Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  metformin
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The present work aimed to develop and validate a simple, rapid, sensitive, accurate, and precise method for simultaneous determination of metformin hydrochloride and vildagliptin in tablet and biological samples. Isocratic elution of both the analytes was performed at 35 °C by injecting 20 μL into Thermo Hypersil ODS C18 column (5 μm, 4.6 mm× 250 mm), while the flow rate was set to 0.8 mL/min. The mobile phase comprised of methanol, acetonitrile, and phosphate buffer (5:30:65, v/v, pH 3.5), and wavelength was selected at 212 nm. The overall run time per sample was 7.0 min with a retention time of 3.36 and 5.41 min for metformin hydrochloride and vildagliptin, respectively. The calibration curve was linear from 10–140 μg/mL for metformin and 1–14 μg/mL for vildagliptin with a coefficient of determination (R2) ≤ 0.9919, while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.13 and 0.97%, respectively. Force degradation studies indicated a complete separation of the analytes in the presence of their degradation products providing a high degree of method specificity. The proposed reversed-phase high-performance liquid chromatography (RP-HPLC) method was demonstrated to be simple and rapid for the determination of metformin hydrochloride and vildagliptin in commercially available tablet and biological samples providing recoveries ranged between 100.13–100.29%.
EN
An isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method has been developed for rapid and simultaneous separation and estimation of 3 antidiabetic drugs, namely, metformin, pioglitazone, and glimepiride, in human plasma within 3 min. Separation was carried out on a MAGELLEN 5U C18 (5 μm, 150 mm × 4.60 mm) using a mobile phase of MeOH–0.025 M KH2PO4 adjusted to pH 3.20 using ortho-phosphoric acid (85:15, v/v) at ambient temperature. The flow rate was 1 mL/min, and the maximum absorption was measured at 235 nm. The retention time of metformin, pioglitazone, and glimepiride was noted to be 1.24, 2.32, and 2.77 min, respectively, indicating a very short analysis time compared to that of other reported methods. Also, limits of detection were reported to be 0.05, 0.26, and 0.10 μg/mL for metformin, pioglitazone, and glimepiride, respectively, showing a high degree of method sensitivity. The method was then validated according to the FDA guidelines for the determination of the three drugs clinically in human plasma, in particular, regarding pharmacokinetic and bioequivalence simulation studies.
3
Content available remote Metformina - cudowny lek?
EN
Escherichia coli K-12 GFP-based bacterial biosensors allowed the detection of cytotoxic and genotoxic effect of anticancer drug– cyclophosphamide and antidiabetic drug – metformin in PBS buffer and surface water. Experimental data indicated that recA::gfpmut2 genetic system was sensitive to drugs and drugs mixture applied in experiment. RecA promoter was a good bioindicator in cytotoxic and genotoxic effect screening of cyclophosphamide, metformin and the mixture of the both drugs in PBS buffer and surface water. The results indicated that E. coli K-12 recA::gfp mut2 strain could be potentially useful for first-step screening of cytotoxic and genotoxic effect of anticancer and antidiabetic pharmacist residues in water. Next steps in research will include more experimental analysis to validate recA::gfpmut2 genetic system in E. coli K-12 on different anticancer drugs.
EN
A simple, rapid, precise, and accurate, stability-indicating reversed phase high performance liquid chromatographic method was developed and validated for simultaneous determination of metformin HCl and repaglinide. The chromatographic separation was achieved on YMC Pack AM ODS (5 μm, 250 mm length × 4.6 mm i.d.) column at a detector wavelength of 210 nm, using an isocratic mobile phase consisting of methanol and 10 mM potassium dihydrogen phosphate buffer (pH 2.5) in a ratio of 70:30 v/v at a flow rate of 1 mL min-1. The retention times for metformin and repaglinide were found to be 2.6 and 11.3 min, respectively. The drugs were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. Validation of the method was carried out as per International Conference on Harmonization (ICH) guidelines. Linearity was established for metformin and repaglinide in the range of 5–200 μg mL-1 and 1–200 μg m-1. L, respectively. The limits of detection were 0.3 μg mL-1 and 0.13 μg mL-1 for metformin and repaglinide, respectively. The method was found to be specific and stability-indicating as no interfering peaks of degradants and excipients were observed. The proposed method is hence suitable for application in quality-control laboratories for quantitative analysis of both the drugs individually and in combination, since it is simple and rapid with good accuracy and precision.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.