyskiwać za jej pomocą informację o poziomie ładunku pozornego lub innego parametru mierzonego metodą elektryczną.
EN
The article presents the preliminary results of tests carried out on the modeled PD sources in order to determine whether it is possible to increase the functionality of the acoustic emission methods (AE) to obtain for its help information about the value of apparent charge or other parameter measured by electric method.
PL
Artykuł przedstawia doświadczenia autorów z zakresu pomiarów intensywności wyładowań niezupełnych metodą elektryczną w transformatorach energetycznych przy wykorzystaniu cyfrowego miernika wyładowań niezupełnych DDX 7000. Przedstawiono układy stosowane przy pomiarach oraz problemy związane z pomiarami wykonywanymi w warunkach przemysłowych.
EN
The article presents the expierences of the authors in the field of the measurements of the intensity of partial discharges in power transformers using digital partial discharge detector DDX 7000. The measurement systems and the problems connected with the measurements performed in industrial conditions are also presented.
PL
W artykule przedstawiono wyniki pomiarów wyładowań niezupełnych (wnz) w olejowym transformatorze energetycznym WN/SN. Wyładowania mierzono metodą elektryczną. Analizę wyników pomiarów wykonano, uwzględniając m.in. wybrane rozkłady fazowe, amplitudowofazowe i intensywności wnz. Na podstawie uzyskanych wyników analizy podjęto próbę lokalizacji źródeł wnz. Poprawność takiego niekonwencjonalnego zastosowania metody elektrycznej zweryfikowano przy pomocy wyników pomiarów uzyskanych metodą akustyczną, którą zastosowano jednocześnie z metodą elektryczną. Badania prowadzono na transformatorze przeznaczonym do remontu.
EN
The research on partial discharge in oil filled power transformer is presented in the paper. The measurements were proceeded with ultra wide band discharge analyzer. The analysis is based on chosen PD distributions and other quantities. Basing on the analysis there was an attempt to location of PD sources. The unconventional approach was verified by acoustic emission method which was also involved in measurements of partial discharge to locate PD sources.The reasearch was proceeded on the power transformer qualified to repair.
7
Content available remote Nieniszcząca ocena skuteczności napraw konstrukcji betonowych
EN
Changes in characteristics of electric and magnetic conductivrty of a ground center caused by liquid flow from an injured pipeline. Electric methods - electro-resistance measuremenls, method of gradient potenlial. Electromagnetic methods - finding the breakdown place with the useof georadar. Advanlagesof each method.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.