The methodology of calculations of boilers furnace chambers using CKTI and zone methods was presented. The results of numerical calculations of the OP-210 boiler furnace chamber using CKTI method were compared to the results avaiable from literature. Next it was compared to the results obtained from zone method also. Good accuracy of the presented comparisons allows to apply written computational software to calculate furnace chambers.