Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  membrany filtracyjne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper uses a simple model to present the effects of viscosity and surface tension on the basic parameters of the biological microparticle filtration process. A single filtration membrane with a uniform transmission structure in 2D space was used for the purposes of this analysis. The filtration system relations are described for the threshold filtration force, maximum and minimum height of the filtered liquid to guarantee stable filtration in a gravity field, and the duration of the process and forces affecting the microparticles during filtration. Based on these relations, the summary shows sample calculations for the base model of negative filtration of biological particles.
PL
W artykule przedstawiono wpływ lepkości i napięcia powierzchniowego na podstawowe parametry procesu filtracji mikrocząstek biologicznych. Do analizy wykorzystano pojedynczą membranę filtracyjną o jednorodnej strukturze transmisji w przestrzeni 2D. Dla powyższego układu filtracji opisano zależności określające graniczną siłę filtracji, maksymalną i minimalną wysokość filtrowanej cieczy gwarantującą stabilne warunki procesu filtracji w polu grawitacyjnym, a także zależności opisujące czas procesu i siły działające na mikrocząstki w procesie filtracji. W podsumowaniu publikacji, na podstawie tych zależności przedstawiono przykładowe obliczenia dla bazowego modelu negatywowej filtracji cząstek biologicznych.
PL
W artykule przedstawiono model filtra do separacji wymiarowej mikrocząstek biologicznych z płynów ustrojowych, w tym między innymi krwi obwodowej. W modelu wykorzystano pojedyncze sito membranowe o jednorodnej strukturze transmisji w przestrzeni 2D. Ze względu na zakładaną przeżywalność cząstek biologicznych, prezentowany model ograniczono do zawężonych warunków filtracji, gwarantujących zachowanie aktywności biologicznej tych cząstek. W prezentowanym modelu proces filtracji przebiega w polu grawitacyjnym bez udziału zewnętrznych sił wymuszających lub hamujących proces filtracji. Na podstawie tego modelu wyznaczono podstawowe zależności opisujące wymagane warunki procesu filtracji, takie jak czas filtracji i wewnętrzne siły wymuszające migrację cząstek w filtrowanym płynie ustrojowym. Określono podstawowe zależności między wysokością słupa filtrowanego płynu, czasem trwania procesu i średnim wydatkiem procesu filtracji. Na podstawie tych danych określono kierunki dalszych prac nad doskonaleniem prezentowanego modelu filtracji mikrocząstek biologicznych na potrzeby wzbogacania wybranych frakcji biologicznych.
EN
The paper presents a model of a microfiltration filter for separation of biological microparticles from body fluids, including peripheral blood. The model used a single membrane filter with a homogeneous 2D transmission structure. In the model, the individual sieve with a uniform transmission structure in 2D space was applied. Because of the required survival of biological particles, the presented model was limited to the narrow filtration conditions that guarantee biological activity of these particles. In this model, the filtration process proceeds in the gravitational field without the involvement of external forces forcing or inhibiting the filtration process. Based on this model there were given basic dependencies describing the required filtration process conditions, such as filtration time and internal forces for particle migration in the filtered body fluid. The basic relationships between the height of the filtered column, duration of the process, and average fluid expenditure of the filtration process for different shapes of the channels molecular drainage lines filter have been determined. Based on this data, the directions of further works on improving the presented model of molecular filtration of biological particles for enriching selected biological fractions have been described.
PL
Badanie Integralności filtrów służy do identyfikacji wielkości porów filtra odpowiednio do standardów określanych przez producenta. Najbardziej popularnymi metodami badania integralności są testy: Bubble Point oraz test dyfuzyjny. Badanie integralności membran hydrofilowych jest oparte na przejściu gazów przez zwilżoną wcześniej membranę. Wartość Bubble Point jest generalnie używana do opisu średnicy porów membrany. Test dyfuzyjny to wartość przepływu powietrza, będąca funkcją ciśnienia transmembranowego. Testy na integralność nie definiują średnicy porów w sposób bezpośredni, tylko relacje pomiędzy wielkością cząstek zatrzymywanych przez odpowiedni filtr. Membranowe filtry, przed zbadaniem integralności, powinny być dobrze zwilżone oraz powinna być przeprowadzona dokładna kontrola temperatury.
EN
Integrity testing serves to identify the pore size rating of the filter in accordance with the filter manufactures standards. The most popular testing methods are Bubble Point Test and Diffusion Test. The integrity testing of hydrophilic membranes is based on air (gas) passage through wetted filters. Bubble Point numbers are generally used to identify the presumed pore size rating of a membrane. The rate of diffusive airflow is a function of the transmembrane pressure differential. Integrity test values do not define pore size dimensions but relate to the size particles the filter retain. Membrane filters before integrity must be fully wetted and temperature control of the system must be perform.
first rewind previous Strona / 1 next fast forward last