The enzymatic synthesis of a highly hydrophobic product (dipeptide precursor) in which the reaction is accompanied by the mass transfer of the reaction product to the organic phase and the substrates to the water phase is considered. Equations describing both continuous and batch processes are formulated. The range of variability in the operating parameters of such a bioreactor is specified, and the correlations reported in the literature to describe mass transfer in the membrane contactor are validated. The proposed process was verified experimentally, and good agreement between the determined and calculated concentrations was obtained in both phases.
PL
Odzyskiwanie alkoholu z rozcieńczonych roztworów wodnych jest procesem wysoko energochłonnym. W celu obniżenia kosztów do zatężania rozcieńczonych roztworów alkoholi wykorzystuje się procesy membranowe, między innymi ekstrakcję membranową. W pracy przedstawiono wyniki badań procesu zatężania rozcieńczonych wodnych roztworów etanolu w kontaktorze membranowym z zastosowaniem cieczy jonowej. W przeprowadzonych eksperymentach wykorzystano kontaktor membranowy z mikroporowatymi membranami kapilarnymi stanowiącymi barierę między roztworem surowym a ekstrahentem, a jednocześnie zapewniającymi dużą powierzchnię wymiany masy. W procesie jako ekstrahenta użyto cieczy jonowej wykazującej selektywność w stosunku do etanolu. Omówiono wyniki badań procesu zatężania roztworów etanolu o stężeniach od 1 do 5% masowych i natężeniach przepływu nadawy zmienianych w zakresie 1-8 dm3/h.
EN
Recovery of alcohol from diluted aqueous solutions is a highly energy-intensive process. In order to reduce the costs of concentration of alcohols, membrane processes (including membrane extraction) are used. This paper reports the results of ethanol concentration from diluted water solutions using a membrane contactor with ionic liquid. The studies were performed using a membrane contactor with microporous capillary membranes. The membrane is a barrier between the raw and the extractant solution, also providing a large mass transfer area. In the process ionic liquids having different selectivity to ethanol as extractant were used. Results were obtained for concentration of ethanol solutions in the range of 1 to 5 wt.% and for the different feed flow rates ranges from 1 to 8 dm3/h.
EN
Recovery of alcohols from diluted aqueous solutions is highly energy-intensive. In order to reduce the costs of concentration of alcohols, membrane processes (including membrane extraction) are used. This paper reports the results of ethanol concentration from diluted aqueous solutions using a hollow fiber membrane contactor with ionic liquid. The studies were performed using a contactor with microporous hollow fiber membranes. The membrane creates a barrier between the feed and extracting solvent, also providing a large mass transfer area. In the process, selected ionic liquid presenting different selectivity towards ethanol was used as extractant. The experiments were performed with feed concentrations of ethanol ranging from 1 to 5 wt.% and various feed flow rates ranging from 1 to 8 dm3/h.
PL
Odzyskiwanie alkoholu z rozcieńczonych roztworów wodnych jest procesem wysoko energochłonnym. W celu obniżenia kosztów do zatężania rozcieńczonych roztworów alkoholi wykorzystuje się procesy membranowe, między innymi ekstrakcję membranową. W pracy przedstawiono wyniki badań procesu zatężania rozcieńczonych wodnych roztworów etanolu w kontaktorze membranowym z zastosowaniem cieczy jonowej. W przeprowadzonych eksperymentach wykorzystano kontaktor membranowy z mikroporowatymi membranami kapilarnymi stanowiącymi barierę między roztworem surowym a ekstrahentem i jednocześnie zapewniającymi dużą powierzchnię wymiany masy. W procesie jako ekstrahenta użyto cieczy jonowej wykazującej selektywność w stosunku do etanolu. Omówiono wyniki badań procesu zatężania roztworów etanolu o stężeniach 1 do 5% masowych i natężeniach przepływu nadawy zmienianych w zakresie od 1 do 8 dm3/h.
PL
Celem pracy było wyznaczenie krzywych równowagowych dla lotnych związków organicznych, aby rozpoznać możliwości prowadzenia procesu zintegrowanego: reekstrakcji z biodegradacją. Określono również szybkość transportu masy benzenu w kontaktorze membranowym.
EN
The aim of this study was to determine equilibrium curves for volatile organic compounds, subsequently used for the recognition of possibilities of carried out reextraction and biodegradation as the integrated process. The mass transfer rate of benzene in a membrane contactor was also determined.
EN
The knowledge about membrane contactors is growing rapidly but is still insufficient for a reliable designing. This paper presents a new type of membrane contactors that are integrated with one of the following ways of separation by using absorbents, micelles, flocculants, functionalized polymers, molecular imprints, or other methods that are based on aggregation. The article discusses methods for designing multi-stage cascade, usually counter-current. At every stage of this cascade, relevant aggregates are retained by the membrane, while the permeate passes freely through membrane. The process takes place in the membrane boundary layer with a local cross-flow of the permeate and the retentate. So the whole system can be called a cross-counter-current. The process kinetics “k” must be coordinated with the permeate flux “J” and the rate of surface renewal of the sorbent on the membrane surface, s. This can be done by using ordinary back-flushing or relevant hydrodynamic method of sweeping, such as: turbulences, shear stresses or lifting forces. A surface renewal model has been applied to adjust the optimal process conditions to sorbent kinetics. The experimental results confirmed the correctness of the model and its suitability for design of the new type of contactors.
EN
Biological regeneration of water and organic sorbents used in the absorption of hydrophilic and hydrophobic pollutants, respectively, was studied. In both cases biodegradation takes place in a membrane bioreactor. In the case of organic sorbents regeneration of the biodegradation process is integrated with the extraction of a given pollutant to water phase. In experiments carried out in this work, the proposed systems were tested using a strain of Pseudomonas fluorescens. For hydrophilic compounds experiments were performed using alcohols (1-butanol and 2-propanol) as model substrates. Applying the mathematical model of a membrane bioreactor elaborated previously, the values of pollutant concentration were determined and positively verified in the experiments. This system of water sorbent regeneration is fully satisfying. The process of biodegradation integrated with extraction was analysed on the basis of model compounds such as benzene and toluene. The study confirmed a possibility of organic sorbent (silicone oil) regeneration. However, due to a very high partition coefficient of benzene or toluene between the organic and aqueous phases, the process could be considered only for the case of their high concentrations in the gas directed to absorption.
EN
The aim of this work was to investigate the applicability of membrane distillation for ammonia removal from its aqueous solutions. The hollow-fiber, hydrophobic microfiltration membrane module was applied in order to assess its performance. The effects of different operating parameters on ammonia removal from aqueous solutions of different concentrations were investigated. Ammonia was absorbed in strong inorganic acid, in all tests that were taken.
PL
Przetestowano możliwość usuwania amoniaku z jego wodnych roztworów za pomocą hydrofobowego, mikrofiltracyjnego (MF) modułu membranowego wyposażonego w membrany kapilarne. Określono wpływ temperatury oraz początkowego stężenia amoniaku na szybkość jego usuwania z wodnego roztworu. W obu analizowanych przypadkach amoniak został zaabsorbowany w mocnym kwasie nieorganicznym.
PL
Oczyszczanie gazów procesowych i powietrza stanowi istotny aspekt działań zmierzających do ograniczenia emisji zanieczyszczeń do środowiska. Kluczowym zagadnieniem dla rozwiązania w/w problemu jest poszukiwanie nowych rozwiązań procesowych i aparaturowych w zakresie wychwytu zanieczyszczeń ze strumieni gazu. Poniższa praca przedstawia wyniki badań nad absorpcją lotnych związków organicznych (ŁZO) z wykorzystaniem kapilarnego kontaktora membranowego. Badania kinetyki absorpcji w układzie aceton/woda w kapilarnym kontaktorze membranowym pozwoliły na wyznaczenie współczynników wnikania masy po stronic gazu i cieczy a tym samym na określenie optymalnych warunków pracy absorbera membranowego.
EN
The air and flue gases purification is an essential aspect of decreasing pollutants emission. A key issue to solve this problem is a search for new processes and apparatuses designs in the field of gas stream impurities capturing. The paper presents research results dealing with the absorption of volatile organic compounds in a membrane capillary contactor. The acetone/water absorption kinetics' experiments with the use of membrane capillary contactor allowed one to determine the gas and liquid side mass transport coefficients, and therefore enabled the selection of optimal operating conditions for membrane absorption process.
PL
Przedstawiono możliwości zastosowania kontaktorów membranowych do usuwania p-krezolu z wody. Jako kontaktor membranowy w części doświadczalnej zastosowano kapilarny moduł ultrafiltracyjny z membraną polisulfonową. W celu zwiększenia wydajności procesu ekstrakcji zastosowano solubilizację p-krezolu w micelach utworzonych przez dwa związki powierzchniowo czynne - CTAB i SDS. Wyznaczono stałe kinetyczne procesu i opory dyfuzyjne membrany.
EN
The possibility of various applications of membrane contactors for removal of organic components from water have been presented. In the experiments, as a membrane contactor the UF hollow fiber module with polysulphone membrane has been applied. To enhance the process efficiency, the solubilization of p-cresol molecules in micelles created by surfactants CTAB and SDS was applied. The kinetic constants and diffusion resistance of the membrane were determined.
EN
The paper presents a pilot active membrane contactor system (AMCS) description and experimental results for air dehumidification. Triethyleneglycol was used as a hygroscopic liquid carrier. Polydimethylsiloxane based membranes (Lestosil) were used in a spiral wound membrane contactor. The experiments with AMCS demonstrated effective air-drying under a high ratio-feed gas flux/liquid carrier flux (10²-10³). The developed contactor system allows to achieve air dehumidification up to Tdew point= –20 °C.
first rewind previous Strona / 1 next fast forward last